Dell PowerConnect B - MLXe 16 Hardware Installation Guide - Page 150

Performing a coherence check without a reload, Displaying image versions, Using the show flash command

Page 150 highlights

6 Displaying image versions Performing a coherence check without a reload Enter the reload-check command to perform a coherence check without performing a reload, as shown in the following example: PowerConnect# reload-check Checking for coherence... Warning: The new LP PBIF-8X10 FPGA will not be compatible with the new LP 3 application. Warning: The new LP XPP-8X10 FPGA will not be compatible with the new LP 3 application. Done. PowerConnect# If interface modules are in interactive mode, or the system is unable to communicate with the interface modules, the system sends the following warning message. Can't check LP for coherence. Error messages generated by the coherence check The following error messages are generated if a coherence check fails: Warning: Image coherence check skipped due to insufficient info: Invalid active LP # flash images in Primary/Secondary. Warning: Image coherence check skipped due to insufficient info: Invalid active MP flash images in Primary/Secondary. Warning: Image coherence ckeck skipped due to insufficient info: MP/LP not booting from flash. Warning: Image coherence check skipped due to failure to communiate with LP. If interface modules are in interactive mode, or the system is unable to communicate with the interface modules, the system sends the following warning message. Can't check LP for coherence. Displaying image versions The following sections describe how to display software image version information for PowerConnect B-MLXe routers, using the show flash or show version commands. Using the show flash command You can display the images stored in flash memory using the show flash command. NOTE This example is for illustration only and may not reflect current image version information. Output from the show flash command resembles this example. PowerConnect# show flash 138 PowerConnect B-MLXe Hardware Installation Guide 53-1002111-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

138
PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01
Displaying image versions
6
Performing a coherence check without a reload
Enter the
reload-check
command to perform a coherence check
without
performing a reload, as
shown in the following example:
PowerConnect# reload-check
Checking for coherence...
Warning: The new LP PBIF-8X10 FPGA will not be compatible with the new LP 3
application.
Warning: The new LP XPP-8X10 FPGA will not be compatible with the new LP 3
application.
Done.
PowerConnect#
If interface modules are in interactive mode, or the system is unable to communicate with the
interface modules, the system sends the following warning message.
Can’t check LP for coherence
.
Error messages generated by the coherence check
The following error messages are generated if a coherence check fails:
Warning: Image coherence check skipped due to insufficient info: Invalid active LP
# flash images in Primary/Secondary.
Warning: Image coherence check skipped due to insufficient info: Invalid active MP
flash images in Primary/Secondary.
Warning: Image coherence ckeck skipped due to insufficient info: MP/LP not booting
from flash.
Warning: Image coherence check skipped due to failure to communiate with LP.
If interface modules are in interactive mode, or the system is unable to communicate with the
interface modules, the system sends the following warning message.
Can’t check LP for coherence
.
Displaying image versions
The following sections describe how to display software image version information for
PowerConnect B-MLXe routers, using the
show flash
or
show version
commands.
Using the show flash command
You can display the images stored in flash memory using the
show flash
command.
NOTE
This example is for illustration only and may not reflect current image version information.
Output from the
show flash
command resembles this example.
PowerConnect# show flash
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~