Failed to read a XBC Remote Routing register. Probable Cause: Fabric Access Failure
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Event ID Event Severity 9469 Warning 9470 Warning 9471 Error 9472 Error 9473 Error 9474 Error 9475 Error 9476 Error 9477 Error 9479 Warning 9480 Warning 9481 Warning 9482 Warning Event Description Failed to read the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 948. WBEM ProviderName: FPL_IndicationProvider. Failed to write the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 949. WBEM ProviderName: FPL_IndicationProvider. Failed to read the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 1777. WBEM ProviderName: FPL_IndicationProvider. Failed to write the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 1778. WBEM ProviderName: FPL_IndicationProvider. This cell encountered too many broken crossbar links. Probable Cause: Broken fabric links, Recommended Action: Check XBC, Backplane, Flex Cables, look for additional chassis codes to describe the problem. WBEM EventID: 952. WBEM ProviderName: FPL_IndicationProvider. Failed to read the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 1779. WBEM ProviderName: FPL_IndicationProvider. Failed to write the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 1780. WBEM ProviderName: FPL_IndicationProvider. Failed to read the XBC CSR that marks the port route arounds. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 1781. WBEM ProviderName: FPL_IndicationProvider. Could not traverse the PIOB route to the remote XBC. Probable Cause: Broken Crossbar Link Recommended Action: Contact HP Support personnel to check the XBC, Backplane, Flex Cables. Look for additional chassis codes to provide more detail. WBEM EventID: 1782. WBEM ProviderName: FPL_IndicationProvider. Failed to release the XBC semaphore after landmining a remote XBC port. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 1783. WBEM ProviderName: FPL_IndicationProvider. Failed to do a broadcast write to the XBC Remote Routing registers. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC. Look for additional chassis codes to describe the problem. WBEM EventID: 958. WBEM ProviderName: FPL_IndicationProvider. Failed to read a XBC Remote Routing register. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC. Look for additional chassis codes to describe the problem. WBEM EventID: 959. WBEM ProviderName: FPL_IndicationProvider. Failed to write a XBC Remote Routing register. Probable Cause: Fabric Access Failure, Recommended Action: Check XBC, Backplane, CC. Look for additional chassis codes to describe the problem. WBEM EventID: 960. WBEM ProviderName: FPL_IndicationProvider. Platform Events 65