frequency, history-record enable
View all HP 6125G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
frequency Syntax frequency interval View undo frequency Any NQA operation view Default level 2: System level Parameters interval: Specifies the interval in milliseconds between two consecutive tests, in the range of 0 to 604800000. The value 0 sets the test group to perform only one test, and not to collect any statistics. Description Use frequency to configure the interval between two consecutive tests for a test group. When a test group starts, it performs tests one by one at the specified interval. However, if a test is not completed when the interval is reached, no new test starts. Use undo frequency to restore the default. By default, the interval between two consecutive voice tests is 60000 milliseconds, and the interval between two consecutive tests of other types is 0 milliseconds. Examples # Configure the ICMP echo test group starts tests one by one at an interval of 1000 milliseconds. system-view [Sysname] nqa entry admin test [Sysname-nqa-admin-test] type icmp-echo [Sysname-nqa-admin-test-icmp-echo] frequency 1000 history-record enable Syntax history-record enable View undo history-record enable Any NQA operation view Default level 2: System level Parameters None Description Use history-record enable to enable the saving of history records of an NQA test group. Use undo history-record enable to disable the history records saving function. 131