HP StorageWorks 2/16V Brocade Fabric OS Command Reference Manual (53-1000240-0 - Page 675
spinSilk, Examples, Diagnostics, To perform a functional test on selected ports
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 675 highlights
Note: Enter commands in lowercase only; mixed case is for readability. spinSilk 2 Examples To perform a functional test on selected ports: switch:admin> spinsilk -ports 1/0 - 1/2 Running Spin Silk One moment please ...Ports Segmented (0) switchName: switch switchType: 10.1 switchState: Offline switchRole: Disabled switchDomain: 1 (unconfirmed) switchId: fffc01 switchWwn: 10:00:00:60:69:80:03:0c switchBeacon: OFF blade1: Beacon: OFF blade2: Beacon: OFF blade3: Beacon: OFF blade4: Beacon: OFF Area Slot Port Gbic Speed State 0 1 0 id 2G Online Testing 1 1 1 id 2G Online Testing 2 1 2 id 2G Online Testing (output truncated) Diagnostics Following are the possible error messages if failures are detected: DATA EPI1_STATUS_ERR ERR_STAT ERR_STATS ERR_STATS_2LONG ERR_STATS_BADEOF ERR_STATS_BADOS ERR_STATS_C3DISC ERR_STATS_CRC ERR_STATS_ENCIN ERR_STATS_ENCOUT ERR_STATS_TRUNC ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FDET_PERR FINISH_MSG_ERR FTPRT_STATUS_ERR INIT LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERRBAR> NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-641