HP 6125G HP 6125G & 6125G/XG Blade Switches Network Management and Mon - Page 21

Maximum error of the system clock relative to the reference clock., root delay

Page 21 highlights

Field local mode local poll peer mode peer poll offset delay disper root delay root disper reach sync dist sync state precision version Description Operation mode of the local device: • unspec-The mode is unspecified. • active-Active mode. • passive-Passive mode. • client-Client mode. • server-Server mode. • bdcast-Broadcast server mode. • control-Control query mode. • private-Private message mode. Poll interval of the local device, in seconds. The value displayed is a power of 2. For example, if the displayed value is 6, the poll interval of the local device is 26, or 64 seconds. Operation mode of the peer device: • unspec-The mode is unspecified. • active-Active mode. • passive-Passive mode. • client-Client mode. • server-Server mode. • bdcast-Broadcast server mode. • control-Control query mode. • private-Private message mode. Poll interval of the peer device, in seconds. The value displayed is a power of 2. For example, if the displayed value is 6, the poll interval of the local device is 26, or 64 seconds. Offset of the system clock relative to the reference clock, in milliseconds. Roundtrip delay from the local device to the clock source, in milliseconds. Maximum error of the system clock relative to the reference clock. Roundtrip delay from the local device to the primary reference source, in milliseconds. Maximum error of the system clock relative to the primary reference clock, in milliseconds. Reachability count of the clock source. A value of 0 indicates that the clock source is unreachable. Synchronization distance relative to the upper-level clock, in seconds, and calculated from dispersion and roundtrip delay values. State of the state machine. Displayed value is an integer that ranges from 0 to 5. Precision of the system clock. NTP version. Displayed value is an integer that ranges from 1 to 4. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

15
Field
Description
local mode
Operation mode of the local device:
unspec
—The mode is unspecified.
active
—Active mode.
passive
—Passive mode.
client
—Client mode.
server
—Server mode.
bdcast
—Broadcast server mode.
control
—Control query mode.
private
—Private message mode.
local poll
Poll interval of the local device, in seconds. The value displayed is a
power of 2. For example, if the displayed value is 6, the poll interval
of the local device is 26, or 64 seconds.
peer mode
Operation mode of the peer device:
unspec
—The mode is unspecified.
active
—Active mode.
passive
—Passive mode.
client
—Client mode.
server
—Server mode.
bdcast
—Broadcast server mode.
control
—Control query mode.
private
—Private message mode.
peer poll
Poll interval of the peer device, in seconds. The value displayed is a
power of 2. For example, if the displayed value is 6, the poll interval
of the local device is 26, or 64 seconds.
offset
Offset of the system clock relative to the reference clock, in
milliseconds.
delay
Roundtrip delay from the local device to the clock source, in
milliseconds.
disper
Maximum error of the system clock relative to the reference clock.
root delay
Roundtrip delay from the local device to the primary reference
source, in milliseconds.
root disper
Maximum error of the system clock relative to the primary reference
clock, in milliseconds.
reach
Reachability count of the clock source. A value of 0 indicates that
the clock source is unreachable.
sync dist
Synchronization distance relative to the upper-level clock, in
seconds, and calculated from dispersion and roundtrip delay
values.
sync state
State of the state machine.
Displayed value is an integer that ranges from 0 to 5.
precision
Precision of the system clock.
version
NTP version.
Displayed value is an integer that ranges from 1 to 4.