HP SAS Events, HP SCSI Events
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
HP SAS Events Source in Windows Event Log: HP SAS Event ID Event Severity Event Description 1 Information A SAS/SATA HBA status has changed from non-OK to OK. 2 Error A SAS/SATA HBA status has changed to Error. 101 Information A logical drive status has changed from non-OK to OK. 102 Error A logical drive status has changed to Error. 103 Warning A logical drive is in a degraded state. Device is still servicing I/O, but redundancy may be degraded or lost. 201 Information A physical drive status has changed from non-OK to OK. 202 Error A physical drive status has changed to Error. 203 Information A physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the RAID set. 204 Warning A physical drive status has changed to Predictive Failure. 301 Warning A Storage Enclosure Power Subsystem status has changed to non-redundant. 302 Information A Storage Enclosure Power Supply has changed to Fully Redundant. 303 Warning A Storage Enclosure Power Supply status has changed to Degraded Redundancy. 304 Information A Storage Enclosure Fan status has changed from a non-OK state to OK. 305 Warning A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans. 306 Error A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. 307 Information A Storage Enclosure Temperature sensor status changed from non-OK to OK. 308 Warning A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. 309 Error A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. HP SCSI Events Source in Windows Event Log: HP SCSI Event ID Event Severity Event Description 1 Information A SCSI device status has changed to Unknown. 2 Information This SCSI HBA status has changed from non-OK to OK. 3 Error A SCSI HBA status has changed to Error. 4 Information A SCSI physical drive status has changed from non-OK to OK. 5 Error A SCSI physical drive has a status of Error. HP SAS Events 107