Icom VE-PG4 Operating Guide ver.1.36 - Page 218
Bridge Communication 
View all Icom VE-PG4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 218 highlights
7 Connection Port Settings RoIP Gateway screen Connection Port Settings > RoIP Gateway ■■Bridge Communication Mode: RoIP Gateway The settings for the Bridge Communication when a Bridge Connection Destination is set to "Custom Bridge Connection." (Bridge Connection Settings > Bridge Connection > Bridge Connection > Bridge Connection Destination) 1 2 3 4 5 6 78 1 Encryption 2 TalkBack 3 Call Type 4 Destination Prefix ID �� 5 Destination ID 6 Source ID 7
7
CONNECTION PORT SETTINGS
7-64
RoIP Gateway screen
Connection Port Settings > RoIP Gateway
■
Bridge Communication
Mode: RoIP Gateway
The settings for the Bridge Communication when a Bridge Connection Destination is set to “Custom Bridge Connection.”
(Bridge Connection Settings > Bridge Connection > Bridge Connection > Bridge Connection Destination)
1
Encryption �������
Select whether or not to enable the Encryption function, depending on
the connected transceiverʼs setting.
(Default: Disable)
When you enable the function, enter an encryption key between 1 and
32767.
(Default: 1)
2
TalkBack
��������
Select whether or not to enable the TalkBack function with devices
connected to the RoIP Gateway.
(Default: Enable)
When the function is enabled, Select the TalkBack time.
(Default: 5)
•
Range: 1 ~ 10 (seconds)
3
Call Type ��������
Select a call type.
(Default: Group)
•
Options: Individual, Group, or All
4
Destination Prefix ID ��
Enter a destination prefix ID. The ID may differ, depending on the
system.
•
Range: 0 ~30
5
Destination ID �����
Enter an Individual or Group ID for the destination transceiver between
1 and 9999999.
(Default: 1)
L
Enter an ID between 00001 and 99999 when the Destination Prefix ID (
4
) is
entered.
6
Source ID �������
Enter the stationʼs source ID between 1 and 9999999. Used for calling
transceivers connected to the serial port.
(Default: 1)
7
<Apply> ��������
Click to apply the settings.
8
<Reset> ��������
Click to reset the settings.
L
You cannot reset after clicking <Apply>.
8
7
2
1
3
4
5
6