HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 23
If assistance is required, contact the HP Support Center. WBEM EventID: 355. WBEM
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Event ID Event Severity 5280 Error 5335 Warning 5354 Error 5359 Error 5360 Error 5361 Error 5365 Error 5366 Error 5376 Error 5380 Error 5383 Error 5403 Error 5404 Warning 5405 Warning 5406 Warning Event Description Unexpected return to SAL_INIT. Probable Cause: SAL_INIT has been unexpectedly returned to. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 348. WBEM ProviderName: FPL_IndicationProvider. Firmware is adding a DEGRADED cpu node to the device tree. Probable Cause: A CPU that is not fully functional is installed in the cell board. Recommended Action: Replace cpu indicated in data field of event. WBEM EventID: 349. WBEM ProviderName: FPL_IndicationProvider. PD rendezvous will fail do to a Firmware Tree error. Probable Cause: Decode the ASCII string in the data field to determine what resource is missing. Examine earlier chassis codes to determine why that resource is unavailable. WBEM EventID: 350. WBEM ProviderName: FPL_IndicationProvider. The current cell is not configured as part of the expected set. Probable Cause: A bad complex profile exists. Correct and redistribute. WBEM EventID: 351. WBEM ProviderName: FPL_IndicationProvider. A remote CSR could not be read. Probable Cause: Either a hardware connection problem exists, or fabric was unable to be routed. Verify hardware and reset. WBEM EventID: 352. WBEM ProviderName: FPL_IndicationProvider. The current cell is too late to rendezvous with other cells. Probable Cause: This cell took to long completing previous steps to rendezvous. A bad complex profile could also cause this problem. WBEM EventID: 353. WBEM ProviderName: FPL_IndicationProvider. The current cell detected incompatible CPUs on another cell. Probable Cause: Mixed CPU types are installed in the same partition. Remove them. WBEM EventID: 354. WBEM ProviderName: FPL_IndicationProvider. Current cell was too slow creating the local rendezvous set. Probable Cause: Cell too slow. Could be bad hardware. Check for other errors and reset. Recommended Action: If assistance is required, contact the HP Support Center. WBEM EventID: 355. WBEM ProviderName: FPL_IndicationProvider. Reporting cell was not included in the global cell set. Probable Cause: Fabric problem, Connection problem or timing problem. Reset the PD. WBEM EventID: 356. WBEM ProviderName: FPL_IndicationProvider. No Core Cell can be selected in the PD. Probable Cause: No cells have a functioning core IO card. Add a core IO card to a cell in the PD and reset. WBEM EventID: 357. WBEM ProviderName: FPL_IndicationProvider. Firmware was unable to notify utilities of the core cell number. Probable Cause: Communication with utilities is broken. Check for earlier errors or NVRAM problems. WBEM EventID: 358. WBEM ProviderName: FPL_IndicationProvider. Fabric code unable to find a needed service provider. Probable Cause: The registry is corrupt or the ROM is incomplete. WBEM EventID: 359. WBEM ProviderName: FPL_IndicationProvider. Error in a fabric Port. Probable Cause: Reset. WBEM EventID: 360. WBEM ProviderName: FPL_IndicationProvider. Parity error detected on read from fabric. Probable Cause: Hardware problem. Check connections and reset. WBEM EventID: 361. WBEM ProviderName: FPL_IndicationProvider. Error writing to Fabric. Probable Cause: Bad hardware. WBEM EventID: 362. WBEM ProviderName: FPL_IndicationProvider. Platform Events 23