HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 76
Error reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: xbcNum 32
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Event ID Event Severity 10387 Warning 10388 Warning 10389 Warning 10390 Warning 10391 Warning 10392 Warning 10393 Warning 10394 Warning 10395 Warning 10396 Warning 10397 Warning Event Description Unable to read the XBC route table. Data field: (route index) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2929. WBEM ProviderName: FPL_IndicationProvider. An XBC link was found to be not connected while testing CSR traffic traversability. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A previously healthy link was found to be down. Possible bad cable/connection. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2930. WBEM ProviderName: FPL_IndicationProvider. Error reading Skyline ALREC_ALB_ID CSR. Data field: (Skyline port) | (Cell number 56). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2931. WBEM ProviderName: FPL_IndicationProvider. A circular route was found while testing XBC CSR traffic traversability. Data field: (target XBC 32) | (cellNum 56). Probable Cause: Internal firmware error, fabric was routed incorrectly. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2932. WBEM ProviderName: FPL_IndicationProvider. Error reading ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2933. WBEM ProviderName: FPL_IndicationProvider. An XBC-XBC port had an invalid chip type connection. Data field: (expected chip type) | (actual chip type 32). Probable Cause: System firmware found a discrepancy in the system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2934. WBEM ProviderName: FPL_IndicationProvider. ArfIsXbcRouteTraversable was called on a back-to-back system which is an improper use of the function. Data field: unused. Probable Cause: Internal firmware error. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2935. WBEM ProviderName: FPL_IndicationProvider. In ArfIsXbcRouteTraversable, an XBC-XBC link was found to have fatal errors. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A previously healthy link was found to have fatal errors. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2936. WBEM ProviderName: FPL_IndicationProvider. Unable to read the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2937. WBEM ProviderName: FPL_IndicationProvider. Error reading an XBC ROUTE_TABLE CSR. Data field: route index | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2938. WBEM ProviderName: FPL_IndicationProvider. Error reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2939. WBEM ProviderName: FPL_IndicationProvider. 76 WBEM Provider Event Tables