HP 6125G HP 6125G & 6125G/XG Blade Switches Network Management and Mon - Page 55
info-center trapbuffer, reset logbuffer
View all HP 6125G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Examples # Configure the time stamp format for system information sent to the log host as no-year-date. system-view [Sysname] info-center timestamp loghost no-year-date info-center trapbuffer Syntax info-center trapbuffer [ channel { channel-number | channel-name } | size buffersize ] * View undo info-center trapbuffer [ channel | size ] System view Default level 2: System level Parameters size buffersize: Specifies the maximum number of trap messages allowed in the trap buffer, in the range of 0 to 1,024. The default value is 256. channel-number: Specifies a channel by its number in the range of 0 to 9. channel-name: Specifies a channel by its name, a default name or a self-defined name. For how to configure a channel name, see info-center channel name. Description Use info-center trapbuffer to enable information output to the trap buffer and set the corresponding parameters. Use undo info-center trapbuffer to disable information output to the trap buffer. By default, the system outputs information to the trap buffer through channel 3 (trapbuffer), and the maximum buffer size is 256. The info-center trapbuffer command takes effect only after the information center has been enabled with the info-center enable command. Examples # Output system information to the trap buffer through the default channel, and set the trap buffer size to 30. system-view [Sysname] info-center trapbuffer size 30 reset logbuffer Syntax reset logbuffer View User view 49