HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 14
PSR fetch failure. Probable Cause: SFW tried to read the Processor Status Register
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Event ID Event Severity 5040 Error 5041 Error 5042 Error 5045 Error 5048 Error 5049 Error 5050 Error 5051 Error 5052 Error 5053 Warning 5054 Error 5055 Error 5056 Warning 5057 Warning 5058 Warning Event Description Could not allocate memory for EFI image. Probable Cause: SFW could not allocate enough memory for EFI image. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 217. WBEM ProviderName: FPL_IndicationProvider. EFI image corrupted. Probable Cause: EFI image is corrupted. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 218. WBEM ProviderName: FPL_IndicationProvider. EFI not in fit table. Probable Cause: EFI image is not in FIT. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 219. WBEM ProviderName: FPL_IndicationProvider. NVRAM test fail. Probable Cause: NVM is corrupted or bad. Recommended Action: Clear NVM, if problem persists contact your HP representative for support. WBEM EventID: 220. WBEM ProviderName: FPL_IndicationProvider. EFI Rom size bad. Probable Cause: EFI image is corrupt. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 221. WBEM ProviderName: FPL_IndicationProvider. EFI Rom checksum error. Probable Cause: EFI image is corrupt. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 222. WBEM ProviderName: FPL_IndicationProvider. External interruption nest limit exceeded. Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 223. WBEM ProviderName: FPL_IndicationProvider. External interrupt not serviced. Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 224. WBEM ProviderName: FPL_IndicationProvider. Ext int taken. Probable Cause: An external interrupt has been taken. Recommended action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 225. WBEM ProviderName: FPL_IndicationProvider. Forward Progress Log (FPL) access failed. Probable Cause: FPL access has failed, possibly due to BMC communication interruption. SFW will not send any events to the FPL until the system is rebooted. Recommended Action: Reboot or update System and BMC FW. If problem persists contact your HP representative for support. WBEM EventID: 226. WBEM ProviderName: FPL_IndicationProvider. PSR fetch failure. Probable Cause: SFW tried to read the Processor Status Register before the CPU data structure has been setup. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 227. WBEM ProviderName: FPL_IndicationProvider. Cell halt. Probable Cause: Internal Error. Recommended action: contact your HP representative for support. WBEM EventID: 228. WBEM ProviderName: FPL_IndicationProvider. CPU PAL incompatible with cpu. Probable Cause: Incompatible PAL. Recommended Action: Update SFW or change processors. WBEM EventID: 229. WBEM ProviderName: FPL_IndicationProvider. Slave is incompatible with monarch. Probable Cause: Incompatible processors. Recommended Action: Replace processors. WBEM EventID: 230. WBEM ProviderName: FPL_IndicationProvider. Interrupt clear failure. Probable Cause: Interrupt clear failed. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 231. WBEM ProviderName: FPL_IndicationProvider. 14 WBEM Provider Event Tables