HP 6125G HP 6125G & 6125G/XG Blade Switches Network Management and Mon - Page 172
nqa server tcp-connect tos, nqa server udp-echo
View all HP 6125G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 172 highlights
The IP address and port number must be consistent with those on the NQA client and must be different from those for an existing listening service. The IP address must be that of an interface on the NQA server. Otherwise, the configuration will be invalid. Related commands: nqa server enable and display nqa server status. Examples # Create a TCP listening service by using the IP address 169.254.10.2 and port 9000. system-view [Sysname] nqa server tcp-connect 169.254.10.2 9000 nqa server tcp-connect tos Syntax nqa server tcp-connect tos tos undo nqa server tcp-connect tos View System view Default level 2: System level Parameters tos: Specifies the value of the ToS field, in the range of 0 to 255. Description Use nqa server tcp-connect tos to configure the ToS value in the packets sent by TCP listening service on the NQA server. Use undo nqa server tcp-connect tos to restore the default value. By default, the ToS value is 0. Examples # Set the ToS value to 30 in the packets sent by the TCP listening service on the NQA server, system-view [Sysname] nqa server tcp-connect tos 30 nqa server udp-echo Syntax nqa server udp-echo ip-address port-number View undo nqa server udp-echo ip-address port-number System view Default level 2: System level 166