- Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 1
OS10 Enterprise Edition User Guide - PowerEdge MX I/O Modules Release 10.4.0E(R3S) - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 2
and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 3
and license...22 Installation...23 Automatic installation...24 Manual installation...24 Log into OS10...25 Install OS10 license...26 Remote access...27 Configure Management IP address...27 Management Route Configuration...28 Configure user name and password...28 Upgrade OS10...29 CLI Basics...29 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 4
copy...49 default (alias)...51 delete...51 description (alias)...52 dir...52 discard...53 do...53 feature config-os9-style...53 exit...54 license...54 line (alias)...55 lock...55 management route...56 move...56 no...57 reload...57 show alias...57 show boot...59 show candidate-configuration...59 show - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 5
...93 Change hash algorithm...93 Configure interface ranges...93 Switch-port profiles...94 S4148-ON Series port profiles...95 S4148U-ON port profiles...96 Unified port groups...97 Configure breakout mode...99 Breakout auto-configuration...99 Reset default configuration...100 Forward error correction - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 6
(Fibre Channel)...128 speed (Management)...128 switch-port-profile...129 switchport access vlan...131 switchport mode...131 switchport trunk allowed vlan...132 unit-provision...132 4 Fibre channel...134 Fibre Channel over Ethernet...134 Configure FIP snooping...135 Terminology...136 Virtual fabric - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 7
zoneset)...147 name...147 show fc alias...148 show fc ns switch...148 show fc statistics...149 show fc switch...150 show fc zone...150 show fc zoneset...151 show default-zone permit...158 zoneset activate...158 5 Layer 2...159 802.1X...159 Port authentication...160 EAP over RADIUS...161 Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 8
Address Table...207 Clear MAC Address Table...207 MAC Commands...208 Multiple spanning-tree protocol...210 Configure MST protocol...211 Create instances...211 Root selection...213 Non-Dell hardware...213 Region name or revision...213 Modify parameters...214 Interface parameters...215 Forward traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 9
253 Default VLAN...253 Create or remove VLANs...254 Access mode...255 Trunk mode...256 Assign IP address...256 View VLAN configuration... path support...279 Advertise cost...279 4-Byte AS numbers...280 AS number migration...280 Configure border gateway protocol...281 Enable BGP...281 Configure Dual - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 10
commands...298 Equal cost multi-path...323 Load balancing...323 ECMP commands...323 IPv4 routing...326 Assign interface IP address...326 Configure static routing...327 Address resolution protocol...328 IPv4 routing commands...328 IPv6 routing...332 Enable or disable IPv6...332 IPv6 addresses...333 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 11
group priority...434 Authentication...435 Disable preempt...435 Advertisement interval...436 Interface/object tracking...437 Configure tracking...437 VRRP commands...438 7 UFT modes...444 Configure UFT modes...444 UFT commands...445 hardware forwarding-table mode...445 show hardware forwarding-table - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 12
449 Hostname resolution...450 Manual binding entries...451 DHCP ...472 Security...472 User re-authentication...473 Password strength...473 Role-based access control...474 Assign ...490 SNMP commands...490 Uplink Failure Detection...492 Configure uplink failure detection...493 UFD commands...494 OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 13
Permit ACL with L3 information only...506 Deny ACL with L3 information only...506 Permit all packets from host...506 Permit only first fragments and non-fragmented packets from host 506 Assign sequence number to filter...506 User-provided sequence number...507 Auto-generated sequence number...507 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 14
ip prefix-list permit...528 ip prefix-list seq deny...529 ip prefix-list seq permit...529 ipv6 access-group...530 ipv6 access-list...530 ipv6 prefix-list deny...530 ipv6 prefix-list description...531 ipv6 prefix-list permit...531 ipv6 prefix-list seq deny...532 ipv6 prefix-list seq permit...532 mac - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 15
next-hop...572 set origin...572 set tag...572 set weight...573 show route-map...573 10 Quality of service...574 Configure quality of service...574 Ingress traffic classification...576 Data traffic classification...576 Control-plane policing...580 Egress traffic classification...583 Policing traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 16
Modify packet fields...586 Shaping traffic...586 Bandwidth allocation...586 Strict priority queuing...587 Buffer management...588 Configure ingress buffer...589 Configure egress buffer...590 Congestion avoidance...590 Storm control...591 QoS commands...591 bandwidth...591 class...592 class-map...592 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 17
