HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 75
Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2926.
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Event ID Event Severity 10376 Warning 10377 Warning 10378 Warning 10379 Warning 10380 Warning 10381 Warning 10382 Warning 10384 Warning 10385 Warning 10386 Warning Event Description An invalid port number was given as an input to an Arches Fabric Traversability function. The port is expected to be an internal XBC num (8-15), but the actual port was not. Data field: (XBC number 32) | (port number 48). Probable Cause: Internal firmware error. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2919. WBEM ProviderName: FPL_IndicationProvider. Unable to read XBC port neighbor information. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2920. WBEM ProviderName: FPL_IndicationProvider. XBC port with an unexpected neighbor chip type. Data field: (expected chip type) | (actual chip type 16) | (xbcNum 32) |(portNum 48). Probable Cause: System firmware noticed a discrepancy from the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2921. WBEM ProviderName: FPL_IndicationProvider. An XBC port was found to have an unexpected neighbor ID. Data field: (expected NID) | (actual NID 16) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware found a discrepancy in the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2922. WBEM ProviderName: FPL_IndicationProvider. An XBC was found to have an unexpected neighbor port connection. Data field: (expected port) | (actual port 16) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware found a discrepancy in the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2923. WBEM ProviderName: FPL_IndicationProvider. The expected data was not found in the Arches Fabric expected edge list. Data field is unused. Probable Cause: Internal system firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2924. WBEM ProviderName: FPL_IndicationProvider. An XBC port has an unexpected neighbor chip type. Data field: neighbor type found. Probable Cause: System firmware found an unexpected chip in the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2925. WBEM ProviderName: FPL_IndicationProvider. A previously good XBC-XBC link was found to be down. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A link that was previously healthy was found to be down. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2926. WBEM ProviderName: FPL_IndicationProvider. An XBC port was found to have a Fatal Error during traversability test. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A link was found to have fatal errors, possible bad link/connection. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2927. WBEM ProviderName: FPL_IndicationProvider. Unable to read the local cell's LINK_SEL_FABRIC CSR. Data field: unused. Probable Cause: System firmware was unable to read a hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2928. WBEM ProviderName: FPL_IndicationProvider. Platform Events 75