Icom VE-PG4 Operating Guide ver.1.36 - Page 308
Hold Alarm
![]() |
View all Icom VE-PG4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 308 highlights
13 PBX Extension Telephone (KX-UT Series) screen PBX Extension > Telephone (KX-UT Series) ■■Hold Alarm Common Setting Sets the Hold alarm tone that sounds to alert you a second call has been held for certain period of time. 1 2 3 4 1 Frequency 1/2 2 Level 3 Repeat 4 Timing Set the tone frequencies of the Hold alarm. (Default: Frequency 1: 425 / Frequency 2: 0) •• Range: 0 (inaudible), 200 ~ 2000 (Hz) Set the audio level of the Hold alarm. •• Range: -24 (minimum) ~ +6 (maximum) (dB) (Default: 0) Set whether or not to repeat the set tone pattern. (Default: Enable) •• Disable: Sounds the set pattern in Timing (4) only once •• Enable: Continuously repeats the set pattern in Timing (4) •• Continuous Sound: Continuously sounds frequencies 1 and 2 (1) Set the pattern of tone rings and mutes using up to 9 values. The tone sounds for the set period of time in the ON settings, and mutes for the set period of time in the OFF settings. (Default: 120, 14880) •• Range of the first "OFF": 60 ~ 16000 (milliseconds) •• Range of the others: 51 ~ 16000 (milliseconds) 13-10