HP 6125G HP 6125G & 6125G/XG Blade Switches Network Management and Mon - Page 102

rmon alarm

Page 102 highlights

Field Description Incoming-packet statistics by packet length for the statistical period: • 64-Number of 64-byte packets. The value is stored in the MIB node etherStatsPkts64Octets. • 65-127-Number of 65- to 127-byte packets. The value is stored in the MIB node etherStatsPkts65to127Octets. • 128-255-Number of 128- to 255-byte packets. to the value is Packets received according to length: stored in the MIB node etherStatsPkts128to255Octets. • 256-511-Number of 256- to 511-byte packets. The value is stored in the MIB node etherStatsPkts256to511Octets. • 512-1023-Number of 512- to 1023-byte packets. The value is stored in the MIB node etherStatsPkts512to1023Octets. • 1024-1518-Number of 1024- to 1518-byte packets. The value is stored in the MIB node etherStatsPkts1024to1518Octets. rmon alarm Syntax rmon alarm entry-number alarm-variable sampling-interval { absolute | delta } rising-threshold threshold-value1 event-entry1 falling-threshold threshold-value2 event-entry2 [ owner text ] View undo rmon alarm entry-number System view Default level 2: System level Parameters entry-number: Specifies the alarm entry index, which ranges from 1 to 65535. alarm-variable: Specifies the alarm variable, a string of 1 to 256 characters. It can be in dotted object identifier (OID) format (in the format of entry.integer.instance or leaf node name.instance, for example, 1.3.6.1.2.1.2.1.10.1), or a node name like ifInOctets.1. Only variables that can be parsed into INTEGER (INTEGER, Counter, Gauge, or Time Ticks) in the ASN.1 can be used for the alarm-variable argument, such as the instance of the leaf node (like etherStatsOctets, etherStatsPkts, etherStatsBroadcastPkts, and so on) of the etherStatsEntry entry, the instance of the leaf node (like ifInOctets, ifInUcastPkts, ifInNUcastPkts, and so on) of the ifEntry entry. sampling-interval: Specifies the sampling interval, which ranges from 5 to 65535 seconds. absolute: Sets the sampling type to absolute. In other words, the system obtains the value of the variable when the sampling time is reached. delta: Sets the sampling type to delta. In other words, the system obtains the variation value of the variable during the sampling interval when the sampling time is reached. rising-threshold threshold-value1 event-entry1: Sets the rising threshold, where the threshold-value1 argument represents the rising threshold, in the range -2147483648 to +2147483647, and the event-entry1 argument represents the index of the event triggered when the rising threshold is reached. event-entry1 ranges from 0 to 65535. If 0 is specified, the alarm does not trigger any event. 96

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

96
Field
Description
Packets received according to length:
Incoming-packet statistics by packet length for the statistical period:
64
—Number of 64-byte packets. The value is stored in the MIB
node etherStatsPkts64Octets.
65-127
—Number of 65- to 127-byte packets. The value is stored in
the MIB node etherStatsPkts65to127Octets.
128-255
—Number of 128- to 255-byte packets. to the value is
stored in the MIB node etherStatsPkts128to255Octets.
256-511
—Number of 256- to 511-byte packets. The value is stored
in the MIB node etherStatsPkts256to511Octets.
512-1023
—Number of 512- to 1023-byte packets. The value is
stored in the MIB node etherStatsPkts512to1023Octets.
1024-1518
—Number of 1024- to 1518-byte packets. The value is
stored in the MIB node etherStatsPkts1024to1518Octets.
rmon alarm
Syntax
rmon alarm
entry
-
number alarm
-
variable sampling
-
interval
{
absolute
|
delta
}
rising-threshold
threshold
-
value1
event
-
entry1
falling-threshold
threshold
-
value2
event
-
entry2
[
owner
text
]
undo rmon alarm
entry
-
number
View
System view
Default level
2: System level
Parameters
entry
-
number
: Specifies the alarm entry index, which ranges from 1 to 65535.
alarm
-
variable
: Specifies the alarm variable, a string of 1 to 256 characters. It can be in dotted object
identifier (OID) format (in the format of
entry.integer.instance
or
leaf node name
.
instance
, for example,
1.3.6.1.2.1.2.1.10.1), or a node name like ifInOctets.1. Only variables that can be parsed into INTEGER
(INTEGER, Counter, Gauge, or Time Ticks) in the ASN.1 can be used for the
alarm
-
variable
argument,
such as the instance of the leaf node (like etherStatsOctets, etherStatsPkts, etherStatsBroadcastPkts, and
so on) of the etherStatsEntry entry, the instance of the leaf node (like ifInOctets, ifInUcastPkts,
ifInNUcastPkts, and so on) of the ifEntry entry.
sampling
-
interval
: Specifies the sampling interval, which ranges from 5 to 65535 seconds.
absolute
: Sets the sampling type to
absolute
. In other words, the system obtains the value of the variable
when the sampling time is reached.
delta
: Sets the sampling type to
delta
. In other words, the system obtains the variation value of the
variable during the sampling interval when the sampling time is reached.
rising-threshold
threshold
-
value1 event
-
entry1
: Sets the rising threshold, where the
threshold-value1
argument represents the rising threshold, in the range –2147483648 to +2147483647, and the
event-entry1
argument represents the index of the event triggered when the rising threshold is reached.
event-entry1
ranges from 0 to 65535. If 0 is specified, the alarm does not trigger any event.