HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 59
Error reading the local cell's XIN link state. Probable Cause: Hardware Access Error.
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Event ID Event Severity 8964 Error 8965 Error 8966 Error 8968 Warning 8969 Warning 8970 Warning 8971 Warning 8972 Warning 8973 Warning 8974 Warning 8975 Error 8976 Warning 8979 Warning 8981 Warning Event Description Couldn't write the XBC's forward progress register. Probable Cause: Fabric Access Error. Couldn't write this XBC. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 873. WBEM ProviderName: FPL_IndicationProvider. Couldn't access the XBC semaphore registers. Probable Cause: Fabric Access Error. Couldn't read or write this XBC. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 874. WBEM ProviderName: FPL_IndicationProvider. Couldn't determine the complex fabric topology. Probable Cause: Fabric Access Error. Couldn't write this XBC. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 875. WBEM ProviderName: FPL_IndicationProvider. Error checking a cell to cell link during traversability tests. Probable Cause: Probably an error reading the XIN. Look for additional descriptive chassis codes. Recommended Action: Contact HP Support personnel to check the CC. WBEM EventID: 876. WBEM ProviderName: FPL_IndicationProvider. An error occurred while traversing the cell to cell link. Probable Cause: Probably an error reading the XIN. Look for additional descriptive chassis codes. Recommended Action: Contact HP Support personnel to check the CC. WBEM EventID: 877. WBEM ProviderName: FPL_IndicationProvider. Error reading the local cell's XIN link state. Probable Cause: Hardware Access Error. Have your HP support representative check the Coherency Controller (CC). WBEM EventID: 878. WBEM ProviderName: FPL_IndicationProvider. Error reading the remote cell's XIN link state register. Probable Cause: Hardware Access Error. Have your HP support representative check the backplane and Coherency Controller (CC). WBEM EventID: 879. WBEM ProviderName: FPL_IndicationProvider. The XIN link is not connected to the target cell. Probable Cause: Ensure the cells are connected. Check historical chassis codes from most recent boot to see if the link had ever initialized. Have your HP support representative check the backplane and Coherency Controller (CC). WBEM EventID: 880. WBEM ProviderName: FPL_IndicationProvider. The XIN link is not connected to the target cell. Probable Cause: Ensure the cells are connected. Check historical chassis codes from most recent boot to see if the link had ever initialized. Have your HP support representative check the backplane and Coherency Controller (CC). WBEM EventID: 881. WBEM ProviderName: FPL_IndicationProvider. Error reading the XIN_LINK_STATE register while disabling the link. Probable Cause: Hardware Access Error. Recommended Action: Contact HP Support personnel to analyze the fabric, CC, Backplane. WBEM EventID: 882. WBEM ProviderName: FPL_IndicationProvider. Error reading the XIN_LINK_STATE register. Probable Cause: link init problem Recommended Action: Contact HP Support personnel to check the XBC, CC, backplane. WBEM EventID: 883. WBEM ProviderName: FPL_IndicationProvider. Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 884. WBEM ProviderName: FPL_IndicationProvider. The CPU is performance or functionally restricted. Probable Cause: A CPU is broken. Replace it. WBEM EventID: 885. WBEM ProviderName: FPL_IndicationProvider. The RTC was found to be invalid and has been cleared. Probable Cause: The RTC was invalid Recommended Action: No action is required. The problem has been corrected by SFW. WBEM EventID: 886. WBEM ProviderName: FPL_IndicationProvider. Platform Events 59