HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 60
Table #2, Event ID numbers 9, 000 through 12
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
Event ID Event Severity 8982 Warning 8983 Error 8984 Error Event Description Status indicates that the Late Self Tests did not actually run. Probable Cause: This could be caused by an incompatibity problem between PAL and the CPUs. Check that PAL supports all the CPUs installed on the system. WBEM EventID: 887. WBEM ProviderName: FPL_IndicationProvider. A fabric walk failed while updating the cell state. Probable Cause: Look for adjacent chassis codes to determine the cause of FabricWalk failure. Check the backplane and fabric connectivity. Contact the HP Support Personnel for further troubleshooting. WBEM EventID: 888. WBEM ProviderName: FPL_IndicationProvider. Could not reset the cell due to failure updating cell state. Probable Cause: Most likely a failure on the fabric or on the CC. Fabric failures should produce additional chassis codes. If no additional chassis codes indicate the cause of the failure, then contact the HP Support Personnel for further troubleshooting. WBEM EventID: 889. WBEM ProviderName: FPL_IndicationProvider. Table #2 - Event ID numbers 9,000 through 12,863 Event ID Event Severity 9000 Warning 9019 Error 9020 Error 9021 Error 9022 Warning 9038 Warning 9039 Warning 9040 Warning Event Description DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing DIMM Recommended Action: Replace the DIMM flagged by SFW. WBEM EventID: 890. WBEM ProviderName: FPL_IndicationProvider. System Clocks are not valid. Probable Cause: The Cell board has a problem. Either the Real Time Clock is not working properly or the system is not being clocked at the value it thinks it is. WBEM EventID: 891. WBEM ProviderName: FPL_IndicationProvider. Cell Online Addition failed due to fabric access error. Probable Cause: Fabric Access Failure, Recommended Action: Check CC to CC link. Look for additional failure chassis codes to provide more detail. WBEM EventID: 892. WBEM ProviderName: FPL_IndicationProvider. Fabric found a bad XBC port on a reboot. Attempting to route around it. Probable Cause: link errors. Recommended Action: Run DC Connectivity test. Check flex cables, XBCs, and CCs. WBEM EventID: 893. WBEM ProviderName: FPL_IndicationProvider. Could not access an internal firmware table while rerouting XBC port. Probable Cause: Firmware Error. Recommended Action: Capture chassis codes and contact HP Support. WBEM EventID: 894. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: Cell hardware problem like PDH memory itself, the coherency controller, the executing CPU or interaction between any of these cell components. Recommended Action: Contact HP Support to troubleshoot the cell and either fix it or replace it. WBEM EventID: 895. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction between any of these cell components. Recommended Action: Troubleshoot the cell and either fix it or replace it. WBEM EventID: 896. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction between any of these cell components. Recommended Action: Troubleshoot the cell and either fix it or replace it. WBEM EventID: 897. WBEM ProviderName: FPL_IndicationProvider. 60 WBEM Provider Event Tables