HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 16
IPMI System Event Log SEL is full. Probable Cause: IPMI SEL full. Recommended
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Event ID Event Severity 5082 Warning 5083 Warning 5084 Error 5085 Error 5087 Warning 5091 Warning 5092 Warning 5098 Error 5100 Error 5101 Error 5102 Error 5103 Warning 5104 Error 5105 Error 5106 Error Event Description platform scratch RAM test failed. Probable Cause: Bad or corrupt Scratch RAM. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 248. WBEM ProviderName: FPL_IndicationProvider. CPU rendezvous failure. Probable Cause: Bad or slow CPU. Recommended Action: Replace CPU. WBEM EventID: 249. WBEM ProviderName: FPL_IndicationProvider. Error extracting sal_b from rom. Probable Cause: ROM Corrupt or unreadable. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 250. WBEM ProviderName: FPL_IndicationProvider. Scratch RAM bad. Probable Cause: Bad or corrupt Scratch RAM. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 251. WBEM ProviderName: FPL_IndicationProvider. IPMI System Event Log (SEL) is full. Probable Cause: IPMI SEL full. Recommended Action: Clear SEL through BMC or MP. WBEM EventID: 252. WBEM ProviderName: FPL_IndicationProvider. Slave wakeup before vector registered. Probable Cause: No wakeup vector registered for processor. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 253. WBEM ProviderName: FPL_IndicationProvider. CPU failed rendezvous handler. Probable Cause: SFW is unable to determine the FSB speed. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 254. WBEM ProviderName: FPL_IndicationProvider. Error building SMBIOS Tables. Probable Cause: SFW failed to build the SMBIOS tables. Recommended Action: If SMBIOS is preventing functionality, reboot. If problem persists contact your HP representative for support. WBEM EventID: 255. WBEM ProviderName: FPL_IndicationProvider. Trap nest limit exceeded. Probable Cause: The trap nesting limit has been exceeded. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 256. WBEM ProviderName: FPL_IndicationProvider. Trap not serviced. Probable Cause: A invalid trap has been requested or a trap has not been installed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 257. WBEM ProviderName: FPL_IndicationProvider. Trap taken. Probable Cause: A trap has been taken. Recommended action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 258. WBEM ProviderName: FPL_IndicationProvider. Uncleared interrupt. Probable Cause: At least one interrupt was not cleared. Recommended Action: No action is required. WBEM EventID: 259. WBEM ProviderName: FPL_IndicationProvider. Unexpected external interrupt. Probable Cause: An unexpected external interrupt has occurred. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 260. WBEM ProviderName: FPL_IndicationProvider. Interrupt before redirection table set up. Probable Cause: An interrupt has occurred before setting up the Interrupt Vector Table. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 261. WBEM ProviderName: FPL_IndicationProvider. CPU unexpected MCA. Probable Cause: Unexpected MCA. Recommended action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 262. WBEM ProviderName: FPL_IndicationProvider. 16 WBEM Provider Event Tables