service-policy...607 set cos...607 set dscp...608 set qos-group...608 shape...609 623 VLT domain...623 VLT interconnect...624 Configure VLT...624 RSTP configuration...625 RPVST+ configuration...626 Create VLT domain...626 VLTi configuration...627 Configure VLT port-channel...627 VLT unicast routing - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 18
mode active-active...642 12 Converged data center services...643 Priority flow control...643 PFC configuration notes...644 Configure PFC...646 PFC commands...648 Enhanced transmission selection...651 ETS configuration notes...652 Configure ETS...652 ETS commands...654 Data center bridging eXchange - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 19
Port adapters and modules...688 Test network connectivity...688 View diagnostics...690 Diagnostic commands...691 Password recovery...702 Restore factory defaults...703 SupportAssist...703 Configure SupportAssist...704 Set company name...705 Set contact information...705 Schedule activity...706 View - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 20
15 Support resources...732 20 Contents - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 21
or universal serial bus (USB) media • Familiarity with any Linux release Supported Hardware The Dell EMC PowerEdge MX7000 supports the following Ethernet modules: • MX9116n Fabric Switching Engine • MX7116n Fabric Expander Module • MX5108n Ethernet Switch OS10 image for MX Ethernet I/O modules On - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 22
Switching Engine. Use the download and installation information in this chapter as reference to manually follow the instructions in Install Dell EMC ONIE-enabled device that does not have a default Service Tag of the switch to extend the entitled download period to be the same time as the support - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 23
an image over a network. To locate the Console port and the Management port, see the Getting Started Guide shipped with your device or the platform-specific Installation Guide at www.dell.com/support. Install OS10 If ONIE is installed on a device, navigate to the ONIE boot menu. An ONIE-enabled - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 24
an automatic or manual OS10 installation, if an error condition occurs that results in an unsuccessful installation, perform Uninstall OS first to clear the partitions if there is an existing OS on the device. If the problem persists, contact Dell EMC Technical Support. Automatic installation You - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 25
using USB drive You can manually install the OS10 software image using USB media. Verify that the USB storage device supports a FAT or EXT2 file system. For instructions on how to format a USB device in FAT or EXT2 format, see the accompanying Windows documentation for FAT formatting or Linux - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 26
license file in the Dell folder. Copy the port on the switch. • filepath/filename Service Tag : CFNNX42 License Details Software : OS10-Enterprise Version : 10.3.0E License Type : PERPETUAL License Duration: Unlimited License Status : Active License location: /mnt/license/CFNNX42.lic Troubleshoot - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 27
shell. When you install OS10 the first time, connect to the switch using the serial port. Configure remote access • Configure the Management port IP address • Configure a default route to the Management port • Configure a user name and password Remote access OS10 CLI 1 Open an SSH session using the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 28
configure a management route after you assign an IPv4 or IPv6 address to the Management port. The default supported. To increase the required password strength, use the password-attributes command. • Create a user name and password in CONFIGURATION mode. username username password password - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 29
configuration. A network operator cannot modify any configuration setting on a switch. Create user name and enter password in clear text OS10(config)# username user05 password 5 Read the Dell End User License switch with an installed OS10 license. See Install OS10 license for complete instructions - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 30
mode - Used to monitor, troubleshoot, check status, and network connectivity. • CONFIGURATION mode - Used to configure network devices. When you enter CONFIGURATION mode, you are changing the current operating configuration, called the running configuration. By default, all configuration changes are - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 31
by default. To access CONFIGURATION mode, enter the configure terminal command. Use CONFIGURATION mode to manage interfaces, protocols, and features. Interface mode is a sub-mode of CONFIGURATION mode. Interface mode is where you configure Layer 2 and Layer 3 protocols, and IPv4 and IPv6 services - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 32
filesystem No commands under exec mode ping -h shows help ping6 -h shows help Reboot Dell EMC Networking Operating System Show running system information Activate transaction based configuration Support Assist related activity System command Set terminal settings traceroute --help shows help Unlock - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 33
