6 Transceiver Controller Transceiver Settings screen Transceiver Controller > Transceiver Settings > Transceiver Settings ■■Transceiver Settings 10 11 12 13 14 15 16 17 18 LLThe screen shows when the Message (16) is set to "enable." 12 Volume (Except Reception Notice) Set the beep level when the IP100H is transmitting a Call or connecting to the RoIP Gateway, to between 0 and 32. (Default: 10) LLWhen this setting is set to "0," the notification beep is turned OFF. LLDepending on the [Common Settings], the IP100H sounds a beep when the IP100H is transmitting or connecting to the RoIP Gateway. 13 Communication Method � Select the communication method that the IP100H uses. (Default: Full-Duplex) •• Simplex: T oggles the transmission (Talker) and reception (Listener) for communication. •• Full-duplex: Simultaneously transmits and receives, like a telephone. LLWhen connecting the optional microphone to the IP100H, you can operate the IP100H like a telephone. Simplex and Full-duplex VE-PG4 Simplex IP100H Full-duplex Wireless access point 6-26