Yamaha 02R96 Owner's Manual - Page 297
Parameter Address
View all Yamaha 02R96 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 297 highlights
284 Appendix C: MIDI 12.3.4 Parameter request basic format (Universal format) STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0011nnnn 3n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 01111111 7F Universal ADDRESS 0ttttttt tt Data type 0eeeeeee ee Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) 0ppppppp pp Parameter No. 0ccccccc cc Channel No. EOX 11110111 F7 End of exclusive 12.3.5 Parameter Address Consult your dealer for parameter address details. 12.3.6 Parameter change (Edit buffer) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the specified parameter will be controlled. Transmission If [Parameter change TX] is ON and a parameter not specified in the [Control assign table] is modified, this message will be transmitted with the device number specified by the [Tx CH]. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 01111111 7F Universal ADDRESS 00000001 01 Edit Buffer 0eeeeeee ee Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) 0ppppppp pp Parameter No. 0ccccccc cc Channel No. DATA 0ddddddd dd Data : : EOX 11110111 F7 End of exclusive 12.3.7 Parameter request (Edit buffer) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be transmitted as a Parameter Change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0011nnnn 3n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 01111111 7F Universal ADDRESS 00000001 01 Edit Buffer 0eeeeeee ee Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) 0ppppppp pp Parameter No. 0ccccccc cc Channel No. EOX 11110111 F7 End of exclusive 12.3.8 Parameter change (Patch data) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the specified parameter will be controlled. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID MODEL ID ADDRESS DATA EOX 00111110 3E MODEL ID (digital mixer) 00001011 0B 02R96 00000010 02 Patch data 0eeeeeee ee Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) 0ppppppp pp Parameter No. 0ccccccc cc Channel No. 0ddddddd dd Data : : 11110111 F7 End of exclusive 12.3.9 Parameter request (Patch data) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be transmitted as a Parameter Change. STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS EOX 11110000 F0 01000011 43 0011nnnn 3n 00111110 3E 00001011 0B 00000010 02 0eeeeeee ee 0ppppppp pp 0ccccccc cc 11110111 F7 System exclusive message Manufacture's ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) 02R96 Patch data Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) Parameter No. Channel No. End of exclusive 12.3.10 Parameter change (Setup memory) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be controlled. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00001011 0B 02R96 ADDRESS 00000011 03 Setup memory 0eeeeeee ee Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) 0ppppppp pp Parameter No. 0ccccccc cc Channel No. DATA 0ddddddd dd Data : : EOX 11110111 F7 End of exclusive 12.3.11 Parameter request (Setup memory) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be transmitted as a Parameter Change. STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS EOX 11110000 F0 01000011 43 0011nnnn 3n 00111110 3E 00001011 0B 00000011 03 0eeeeeee ee 0ppppppp pp 0ccccccc cc 11110111 F7 System exclusive message Manufacture's ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) 02R96 Setup memory Element No. (If 'ee' is 0, 'ee' is expanded to two bytes) Parameter No. Channel No. End of exclusive 02R96-Owner's Manual