HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 89

Failure reading IO backplane LPM. Probable Cause: IO backplane LPM is

Page 89 highlights

Event ID Event Severity 11485 Error 11486 Error 11487 Error 11488 Error 11489 Error 11495 Warning 11496 Warning 11515 Warning 11521 Warning 11529 Warning 11530 Warning Event Description Failure reading the Reset and Power Monitors (RPM) EEPROM. Probable Cause: device is not accessible over i2c. Recommended Action: check backplane power. WBEM EventID: 4921. WBEM ProviderName: FPL_IndicationProvider. Failure writing the Reset and Power Monitors (RPM) EEPROM. Probable Cause: device is not accessible over i2c. Recommended Action: check backplane power. WBEM EventID: 4922. WBEM ProviderName: FPL_IndicationProvider. Failure reading the Onboard System Programmers (OSP) EEPROM. Probable Cause: device is not accessible over i2c. Recommended Action: check backplane power. WBEM EventID: 4923. WBEM ProviderName: FPL_IndicationProvider. Failure writing the Onboard System Programmers (OSP) EEPROM. Probable Cause: device is not accessible over i2c. Recommended Action: check backplane power. WBEM EventID: 4924. WBEM ProviderName: FPL_IndicationProvider. SBS fault on startup. Probable Cause: SBS block for one of the MOAB's has reported an error on startup. Recommended Action: check backplane power. The physical location of the MOAB reporting the error is provided by data field. 0xFFFFXXFFFFFFFFFF where XX is: XX = 0x00 - Moab 0x00 XX = 0x01 - Moab 0x01 XX = 0x02 - Moab 0x02 XX = 0x10 - Moab 0x40 XX = 0x11 - Moab 0x41 XX = 0x12 Moab 0x42. WBEM EventID: 4925. WBEM ProviderName: FPL_IndicationProvider. Failure reading IO backplane LPM. Probable Cause: IO backplane LPM is not accessible over i2c. Recommended Action: Check power status of IO backplane. WBEM EventID: 4926. WBEM ProviderName: FPL_IndicationProvider. Failure writing IO backplane LPM. Probable Cause: IO Backplane LPM is not accessible over i2c. Recommended Action: Check power status of IO backplane. WBEM EventID: 4927. WBEM ProviderName: FPL_IndicationProvider. The system software violated one of the 'well-behavedness' rules of soft partitions and tried to call a firmware procedure within the firmware instance of a sibling. This is an access violation and firmware rejects the call. Probable Cause: System Software Defect - using the wrong entry address for the owner of the CPU. Recommended Action: Update the system software. WBEM EventID: 4928. WBEM ProviderName: FPL_IndicationProvider. AlbInitPrep was unable to read the ALREC_CONFIG CSR to determine whether the link is up or not. Data field: unused. Probable Cause: An error occurred while routing the fabric Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4929. WBEM ProviderName: FPL_IndicationProvider. The fPar whose ID is identified in the event detail is disabled from booting because it has no bootable, healthy CPU. It may not own any CPU or the CPUs it owns are Unhealthy (or deconfigured). Probable Cause: The fPar whose ID is identified in the event detail is disabled from booting because it has no bootable, healthy CPU. It may not own any CPU or the CPUs it owns are Unhealthy (or deconfigured) Recommended Action: Use the soft partitioning configuration tool released with the OS product to reconfigure the fPar and reboot the partition. A cold reset of the hard partition may be required. WBEM EventID: 4930. WBEM ProviderName: FPL_IndicationProvider. Non-critical event announces that an fPar is enabled to boot but has inadequate memory resources to instantiate the firmware for the fPar. The configuration is modified to disable but not delete this fPar. Probable Cause: The user has configured an fPar to be booted with inadequate memory resources to instantiate the firmware image for this fPar. The fPar is software deconfigured (disabled) from booting. Recommended Action: Reconfigure the fPar, giving it at least instance-size (an fPars EFI variable) amount of physically contiguous RAM. Then re-enable and reset the fPar. WBEM EventID: 4931. WBEM ProviderName: FPL_IndicationProvider. Platform Events 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Failure reading the Reset and Power Monitors (RPM) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4921. WBEM ProviderName: FPL_IndicationProvider.
Error
11485
Failure writing the Reset and Power Monitors (RPM) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4922. WBEM ProviderName: FPL_IndicationProvider.
Error
11486
Failure reading the Onboard System Programmers (OSP) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4923. WBEM ProviderName: FPL_IndicationProvider.
Error
11487
Failure writing the Onboard System Programmers (OSP) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4924. WBEM ProviderName: FPL_IndicationProvider.
Error
11488
SBS fault on startup. Probable Cause: SBS block for one of the MOAB's has reported
an error on startup. Recommended Action: check backplane power. The physical
location of the MOAB reporting the error is provided by data field.
0xFFFFXXFFFFFFFFFF where XX is: XX = 0x00 - Moab 0x00 XX = 0x01 - Moab 0x01
XX = 0x02 - Moab 0x02 XX = 0x10 - Moab 0x40 XX = 0x11 - Moab 0x41 XX = 0x12 -
Moab 0x42. WBEM EventID: 4925. WBEM ProviderName: FPL_IndicationProvider.
Error
11489
Failure reading IO backplane LPM. Probable Cause: IO backplane LPM is not
accessible over i2c. Recommended Action: Check power status of IO backplane.
WBEM EventID: 4926. WBEM ProviderName: FPL_IndicationProvider.
Warning
11495
Failure writing IO backplane LPM. Probable Cause: IO Backplane LPM is not
accessible over i2c. Recommended Action: Check power status of IO backplane.
WBEM EventID: 4927. WBEM ProviderName: FPL_IndicationProvider.
Warning
11496
The system software violated one of the 'well-behavedness' rules of soft partitions
and tried to call a firmware procedure within the firmware instance of a sibling. This
is an access violation and firmware rejects the call. Probable Cause: System Software
Defect - using the wrong entry address for the owner of the CPU. Recommended
Action: Update the system software. WBEM EventID: 4928. WBEM ProviderName:
FPL_IndicationProvider.
Warning
11515
AlbInitPrep was unable to read the ALREC_CONFIG CSR to determine whether the
link is up or not. Data field: unused. Probable Cause: An error occurred while routing
the fabric Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 4929.
WBEM ProviderName: FPL_IndicationProvider.
Warning
11521
The fPar whose ID is identified in the event detail is disabled from booting because
it has no bootable, healthy CPU. It may not own any CPU or the CPUs it owns are
Unhealthy (or deconfigured). Probable Cause: The fPar whose ID is identified in the
event detail is disabled from booting because it has no bootable, healthy CPU. It may
not own any CPU or the CPUs it owns are Unhealthy (or deconfigured) Recommended
Action: Use the soft partitioning configuration tool released with the OS product to
reconfigure the fPar and reboot the partition. A cold reset of the hard partition may
be required. WBEM EventID: 4930. WBEM ProviderName: FPL_IndicationProvider.
Warning
11529
Non-critical event announces that an fPar is enabled to boot but has inadequate
memory resources to instantiate the firmware for the fPar. The configuration is
modified to disable but not delete this fPar. Probable Cause: The user has configured
an fPar to be booted with inadequate memory resources to instantiate the firmware
image for this fPar. The fPar is software deconfigured (disabled) from booting.
Recommended Action: Reconfigure the fPar, giving it at least instance-size (an fPars
EFI variable) amount of physically contiguous RAM. Then re-enable and reset the
fPar. WBEM EventID: 4931. WBEM ProviderName: FPL_IndicationProvider.
Warning
11530
Platform Events
89