HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 98
to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane, IO
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Event ID Event Severity 12119 Warning 12120 Warning 12121 Warning 12127 Warning 12128 Warning 12129 Warning 12130 Warning 12131 Warning 12132 Error Event Description One or more of the cells are not configured for Cell-Local Memory (CLM) mode. Probable Cause: The initial partition configuration may have not specified 100% Cell-Local Memory or may have been reconfigured incorrectly. Recommended Action: Reconfigure the partition or reset the CLM setting on one or more cells in your partition using the Partition Manager or ParCLI tools. WBEM EventID: 5259. WBEM ProviderName: FPL_IndicationProvider. Double DRAM chip sparing events have been invoked. Probable Cause: System firmware has detected and corrected memory errors. Double DRAM chip sparing events have been invoked to help mitigate this condition. On the next reboot, system firmware will test the specified memory components, and may take them offline if the errors persist. Recommended Action: Contact your HP support representative to check the specified memory. WBEM EventID: 5260. WBEM ProviderName: FPL_IndicationProvider. A platform error was detected by the firmware/hardware, and corrected by using a spare channel. Probable Cause: Hardware has detected many link retries on one of its channels and has switched to a spare one. Recommended Action: Monitor the situation and contact your HP support representative to check the affected hardware. WBEM EventID: 5261. WBEM ProviderName: FPL_IndicationProvider. A platform error was detected by the firmware/hardware, and corrected by using a spare channel. Probable Cause: The error occurred between the crossbar chips on the backplane(s). Recommended Action: Contact your support representative to have the backplane and / or connections between backplanes checked. WBEM EventID: 5263. WBEM ProviderName: FPL_IndicationProvider. A platform error was detected by the firmware/hardware, and corrected by using a spare channel. Probable Cause: The error occurred between the cell controller and the IO controller. Recommended Action: Contact your support representative to have the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane, cell, or system backplane. WBEM EventID: 5264. WBEM ProviderName: FPL_IndicationProvider. Multiple platform errors were detected and corrected by the firmware/hardware. Probable Cause: The errors occurred between the cell controller and the backplane. Recommended Action: Contact your support representative to have the Cell Controller to backplane Interface checked. WBEM EventID: 5265. WBEM ProviderName: FPL_IndicationProvider. Multiple platform errors were detected and corrected by the firmware/hardware. Probable Cause: The errors occurred between the crossbar chips on the backplane(s). Recommended Action: Contact your support representative to have the backplane and / or connections between backplanes checked. WBEM EventID: 5266. WBEM ProviderName: FPL_IndicationProvider. Multiple platform errors were detected and corrected by the firmware/hardware. Probable Cause: The errors occurred between the cell controller and the IO controller. Recommended Action: Contact your support representative to have the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane, cell, or system backplane. WBEM EventID: 5267. WBEM ProviderName: FPL_IndicationProvider. The server ID does not match the cabinet type. Probable Cause: The cabinet type is not in agreement with the server identification information. The server identification information is viewable using the ID command from the MP's command menu. The cabinet type is displayed in the top line of the cabinet status shown when the PS command from the MP's command menu is used to target a compute cabinet. Recommended Action: Contact your support representative to have the server identification information and cabinet type checked. WBEM EventID: 5269. WBEM ProviderName: FPL_IndicationProvider. 98 WBEM Provider Event Tables