Spanning Tree Subsystem Support Assist feature configuration System configuration Configure telnet server settings Configure object tracking Configure trust Unit provision configuration Create or modify users VLT domain configurations Configure VRRP global attributes Configure WRED profile Check - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 34
-provision uptime users version vlan vlt vrrp Show sflow Show spanning tree information Contents of startup configuration Show storm control configuration Shows information about the support assist module Switch operating mode Show system status information Collection of show commands Show terminal - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 35
candidate sFlow configuration Current candidate snmp configuration Current candidate spanning-tree configuration Current candidate support-assist configuration Current candidate system-qos configuration Current candidate trust-map configuration Current candidate users configuration Current candidate - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 36
40g-1x ipv6 forwarding enable username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/VKx8SloIhp4NoGZs0I/ UNwh8WVuxwfd9q4pWIgNs5BKH. role sysadmin aaa authentication local snmp-server contact http://www.dell.com/support ! interface range ethernet 1/1/1-1/1/32 switchport access - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 37
40g-1x ipv6 forwarding enable username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/VKx8SloIhp4NoGZs0I/ UNwh8WVuxwfd9q4pWIgNs5BKH. role sysadmin aaa authentication local snmp-server contact http://www.dell.com/support ! interface range ethernet 1/1/1-1/1/32 switchport access - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 38
you enter the do commit command, the current session switches back to the default behavior of committing all configuration changes automatically. Save configuration changes manually OS10# start transaction OS10# configure terminal OS10(config)# OS10(config)# interface ethernet 1/1/1 OS10(config - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 39
configuration, copy a local or remote file to the startup configuration and reload the switch. After downloading a backup configuration, you must reload the system, otherwise the switch server OS10# copy config://startup.xml scp://userid:password@hostip/backup-9-28.xml Restore startup file from - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 40
commands, and execute long commands along with their parameters. The alias supports the following modes: • Persistent mode - The alias is persistent and can be used in other sessions as well. The aliases created in the Configuration mode are persistent. • Non-persistent mode - The alias can be used - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 41
Create alias OS10# alias showint "show interface $*" OS10(config)# alias goint "interface ethernet $1" View alias output for showint OS10# showint status Port Description Status Speed Duplex Mode Vlan Tagged-Vlans Eth 1/1/1 up 40G A 1 - Eth 1/1/2 up 40G A 1 - Eth 1/1/3 up 40G - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 42
an alias. Multi-line alias is supported only in the Configuration mode. You cannot use the exiting characters. • Create an alias in the CONFIGURATION mode. The switch enters the ALIAS mode. alias alias-name configuration" OS10(config-alias-mTest)# default 1 "ethernet" OS10(config-alias-mTest)# default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 43
saved in the multi-line alias OS10(config-alias-mTest)# show configuration ! alias mTest description InterfaceDetails default 1 ethernet default 2 1/1/1 line 1 "interface $1 $2" line 2 "no shutdown" line 3 "show configuration" line 4 exit View alias information OS10# show alias Name ---mTest Type - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 44
2 "no shutdown" line 3 "show configuration" default 1 "ethernet" default 2 "1/1/1" Batch mode commands You can file on the remote device to your switch, such as to your home directory. OS10# batch b.cmd OS10# Feb 15 19:26:1: %Dell EMC (OS10) %Node.1-Unit.1:PRI:OS10 %log-notice:IP_ADDRESS_ADD - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 45
BGP configuration executed by the batch file. admin@OS10:/opt/dell/os10/bin$ clish -c "show running-configuration supported only for show commands. • Enter the show command along with SSH. $ ssh admin@ip-address show-command $ ssh [email protected] "show version" [email protected]'s password: Dell - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 46
os9-style command. The current release supports VLAN tagging and port-channel grouping commands. • VLAN Interface mode - tagged - no tagged - untagged - no untagged • Port-channel Interface mode: - channel-member - no channel-member • Enable the feature to configure commands in an OS9 environment in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 47
1/1/1 OS10(conf-if-eth1/1/1)# Supported Releases 10.3.0E or later alias (multi-line) Creates a mulit-line command alias. Syntax alias alias-name Parameters Default Command Mode alias-name - Enter the name of the alias (up to 20 characters). Not configured CONFIGURATION Getting Started 47 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 48
