HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 68
PDC failed to read the HV Flag in the Partition Configuration Data. Probable Cause
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
Event ID Event Severity 9678 Error 9681 Error 9682 Warning 9685 Error 9695 Error 9696 Error 9697 Error 9698 Error 9700 Error 9701 Error 9706 Warning 9707 Warning Event Description The clock ratio reported by manageability does not match the actual clock ratio. Probable Cause: This is a hardware error and it is fatal. WBEM EventID: 2687. WBEM ProviderName: FPL_IndicationProvider. Manual override of fatal stop boot condition. Probable Cause: The user has initiated manual O/S boot despite the existence of a error. Recommended Action: Correct the error condition (see output of 'INFO WARNING' EFI shell command), reboot the system, and then initiate O/S boot. WBEM EventID: 985. WBEM ProviderName: FPL_IndicationProvider. Firmware unable to relocate VGA BIOS. Probable Cause: Most likely there is a permanent memory error in the VGA BIOS region (physical address 0xc0000 - 0xdffff). Recommended Action: Replace the DIMM causing the permanent memory error in the VGA BIOS region. The PDT reports which DIMM is causing errors in the physical address range 0xc0000 - 0xdffff. WBEM EventID: 986. WBEM ProviderName: FPL_IndicationProvider. The Compatibility Matrix stored in NVRAM has a checksum error. Probable Cause: NVRAM has become corrupt. Restore from a backup. WBEM EventID: 987. WBEM ProviderName: FPL_IndicationProvider. PDC failed its attempt to get default RDR values. Probable Cause: Hardware problem with the CPU. Recommended Action: Contact HP Support to confirm the CPU is functioning properly. WBEM EventID: 1811. WBEM ProviderName: FPL_IndicationProvider. PDC could not read current RDR values of the executing CPU. Probable Cause: Hardware problem with the CPU. Recommended Action: Contact HP Support to confirm the CPU is functioning properly. WBEM EventID: 1812. WBEM ProviderName: FPL_IndicationProvider. PDC failed reading a specific value from its own copy of the RDRs. Probable Cause: problem on cell wherein PDC could not properly access memory Recommended Action: Contact HP support to troubleshoot cell board. Probable Cause: a non-existent/non-accessible register was specified by software. Recommended Action: Contact HP support for possible PDC upgrade. WBEM EventID: 1813. WBEM ProviderName: FPL_IndicationProvider. PDC failed reading a specific value from its own copy of the RDRs. Probable Cause: problem on cell wherein PDC could not properly access memory Recommended Action: Contact HP support to troubleshoot cell board. WBEM EventID: 1814. WBEM ProviderName: FPL_IndicationProvider. PDC failed attempting to update ZLCO and PREFETCH RDR settings. Probable Cause: Could not update CPU settings Recommended Action: Contact HP support to troubleshoot cell board and CPU. WBEM EventID: 1815. WBEM ProviderName: FPL_IndicationProvider. PDC failed to read the HV Flag in the Partition Configuration Data. Probable Cause: An error occurred which prevented the complex profiles from being distributed properly. Recommended Action: Create and distribute a new complex profile using ParMgr on a functional partition in the complex. Restore the last complex profile using the 'CC' command from the MP, then use ParMgr to create a new complex profile. Generate a genesis complex profile using the 'CC' command from the MP, then use ParMgr to create a new complex profile. WBEM EventID: 1816. WBEM ProviderName: FPL_IndicationProvider. Failed to get the configured set from the Complex Profiles A and C. Probable Cause: A hardware problem exists with MP or PDHC hardware. Recommended Action: Contact HP Support to confirm the MP and PDHC are functioning properly. WBEM EventID: 993. WBEM ProviderName: FPL_IndicationProvider. No possible core cells were found in the configured set. Probable Cause: most likely a configuration problem, Recommended Action: check to ensure a valid core cell is configured to be in the partition. WBEM EventID: 994. WBEM ProviderName: FPL_IndicationProvider. 68 WBEM Provider Event Tables