Dell PowerConnect B - MLXe 16 Hardware Installation Guide - Page 115
TABLE 19, Managing the device, The output displays the following information.
View all Dell PowerConnect B - MLXe 16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
Managing the device 5 right fan tray (fan 1): Status = OK, Speed = MED-HI (90%) right fan tray (fan 2): Status = OK, Speed = MED-HI (90%) --- TEMPERATURE READINGS --Active Mgmt Module: 36.500C 49.625C Standby Mgmt Module: 36.250C 51.0C SNM1: 37.0C SNM2: 38.0C SNM3: not present LP1 Sensor1: 41.5C LP1 Sensor2: 50.625C LP4 Sensor1: 39.0C LP4 Sensor2: 49.250C LP4 Sensor3: UNUSED LP4 Sensor4: 38.5C LP4 Sensor5: 47.750C LP4 Sensor6: UNUSED Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds The output displays the following information. TABLE 19 show chassis command output This field... Displays... Powers Power , Power The Power is the power supply number as positioned in the device. The number of power supplies are as follows: 4-slot devices: 1 - 3 8-slot devices: 1 - 4 16-slot devices: 1 - 8 The is the part number of the power supply purchased. This applies to AC power supplies. Indicates whether an AC power supply is installed in the specified power supply slot and the status of the power supply, which can be one of the following: • Installed (Shutdown)-The power supply has shut down. A power supply will shut down due to flapping, or if a shut down is enabled manually using the power-off power-supply command. Refer to "Enabling a power supply shutdown" on page 165. • Installed (OK) - The power supply is functioning properly and supplying power to the device and installed modules. • Failed - The power supply is not functioning and is not supplying power to the device and installed modules. • not present - There is no power supply installed in the slot. • Installed (Failed or Disconnected) - The power supply is not functioning, or the power supply is not connected to the device and installed modules. Total power budget for device The sum of all power (in watts), used by all power supplies currently functioning in the device. Total power used by system core The total power used by the management modules, switch fabric modules, and fans. Each component consumes different amounts of power. Total power used by LPs The total power used by the interface modules. Each module type consumes different amounts of power. Total power available The total power budget for the device minus the total power used by the system core and the installed interface modules. Slot Power-On Priority The configured power-on priority of each interface module. PowerConnect B-MLXe Hardware Installation Guide 103 53-1002111-01