Parameters filename - Enter the name of a batch command file. Default Not configured Command Mode EXEC Usage Information Use this command to create a batch command file on a remote machine. Copy the command file to your switch (for example, to your home directory). Enter the batch command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 49
OS10# commit Example (configuration) OS10(config)# do commit Supported Releases 10.2.0E or later configure Enters CONFIGURATION mode from EXEC mode. Syntax configure {terminal} Parameters terminal - Enters CONFIGURATION mode from EXEC mode. Default Not configured Command Mode EXEC Usage - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 50
supportbundle://filepath - (Optional) Copy from the support-bundle directory. • tftp://hostip/filepath - (Optional) Copy from a remote TFTP server. • usb:filepath - (Optional) Copy from an USB file system. Default Command Mode Usage Information Example Not configured EXEC Use this command to save - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 51
image, or startup configuration. Removing the startup configuration restores the system to factory default. You need to reboot the switch - reload for the operation to take effect. Use caution when removing the startup configuration. OS10# delete startup-configuration Supported Releases 10.2.0E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 52
image files. • supportbundle - (Optional) Folder containing support bundle files. • usb - (Optional) Folder containing files on USB drive. Default Command Mode Usage Information Example Not configured EXEC Use the dir config command to display configuration files. OS10# dir config coredump home - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 53
Releases 10.2.0E or later discard Discards any changes made to the candidate configuration file. Syntax discard Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# discard Supported Releases 10.2.0E or later do Executes most commands from all - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 54
later exit Returns to the next higher command mode. Syntax exit Parameters None Default Not configured Command Mode All Usage Information None Example OS10(conf-if-eth1/1/1)# exit OS10(config)# Supported Releases 10.2.0E or later license Installs a license file from a local or remote - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 55
, either in transaction or nontransaction-based configuration mode. Syntax Parameters Default Command Mode Usage Information Example lock None Not configured EXEC The lock command fails if there are uncommitted changes in the candidate configuration. OS10# lock Supported Releases 10.2.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 56
with the management interface. Default Command Mode Usage Information Example (IPv4) Not configured CONFIGURATION Management routes are separate from Example (IPv6) OS10(config)# management route 10::/64 10::1 Supported Releases 10.2.2E or later move Moves or renames a file on - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 57
-activity | terminal] • alias - Remove an alias definition. • debug - Disable debugging. • support-assist-activity - SupportAssist-related activity. • terminal - Reset terminal settings. Default Command Mode Usage Information Example Not configured EXEC Use this command in EXEC mode to disable or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 58
Supported Releases 10.3.0E or later Value ----"vlt-domain..." "interface ..." line 1 "interface ..." line 2 "no shutdow..." line 3 "show confi..." default 1 "ethernet" default " line 3 "show configuration" default 1 "ethernet" default 2 "1/1/1" "show running-configuration" "show interface $*" - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 59
Syntax show boot [detail] Parameters None Default Not configured Command Mode EXEC Usage Information The Next-Boot [A] Supported Releases 10.2.0E or later show candidate-configuration Displays the current candidate configuration file. Syntax Parameters show candidate-configuration [aaa - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 60
! Version 10.2.9999E ! Last configuration change at Apr 11 10:36:43 2017 ! username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 61
Example (compressed) OS10# show candidate-configuration compressed username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 62
-3 temp sensor 26 1 6 Switch board 2 temp sensor 31 1 7 Switch board 3 temp sensor 41 1 8 NPU temp sensor 43 Supported Releases 10.2.0E or later show inventory Displays system inventory information. Syntax show inventory Parameters None Default Not configured Command Mode EXEC - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 63
Connected Connected Supported Releases 10.2.2E Default Command Mode Usage Information Example show license status None Not configured EXEC Use this command to view the show license status command to verify the current license for running OS10, its duration, and the service tag of the switch - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 64
