Chapter 4 - Troubleshooting and Maintaining the Printer Fingerprint Error Messages (continued) Message Description Ready-to-Work Error Indicator Status Number LSS too low This error can occur when you run a test feed Blinking without any media installed, or if you have incorrect media settings. Load the printer with media and select the appropriate media type. For help, see "Loading Media" on page 7. Testfeed not done The printer did not perform a test feed before it Blinking printed out test labels. Performing a test feed calibrates the sensor. To perform a testfeed, press the A button. No RFID support installed The optional RFID interface is not installed in the Blinking printer. No tag found No RFID tag has been found. Blinking Pause Mode The print job is paused. Entered Blinking Setup Mode The printer is in Setup mode. Off Entered IP link error No network connection. Blinking IP The printer is trying to acquire an IP address from configuration the network. Wait for the printer to complete the error task before taking any action. Blinking Generic DP error In Direct Protocol, you can enable error handling for Blinking specific errors using the ERROR statement. When errors added to the built-in error handling occur, this event is set. The text included in the SNMP trap is the standard text corresponding to the error. Press any key If an error occurs in the Fingerprint immediate Off to continue mode, for example "out of paper" when the print key is pressed, this event is set. Application load error If an application is started but does not run, the Intermec Ready-to-Work indicator blinks. For example, if there is a syntax error in the loaded program file. Blinking RtW blink by This condition is set by the Fingerprint SYSHEALTH Blinking application command. For more information, see the Intermec Fingerprint Command Reference Manual. 1008 1606 1320 1321 108 PX4i and PX6i High Performance Printer User's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Chapter 4 — Troubleshooting and Maintaining the Printer
108
PX4i and PX6i High Performance Printer User’s Manual
LSS too low
This error can occur when you run a test feed
without any media installed, or if you have incorrect
media settings. Load the printer with media and
select the appropriate media type. For help, see
“Loading Media” on page 7
.
Blinking
1008
Testfeed not
done
The printer did not perform a test feed before it
printed out test labels. Performing a test feed
calibrates the sensor. To perform a testfeed, press the
A
button.
Blinking
1606
No RFID
support
installed
The optional RFID interface is not installed in the
printer.
Blinking
1320
No tag found
No RFID tag has been found.
Blinking
1321
Pause Mode
Entered
The print job is paused.
Blinking
Setup Mode
Entered
The printer is in Setup mode.
Off
IP link error
No network connection.
Blinking
IP
configuration
error
The printer is trying to acquire an IP address from
the network. Wait for the printer to complete the
task before taking any action.
Blinking
Generic DP
error
In Direct Protocol, you can enable error handling for
specific errors using the ERROR statement. When
errors added to the built-in error handling occur, this
event is set. The text included in the SNMP trap is
the standard text corresponding to the error.
Blinking
Press any key
to continue
If an error occurs in the Fingerprint immediate
mode, for example “out of paper” when the print key
is pressed, this event is set.
Off
Application
load error
If an application is started but does not run, the
Intermec Ready-to-Work indicator blinks. For
example, if there is a syntax error in the loaded
program file.
Blinking
RtW blink by
application
This condition is set by the Fingerprint SYSHEALTH
command. For more information, see the
Intermec
Fingerprint Command Reference Manual
.
Blinking
Fingerprint Error Messages (continued)
Message
Description
Ready-to-Work
Indicator Status
Error
Number