HP 6125G HP 6125G & 6125G/XG Blade Switches Network Management and Mon - Page 152
reaction checked-element mos
View all HP 6125G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
entry is set to over-threshold. Otherwise, the state is set to below-threshold. Once state of the reaction entry changes, a trap message is generated and sent to the network management server. system-view [Sysname] nqa entry admin test [Sysname-nqa-admin-test] type udp-jitter [Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element jitter-ds threshold-type average threshold-value 50 5 action-type trap-only # Create reaction entry 2 for monitoring the destination-to-source delay jitter of UDP jitter probe packets. Set the upper threshold to 50 milliseconds, and the lower threshold to 5 milliseconds. Before the NQA test group starts, the initial state of the reaction entry is invalid. After each test, the destination-to-source delay jitter is checked against the threshold range. If the total number of threshold violations exceeds 100 (included), the state of the entry is set to over-threshold. Otherwise, the state of the entry is set to below-threshold. Once the state of the reaction entry changes, a trap message is generated and sent to the network management server. system-view [Sysname] nqa entry admin test [Sysname-nqa-admin-test] type udp-jitter [Sysname-nqa-admin-test-udp-jitter] reaction 2 checked-element jitter-ds threshold-type accumulate 100 threshold-value 50 5 action-type trap-only reaction checked-element mos Syntax reaction item-number checked-element mos threshold-value upper-threshold lower-threshold [ action-type { none | trap-only } ] undo reaction item-number View Voice operation view Default level 2: System level Parameters item-number: Specifies a reaction entry ID, in the range of 1 to 10. threshold-value: Specifies threshold values. upper-threshold: Specifies an upper threshold, in the range of 1 to 500. lower-threshold: Specifies a lower threshold, in the range of 1 to 500. It must not be greater than the upper threshold. action-type: Specifies what action to be triggered to react to certain measurement conditions and it defaults to none. none: Specifies to only record events for terminal display, and not to send any trap messages. trap-only: Specifies to record events and send SNMP trap messages. Description Use reaction checked-element mos to configure a reaction entry for monitoring the MOS value in each voice test of an NQA operation. You cannot edit a reaction entry. To change the attributes in a reaction entry, use undo reaction to delete this entire entry and start over. 146