PPID : Service Tag : License Details Software : OS10-Enterprise Version : 10.3.9999E(X) License Type : EVALUATION License Duration: 120 days License Status : 45 day(s) left License location: /mnt/license/.lic Supported Releases 10.3.0E or later show running-configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 65
Example (compressed) OS10# show running-configuration compressed username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 66
Information None Example OS10# show startup-configuration username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States" ip - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 67
class-trust Supported Releases 10.2.0E or later show system Displays system information. Syntax Parameters show system [brief | node-id] • brief - View abbreviated list of system information. • node-id - Node ID number. Default Command Mode Usage Information Example Not configured EXEC None - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 68
up 2 12977 up 3 up NORMAL 1 13085 up 2 13063 up Example (node-id) OS10# show system node-id 1 fanout-configured Interface Breakout capable Breakout state Eth 1/1/1 Yes BREAKOUT_1x1 Eth 1/1/2 Yes BREAKOUT_1x1 Eth 1/1/3 Yes BREAKOUT_1x1 Eth 1/1/4 Yes BREAKOUT_1x1 Eth - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 69
NORMAL 1 12956 up 2 13063 up Supported Releases 10.2.0E or later show version Displays software version information. Syntax Parameters Default Command Mode Usage Information Example show version None Not configured EXEC None OS10# show version Dell EMC Networking OS10 Enterprise Copyright - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 70
OS10# system bash admin@OS10:~$ pwd /config/home/admin admin@OS10:~$ exit OS10# Supported Releases 10.2.0E or later system identifier Sets a non-default unit ID in a non-stacking configuration. Syntax system identifier system-identifier-ID Parameters system-identifier-ID - Enter the system - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 71
pausing. OS10# terminal monitor Supported Releases 10.2.0E or later out simultaneously to accelerate traceroute (default 16). - -t tos - (Optional) For IPv4, enter the Type of Service (TOS) and Precedence values default 60 bytes for IPv4 and 80 for IPv6). Default Not configured Getting Started 71 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 72
Usage Information Example EXEC None OS10# traceroute www.dell.com traceroute to www.dell.com (23.73.112.54), 30 hops ms Supported Releases 10.2.0E or later unlock Unlocks a previously locked candidate configuration file. Syntax unlock Parameters None Default Not configured Command Mode - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 73
Supported Releases 10.2.0E or later Getting Started 73 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 74
the OS10 CLI. For more information, see the Dell EMC OpenManage Enterprise - Modular documentation. Full Switch mode PowerEdge MX Ethernet switches operate in Full Switch mode by default. In Full Switch mode, all OS10 CLI commands and features supported by the hardware are available. 74 PowerEdge MX - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 75
and manage firmware. • View the physical topology. • Power control SmartFabric Services mode In SmartFabric Services mode, the PowerEdge MX switches operate as Layer 2 I/O aggregation devices. The OpenManage Enterprise Modular graphical user interface supports most switch configuration settings and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 76
configuration. Although front-panel port interfaces operate in L2 mode by default, L2 bridging is disabled. Verify configuration changes Module and MX5108n Ethernet Switch do not support port groups. Double-density QSFP28 interfaces On the MX9116n Fabric Switching Engine module, configure a double - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 77
interface connects only to an attached Fabric Expander using supported cables. • In native Ethernet mode, an interface connects to an upstream switch, rack server, or other Ethernet device. By default, QSFP28-DD port groups 1 to 9 are configured in FEM mode with 8x25GE breakout interfaces enabled - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 78
-1/1/29:4)# View QSFP28-DD interface OS10(config)# interface ethernet 1/1/29:4 OS10(conf-if-eth1/1/29:4)# show configuration ! interface ethernet1/1/29:4 no shutdown View QSFP28-DD port groups and default modes OS10# show port-group Port-group Mode Ports FEM port-group1/1/1 Eth 25g-8x 17 18 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 79
mode, you can perform the same switch configuration using the CLI as in SmartFabric mode using the graphical user interface, except that you must manually configure the unit ID of the Fabric Expander. The unit ID is also called the virtual slot ID. 1 Locate the service tag of the Fabric Expander in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 80
| SP0012 1 | 79 | 1 | 80 | 1 | 81 | 1 | 82 | SP0012 | | | | | | | | | | | | | | | | | | | up | | | | | | | | | 3 Configure the unit ID of the Fabric Expander with the service tag (provision name) in CONFIGURATION mode. OS10(config)# unit-provision node/unit-id - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 81
In the show interface status output, the Fabric Switching Engine 8x25GE interfaces that map to Fabric Expander virtual the virtual ports on the Fabric Expander that are up and connected to servers in CONFIGURATION mode. Unit IDs 71 to 82 are used as virtual slot numbers 1/71 to 1/82 on - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 82
