HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 70

The XBC CSR Low Severity error was not cleared. Probable Cause: This could

Page 70 highlights

Event ID Event Severity 9750 Warning 9751 Error 9753 Error 9754 Error 9755 Error 9768 Error 9769 Warning 9774 Warning 9775 Warning 9776 Warning Event Description Windows: Predictive Failure in Memory (Warning). Probable Cause: You will receive this message if the system is correcting a lot of ECC single bit errors. It may mean that the module is about to fail, or environmental conditions in the server are causing more errors than usual. This event message will be generated for one of the following conditions 1000 single-bit errors on the same address in a 48 hour time period. 50 single-bit errors on the same DIMM (not the same address) in a 24 hour time period. 100 single-bit errors on the same DIMM (not the same address) in a 1 week time period. Recommended Action: If you receive this message, contact your support provider to determine if a predictive repair should be made. WBEM EventID: 1820. WBEM ProviderName: FPL_IndicationProvider. Windows: Predictive Failure in Memory (Critical). Probable Cause: You will receive this message if the system is correcting a lot of ECC single bit errors. It may mean that the module is about to fail, or environmental conditions in the server are causing more errors than usual. This event message will be generated for one of the following conditions 1500 single-bit errors on the same address in a 72 hour time period. 120 single-bit errors on the same DIMM (not the same address) in a 24 hour time period. 130 single-bit errors on the same DIMM (not the same address) in a 1 week time period. Recommended Action: If you receive this message, contact your support provider to determine if a predictive repair should be made. WBEM EventID: 1821. WBEM ProviderName: FPL_IndicationProvider. A rope parity error occurred. Probable Cause: An unexpected but random error occurred. Reboot the system. There is a problem with the system bus. Contact your HP representative to check the system bus. WBEM EventID: 1822. WBEM ProviderName: FPL_IndicationProvider. PCI card inaccessible due to bus error. Probable Cause: An unexpected but random error occurred. Recommended Action: Reboot the system. WBEM EventID: 1823. WBEM ProviderName: FPL_IndicationProvider. PCI card inaccessible due to device error. Probable Cause: An unexpected but random error occurred. Reboot the system. There is a problem with the system bus. Contact your HP representative to check the system bus. Check the system forward progress log (available from the Management Processor) for additional information about this problem. WBEM EventID: 1824. WBEM ProviderName: FPL_IndicationProvider. error reading bmc first boot token. Probable Cause: FW tried to read the first boot token and received a failure. Recommended Action: AC power cycle the system . If this doesn't work, contact HP support. WBEM EventID: 1825. WBEM ProviderName: FPL_IndicationProvider. a rendezvousing cell is non PA architecture and thus incompatible. Probable Cause: other cell is an IA cell Recommended Action: replace IA cell with PA cell or reconfigure partition to exclude the IA cell. WBEM EventID: 1826. WBEM ProviderName: FPL_IndicationProvider. failed to write the XBC error log clear register. Probable Cause: Fabric Access Failure. Could not write to the XBC. This could indicate a hardware problem. Include the FABRIC_ERRORS_XBC_CLEAR_WR_ADDR event log and its data in any reports. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 1827. WBEM ProviderName: FPL_IndicationProvider. Error encountered while reading the XBC CSR Error Status Register. Probable Cause: Fabric Access Failure. Likely hardware problem. Look for additional chassis codes to further isolate the error. WBEM EventID: 1828. WBEM ProviderName: FPL_IndicationProvider. The XBC CSR Low Severity error was not cleared. Probable Cause: This could be caused by a fabric access error or persistent CSR Low Severity errors. Check Crossbar hardware, flex cables, backplane Recommended Action: Contact HP Support personnel to check the Crossbar hardware, flex cables, backplane. WBEM EventID: 1829. WBEM ProviderName: FPL_IndicationProvider. 70 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Windows: Predictive Failure in Memory (Warning). Probable Cause: You will receive
this message if the system is correcting a lot of ECC single bit errors. It may mean
that the module is about to fail, or environmental conditions in the server are causing
more errors than usual. This event message will be generated for one of the following
conditions 1000 single-bit errors on the same address in a 48 hour time period. 50
single-bit errors on the same DIMM (not the same address) in a 24 hour time period.
100 single-bit errors on the same DIMM (not the same address) in a 1 week time
period. Recommended Action: If you receive this message, contact your support
provider to determine if a predictive repair should be made. WBEM EventID: 1820.
WBEM ProviderName: FPL_IndicationProvider.
Warning
9750
Windows: Predictive Failure in Memory (Critical). Probable Cause: You will receive
this message if the system is correcting a lot of ECC single bit errors. It may mean
that the module is about to fail, or environmental conditions in the server are causing
more errors than usual. This event message will be generated for one of the following
conditions 1500 single-bit errors on the same address in a 72 hour time period. 120
single-bit errors on the same DIMM (not the same address) in a 24 hour time period.
130 single-bit errors on the same DIMM (not the same address) in a 1 week time
period. Recommended Action: If you receive this message, contact your support
provider to determine if a predictive repair should be made. WBEM EventID: 1821.
WBEM ProviderName: FPL_IndicationProvider.
Error
9751
A rope parity error occurred. Probable Cause: An unexpected but random error
occurred. Reboot the system. There is a problem with the system bus. Contact your
HP representative to check the system bus. WBEM EventID: 1822. WBEM
ProviderName: FPL_IndicationProvider.
Error
9753
PCI card inaccessible due to bus error. Probable Cause: An unexpected but random
error occurred. Recommended Action: Reboot the system. WBEM EventID: 1823.
WBEM ProviderName: FPL_IndicationProvider.
Error
9754
PCI card inaccessible due to device error. Probable Cause: An unexpected but random
error occurred. Reboot the system. There is a problem with the system bus. Contact
your HP representative to check the system bus. Check the system forward progress
log (available from the Management Processor) for additional information about this
problem. WBEM EventID: 1824. WBEM ProviderName: FPL_IndicationProvider.
Error
9755
error reading bmc first boot token. Probable Cause: FW tried to read the first boot
token and received a failure. Recommended Action: AC power cycle the system . If
this doesn't work, contact HP support. WBEM EventID: 1825. WBEM ProviderName:
FPL_IndicationProvider.
Error
9768
a rendezvousing cell is non PA architecture and thus incompatible. Probable Cause:
other cell is an IA cell Recommended Action: replace IA cell with PA cell or
reconfigure partition to exclude the IA cell. WBEM EventID: 1826. WBEM
ProviderName: FPL_IndicationProvider.
Warning
9769
failed to write the XBC error log clear register. Probable Cause: Fabric Access Failure.
Could not write to the XBC. This could indicate a hardware problem. Include the
FABRIC_ERRORS_XBC_CLEAR_WR_ADDR event log and its data in any reports.
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 1827. WBEM ProviderName: FPL_IndicationProvider.
Warning
9774
Error encountered while reading the XBC CSR Error Status Register. Probable Cause:
Fabric Access Failure. Likely hardware problem. Look for additional chassis codes
to further isolate the error. WBEM EventID: 1828. WBEM ProviderName:
FPL_IndicationProvider.
Warning
9775
The XBC CSR Low Severity error was not cleared. Probable Cause: This could be
caused by a fabric access error or persistent CSR Low Severity errors. Check Crossbar
hardware, flex cables, backplane Recommended Action: Contact HP Support
personnel to check the Crossbar hardware, flex cables, backplane. WBEM EventID:
1829. WBEM ProviderName: FPL_IndicationProvider.
Warning
9776
70
WBEM Provider Event Tables