Dell PowerConnect B - MLXe 16 Hardware Installation Guide - Page 157

Configurations conditions specific to NI-MLX-1Gx48-T modules

Page 157 highlights

Configurations conditions specific to NI-MLX-1Gx48-T modules 6 LP Slot 4 uptime is 58 seconds SL 6: NI-MLX-10Gx4 4-port 10GbE Module (Serial #: SA12090950, Part #: 35600-202D) Boot: Version 5.1.0T175 Copyright (c) 1996-2009 Brocade Communications Systems, Inc. Compiled on Aug 11 2010 at 14:07:20 labeled as xmlprm05100 (492544 bytes) from boot flash Monitor: Version 5.1.0T175 Copyright(c)1996-2009 Brocade Communications Systems, Inc. Compiled on Aug 11 2010 at 14:07:42 labeled as xmlb05100 (493244 bytes) from code flash IronWare: Version 5.1.0T177 Copyright(c)1996-2009 Brocade Communications Systems, Inc. Compiled on Sep 16 2010 at 17:55:24 labeled as xmlp05100 (4950936 bytes) from Primary FPGA versions: Valid PBIF Version = 3.22, Build Time = 2/5/2010 14:43:00 Valid XPP Version = 6.04, Build Time = 2/3/2010 14:39:00 Valid XGMAC Version = 0.13, Build Time = 2/3/2010 14:42:00 X10G2MAC 0 X10G2MAC 1 666 MHz MPC 8541 (version 8020/0020) 333 MHz bus 512 KB Boot Flash (AM29LV040B), 16 MB Code Flash (MT28F640J3) 512 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM PPCR0: 768K entries CAM, 8192K PRAM, 2048K AGE RAM PPCR1: 768K entries CAM, 8192K PRAM, 2048K AGE RAM LP Slot 6 uptime is 59 seconds All show version done Configurations conditions specific to NI-MLX-1Gx48-T modules ifIndex allocation The SNMP Management Information Base (MIB) uses the Interface Index (ifIndex) to assign a unique value to each port on a module or slot. • If you will be installing the NI-MLX-1Gx48-T module on your device, you must configure the maximum ifIndex per module to 64. You must change the ifIndex allocation before installing the NI-MLX-1Gx48-T module; otherwise, the module remains in the Offline state. • If you have a new device (no previous software installed), and you will be installing an NI-MLX-1Gx48-T module, you must configure the maximum ifIndex per module to 64; otherwise, the module remains in the Offline state. • If you have a new device (no previous software installed), and will not be installing an NI-MLX-1Gx48-T module, it is recommended that you configure the maximum ifIndex per module to 64 to avoid future ifIndex problems if you decide to install an NI-MLX-1Gx48-T module in the future. Port MAC address change The MAC address assigned to each port may change to accommodate a greater number of ports per module. The MAC address ports allocated for each module has increased from 20 to 48. PowerConnect B-MLXe Hardware Installation Guide 145 53-1002111-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

PowerConnect B-MLXe Hardware Installation Guide
145
53-1002111-01
Configurations conditions specific to NI-MLX-1Gx48-T modules
6
LP Slot 4 uptime is 58 seconds
==========================================================================
SL 6: NI-MLX-10Gx4 4-port 10GbE Module (Serial #: SA12090950, Part #: 35600-202D)
Boot: Version 5.1.0T175 Copyright (c) 1996-2009 Brocade Communications Systems,
Inc.
Compiled on Aug 11 2010 at 14:07:20 labeled as xmlprm05100
(492544 bytes) from boot flash
Monitor: Version 5.1.0T175 Copyright(c)1996-2009 Brocade Communications Systems,
Inc.
Compiled on Aug 11 2010 at 14:07:42 labeled as xmlb05100
(493244 bytes) from code flash
IronWare: Version 5.1.0T177 Copyright(c)1996-2009 Brocade Communications Systems,
Inc.
Compiled on Sep 16 2010 at 17:55:24 labeled as xmlp05100
(4950936 bytes) from Primary
FPGA versions:
Valid PBIF Version = 3.22, Build Time = 2/5/2010 14:43:00
Valid XPP Version = 6.04, Build Time = 2/3/2010 14:39:00
Valid XGMAC Version = 0.13, Build Time = 2/3/2010 14:42:00
X10G2MAC 0
X10G2MAC 1
666 MHz MPC 8541 (version 8020/0020) 333 MHz bus
512 KB Boot Flash (AM29LV040B), 16 MB Code Flash (MT28F640J3)
512 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM
PPCR0: 768K entries CAM, 8192K PRAM, 2048K AGE RAM
PPCR1: 768K entries CAM, 8192K PRAM, 2048K AGE RAM
LP Slot 6 uptime is 59 seconds
==========================================================================
All show version done
Configurations conditions specific to NI-MLX-1Gx48-T modules
ifIndex allocation
The SNMP Management Information Base (MIB) uses the Interface Index (ifIndex) to assign a
unique value to each port on a module or slot.
If you will be installing the NI-MLX-1Gx48-T module on your device, you must configure the
maximum ifIndex per module to 64.
You must change the ifIndex allocation before installing
the NI-MLX-1Gx48-T module
; otherwise, the module remains in the Offline state.
If you have a new device (no previous software installed), and you will be installing an
NI-MLX-1Gx48-T module, you
must
configure the maximum ifIndex per module to 64;
otherwise, the module remains in the Offline state.
If you have a new device (no previous software installed), and will not be installing an
NI-MLX-1Gx48-T module, it is recommended that you configure the maximum ifIndex per
module to 64 to avoid future ifIndex problems if you decide to install an NI-MLX-1Gx48-T
module in the future.
Port MAC address change
The MAC address assigned to each port may change to accommodate a greater number of ports
per module. The MAC address ports allocated for each module has increased from 20 to 48.