-density QSFP28 interfaces On the MX9116n Fabric Switching Engine module, a QSFP28 port group consists of one Ethernet 100G port. By default, QSFP28 port groups 13 and 14 (physical ports 41 and 42) operate in 1x100GE mode. For information about how to configure QSFP28-DD port groups 1 to 12 to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 83
conf-if-eth1/1/41:4)# show configuration ! interface ethernet1/1/41:4 no shutdown View QSFP28 port groups and default modes OS10# show port- On the MX9116n Fabric Switching Engine and MX5108n Ethernet Switch, server-facing interfaces are internal and are enabled by default. To view the internal - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 84
true true true true View internal Ethernet port-server connections - MX5108n Ethernet Switch OS10# show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 FIXED INTERNAL true 1/1/2 FIXED INTERNAL true 1/1/3 FIXED - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 85
types Interface type Supported Ethernet (PHY) L2, L3 Management N/A Loopback L3 Port-channel L2, L3 VLAN L2, L3 Ethernet interfaces Default mode unset single MAC address. By default, all the interfaces operate in L2 mode. From L2 mode you can configure switching and L2 protocols, such - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 86
default, a trunk interface carries only untagged traffic on the Access VLAN. You must manually configure other VLANs for tagged traffic. 1 Select one of the two available options: • Configure 2 configuration before assigning an IP Fibre Channel interfaces OS10 unified port groups support Fibre - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 87
interfaces are available only in unified port groups 15 and 16 (ports 43 and 44). Figure 4. MX9116n Fabric Switching Engine - Unified port groups To enable a Fibre Channel interface: 1 Configure a unified port group in CONFIGURATION mode. Enter 1/1 for node/slot. The port-group range depends on the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 88
part of VLAN 4020. You cannot configure gateway addresses, IP addresses, and proxy ARPs on the management interface. VLAN interfaces VLANs are logical interfaces and are, by default, in L2 mode. Physical interfaces and port-channels can be members of VLANs. OS10 supports inter-VLAN routing. You can - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 89
configured default VLAN By default, VLAN1 serves as the default VLAN for switching untagged L2 traffic on OS10 ports in Trunk or Access mode. The default [os10:notify], %Dell EMC (OS10) %IFM_ASTATE_UP: Interface admin state up :vlan10 OS10(conf-if-vl-10)# exit OS10(config)# default vlan-id 10 Sep - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 90
Mode of IPv4 Address Assignment : MANUAL MTU 1532 bytes Flowcontrol rx false tx false Port-channels are not configured by default. Link aggregation (LA) supports a maximum of 128 port-channels, with up to thirty-two ports per channel. To configure a port-channel, use the same configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 91
member in the port-channel are automatically disabled. • An interface should not contain any non-default L2/L3 configuration settings - only the description and shutdown or no shutdowncommands are supported. You cannot add an IP address or a static MAC address to a member interface. • You cannot - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 92
up status. • Enter the number of links in a LAG that must be in oper up status in PORT-CHANNEL mode (1 to 32, default 1). minimum-links number Configure minimum operationally up links OS10(config)# interface po 1 OS10(conf-if-po-1)# minimum-links 5 Assign Port Channel IP Address You can assign an - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 93
. For packets without an L3 header, OS10 automatically uses the load-balancing mac-selection destination-mac command for hash algorithms by default. When you configure an IP and MAC hashing scheme at the same time, the MAC hashing scheme takes precedence over the IP hashing scheme. • Select - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 94
range vlan 1-100 OS10(conf-range-vl-1-100)# Configure range of port channels OS10(config)# interface range port-channel 1-25 OS10(conf-range-po-1-25)# Switch-port profiles A port profile determines the enabled front-panel ports and supported breakout modes on Ethernet and unified ports. Change the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 95
defaults, except for the switch-port profile and these configured settings: • Management interface 1/1/1 configuration • Management IPv4/IPv6 static routes • System hostname • Unified Forwarding Table (UFT) mode • ECMP maximum paths You must manually -ON unified port supports Fibre Channel and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 96
on these ports. For more information, see switch-port-profile. 1GE mode: 1GE is supported only on SFP+ ports; 1GE is not supported on QSFP+ and QSFP28 ports 25-26. Breakout interfaces: Use the interface breakout command in Configuration mode to configure 4x10G, 4x25G, and 2x50G breakout interfaces - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 97
