Yamaha DM1000 Owner's Manual - Page 353
MIDI Data Format, DATA FORMAT, Format Details
View all Yamaha DM1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 353 highlights
MIDI Data Format 353 MIDI Data Format 1. DATA FORMAT 1.1 CHANNEL MESSAGE Command 8n NOTE OFF 9n NOTE ON Bn CONTROL CHANGE Cn PROGRAM CHANGE rx/tx rx rx rx/tx rx/tx function Control the internal effects Control the internal effects Control parameters Switch scene memories 1.2 SYSTEM COMMON MESSAGE Command F1 MIDI TIME CODE QUARTER FRAME F2 SONG POSITION POINTER rx/tx rx MTC function rx Used when TIME REFERENCE is MIDI CLOCK. 1.3 SYSTEM REALTIME MESSAGE Command F8 TIMING CLOCK FA START FB CONTINUE FC STOP FE ACTIVE SENSING FF RESET rx/tx rx rx rx rx rx rx function MIDI clock Start automix (from the beginning) Start automix (from the middle) Stop automix Check MIDI cable connections Clear running status 1.4 EXCLUSIVE MESSAGE 1.4.1 Real Time System Exclusive Command F0 7F dd 06 ... F7 MMC COMMAND F0 7F dd 07 ... F7 MMC RESPONSE F0 7F dd 01 ... F7 MIDI TIME CODE rx/tx tx rx rx function MMC command MMC response MTC full message 1.4.2 System Exclusive Message 1.4.2.1 Bulk Dump Command F0 43 0n 7E ... F7 BULK DUMP DATA F0 43 2n 7E ... F7 BULK DUMP REQUEST rx/tx function rx/tx BULK DUMP DATA rx/tx BULK DUMP REQUEST The following data types of bulk dump are used on the DM1000. Data name 'm' 'S' 'a' 'R' 'O' 'H' 'G' 'Y' 'Q' 'E' 'J' 'K' 'P' 'C' 'L' 'V' 'U' 'N' tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx function Scene Memory & Request (compressed data) Setup Memory & Request Automix data & Request (compressed data) Input patch library & Request Output patch library & Request Channel library & Request Gate library & Request Compressor library & Request Equalizer library & Request Effect library & Request Bus to Stereo library & Request Surround Monitor library & Request Program change table & Request Control change table & Request User define layer & Request User define key & Request User assignable layer & Request Plug-in Effect Card Data & Request 1.4.2.2 PARAMTER CHANGE Command F0 43 1n 3E 0C ... F7 RARAMETER CHANGE F0 43 3n 3E 0C ... F7 PARAMETER REQUEST F0 43 1n 3E 7F ... F7 PARAMETER CHANGE F0 43 3n 3E 7F ... F7 PARAMETER REQUEST rx/tx function rx/tx DM1000-specific parameter change rx/tx DM1000-specific parameter change rx/tx rx/tx General purpose digital mixer parameter change General purpose digital mixer parameter request The following data types of parameter change are used by the DM1000. 1 (01) 2 (02) 3 (03) 4 (04) 15 (0F) 16 (10) 17 (11) 18 (12) 19 (13) 20 (14) 32 (20) 33 (21) 34 (22) 35 (23) 80 (50) Type (HEX) 84 (54) 126 (7E) 127 (7F) tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx rx rx tx/rx tx/rx rx tx/rx tx/rx tx/rx tx/rx tx/rx tx/rx tx function Edit buffer Patch data Setup data Backup data Cascade data Function (recall, store, title, clear) Function (pair, copy) Function (effect) Sort table Function (attribute, link) Key remote Remote meter Remote time counter Automix status Function response (recall, store, title, clear) Function response (attribute, link) System Attribute Active sense * 'tx' indicates that the data can be transmitted from the DM1000, and 'rx' indicates that the data can be received by the DM1000. 2. Format Details 2.1 NOTE OFF (8n) Reception If [OTHER ECHO] is ON, these message are echoed from MIDI OUT. If the [Rx CH] matches, these messages are received and used to control effects. STATUS DATA 1000nnnn 8n Note off message 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(ignored) 2.2 NOTE ON (9n) Reception If [OTHER ECHO] is ON, these messages are echoed from MIDI OUT. If the [Rx CH] matches, these messages are received and used to control effects. STATUS DATA 1001nnnn 9n Note on message 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(1-127:on, 0:off) 2.3 CONTROL CHANGE (Bn) Reception If [Control Change ECHO] is ON, these messages are echoed from MIDI OUT. If [TABLE] is selected, these message are received if [Control Change Rx] is ON, and will control parameters according to the [Control assign table] settings. The parameters that can be set are defined in the Control Change Assign Parameter List. If [NRPN] is selected, these messages are received if [Control Change Rx] is ON and the [Rx CH] matches, and will control the parameter that is specified by the four messages NRPN control number (62h, 63h) and Data Entry control number (06h, 26h). Parameter settings are defined in the Control Change Assign Parameter List. DM1000-Owner's Manual