HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 74
Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
Event ID Event Severity 10116 Error 10132 Error 10159 Warning 10209 Warning 10272 Error 10273 Error 10343 Error 10351 Error 10357 Warning 10358 Warning 10361 Error 10375 Warning Event Description The NVRAM service was unable to satisfy an NVRAM allocation request. Probable Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear NVRAM and reset. WBEM EventID: 2499. WBEM ProviderName: FPL_IndicationProvider. The RTC not updating its internal time registers. Probable Cause: Bad RTC chip on the PDH daughtercard. Recommended Action: Replace PDH daughtercard. WBEM EventID: 2512. WBEM ProviderName: FPL_IndicationProvider. Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has occurred on the MX2 module and PAA firmware has halted. Recommended Action: Contact your HP support personnel. WBEM EventID: 2740. WBEM ProviderName: FPL_IndicationProvider. fabric API is about to open the a link going out of the local cell. Probable Cause: An error prevented the use of a fabric link. Recommended Action: Collect IPMI event logs for more information regarding the failure. Contact your HP Support Representative to investigate the fabric subsystem. WBEM EventID: 2914. WBEM ProviderName: FPL_IndicationProvider. An Arches fabric CSR read was unsuccessful because of a timeout. Probable Cause: An error occurred while reading a hardware register. Other events should detail the error. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2908. WBEM ProviderName: FPL_IndicationProvider. An Arches fabric CSR write was unsuccessful. Probable Cause: An error occurred while writing a hardware register. Other events should detail the error. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2909. WBEM ProviderName: FPL_IndicationProvider. The event data details the error that was encountered. Probable Cause: A fabric error occurred while preparing for rendezvous Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2910. WBEM ProviderName: FPL_IndicationProvider. The maximum memory supported by this system has been exceeded. Probable Cause: Too much memory has been installed in the system. Recommended Action: Remove DIMMs to get the total memory size below the amount of memory returned in the data field. WBEM EventID: 2911. WBEM ProviderName: FPL_IndicationProvider. Failed to delete a bad port while routing the fabric. Data field indicates return status. Probable Cause: Experienced an error while routing the fabric. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 4848. WBEM ProviderName: FPL_IndicationProvider. Failed to delete an edge that was found to be bad during routing. Probable Cause: Experienced an error while routing the fabric. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 4849. WBEM ProviderName: FPL_IndicationProvider. A command to the memory buffer chip failed to complete. Probable Cause: System firmware did not get a completion status from a command to a memory buffer chip. Recommended Action: Contact HP support. WBEM EventID: 2917. WBEM ProviderName: FPL_IndicationProvider. The Arches Fabric function ArfIsCsrRouteTraversable was called for a back-to-back system. This is unsupported, ArfIsCsrRouteTraversable should only be called for systems with crossbars. No data. Probable Cause: An unsupported fabric call was made. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2918. WBEM ProviderName: FPL_IndicationProvider. 74 WBEM Provider Event Tables