Icom VE-PG4 Operating Guide ver.1.36 - Page 212
RoIP Gateway Connection , Mode: RoIP Gateway, Destination Port Number
View all Icom VE-PG4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 212 highlights
7 Connection Port Settings RoIP Gateway screen Connection Port Settings > RoIP Gateway ■■RoIP Gateway Connection Mode: RoIP Gateway The settings for a destinations that are connected to the RoIP Gateway through the RoIP gateway connection. 1 21 3 4 5 6 7 8 LL6 is displayed only when the Transmission Mode (1) is set to "Multicast." 1 Transmission Mode ��� 2 Destination Address �� 3 Destination Port Number Select the transmission mode used on the network, for devices connected to the RoIP Gateway. Enter the IP address or domain of the RoIP Gateway that going to be connected. When the Transmission Mode (1) is set to "Multicast," automatically set to "239.255.255.1." Enter the same port number that entered to the Source Port Number (4) of the RoIP Gateway that going to be connected. (Default for RoIP Gateway1: 24400 Default for RoIP Gateway2: 24402 Default for RoIP Gateway3: 24404 Default for RoIP Gateway4: 24406 Default for RoIP Gateway5: 24408 Default for RoIP Gateway6: 24410 Default for RoIP Gateway7: 24412 Default for RoIP Gateway8: 24414) LLEnter the port number between 2 and 65534, in even number. LLDo not conflict with the other port settings. LLIn the Multicast mode, all the default setting are fixed to "25210." 7-58