13 PBX Extension Telephone (KX-HDV Series) screen PBX Extension > Telephone (KX-HDV Series) ■■Dial Tone Common Setting Sets the tone when off-hook. 1 2 3 4 1 Frequency 1/2 2 Level 3 Repeat 4 Timing Set the tone frequencies of the Dial tone. (Default: Frequency 1: 350 / Frequency 2: 440) •• Range: 0 (inaudible), 200 ~ 2000 (Hz) LLThe 350 Hz and 440 Hz tones simultaneously sound at default. Set the audio level of the Dial tone. •• Range: -24 (minimum) ~ +6 (maximum) (dB) (Default: 0) Set whether or not to repeat the set tone pattern. (Default: Continuous Sound) •• Disable: Sounds the set pattern in Timing (4) only once •• Enable: Continuously repeats the set pattern in Timing (4) •• Continuous Sound: Continuously sounds frequencies 1 and 2 Set the pattern of tone rings and mutes using up to 9 values. The tone sounds for the set period of time in the ON settings, and mutes for the set period of time in the OFF settings. (Default: 60, 0) •• Range of the first "OFF": 60 ~ 16000 (milliseconds) •• Range of the others: 51 ~ 16000 (milliseconds) 13-23