group. In profile-2, by default SFP+ unified ports 1-24 come up in Ethernet 10GE mode. profile-1 allows you to connect FC devices for plug-and-play; profile-2 is designed for a standard Ethernet-based data network. **Oversubscription: Configure oversubscription to support bursty storage traffic on - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 98
default, and support Fibre Channel and other Ethernet modes. In Ethernet mode, unified port groups 15 and 16 contain different breakout options than QSFP28-DD and QSFP28 port groups 1 to 14. Figure 6. MX9116n Fabric Switching node/slot/port[:subport] Configure Ethernet unified port interface OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 99
direct attach cable (DAC) with 4x10G far-side transceivers into a QSFP28 port, the port autoconfigures in 10g-4x Interface-breakout mode. RJ-45 ports and ports that are members of a port group do not support breakout auto-configuration. Breakout auto-configuration is disabled by default. Interfaces - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 100
- After you enter feature auto-breakout and plug a breakout cable in Ethernet port 1/1/25: OS10# show interface status Port 1 - Eth 1/1/29 down 0 auto A 1 - Reset default configuration You can clear all configured settings on an Ethernet or Fibre Channel interface and reset the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 101
[os10:trap], %Dell EMC (OS10) %IP_ADDRESS_DEL: IP Address delete is successful. IP 10::1/64 deleted successfully OS10(config)# do show running-configuration interface ethernet 1/1/2 ! interface ethernet1/1/2 no shutdown switchport access vlan 1 Reset default Fibre Channel configuration OS10# show - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 102
NOTE: OS10 does not support FEC on 10G and 40G. Configure FEC OS10(config)# interface ethernet 1/1/41 OS10(conf-if-eth1/1/41)# fec CL91-RS View FEC configuration OS10# show interface ethernet 1/1/41 Ethernet 1/1/41 is up, line protocol is up Hardware is Dell EMC Eth, address is e4:f0:04:3e:1a:06 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 103
transmitting link partner. Enable energy-efficient Ethernet To reduce power consumption, enable EEE. EEE is disabled by default. 1 Enter the physical Ethernet interface information in CONFIGURATION mode. interface ethernet node/slot/port[:subport] 2 Enable EEE in INTERFACE mode. eee Enable EEE OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 104
EEE counters. Syntax Parameters Default Command Mode Usage Information Example clear counters interface eee None Not configured EXEC Use this command to clear all EEE counters. OS10# clear counters interface eee Clear all eee counters [confirm yes/no]:yes Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 105
(config)# interface ethernet 1/1/2 OS10(conf-if-eth1/1/2)# no eee Supported Releases 10.3.0E or later show interface eee Displays the EEE status for all interfaces. Syntax show interface eee Parameters None Default Not configured Command Mode EXEC Example OS10# show interface eee Port - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 106
] eee Parameters node/slot/port[:subport]-Enter the interface information. Default Not configured Command Mode EXEC Example OS10# show interface ethernet 1/1/48 eee Port EEE Status Speed Duplex Eth 1/1/48 on up 1000M Supported Releases 10.3.0E or later show interface ethernet eee - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 107
EEE : on TxIdleTime(us) : 2560 TxWakeTime(us) : 5 Last Clearing : 18:45:53 TxEventCount : 0 TxDuration(us) : 0 RxEventCount : 0 RxDuration(us) : 0 Supported Releases 10.3.0E or later View interface configuration To view basic interface information, use the show interface, show running- - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 108
oper status: Enabled Link local IPv6 address: fe80::20c:29ff:fe66:6b94/64 MTU 1532 bytes, IP MTU 1500 bytes LineSpeed 40G, Auto-Negotiation on Configured FEC is off, Negotiated FEC is off Flowcontrol rx off tx off ARP type: ARPA, ARP Timeout: 60 Last clearing of "show interface" counters: 02 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 109
16.153.226/24 YES manual up up Vlan 1 unassigned NO unset up down Vlan 10 unassigned NO unset up down Vlan 20 unassigned NO unset up down Vlan 30 unassigned NO unset up down View VLAN configuration OS10# show vlan Codes: * - Default VLAN, M - Management VLAN, R - Remote - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 110
Usage Information Example Not configured INTERFACE The no version of this command resets the value to the default, and unassigns the interface from the port-channel group. OS10(config)# interface ethernet 1/1/2:1 OS10(conf-if-eth1/1/2:1)# channel-group 20 mode active Supported Releases 10.3.0E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 111
command. • An Ethernet interface is assigned to the default VLAN. The default interface command removes all software settings and all L3, VLAN, and port-channel configurations on a physical interface. You must manually remove configured links to the interface from other software features; for - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 112
/1/1-1/1/4)# exit OS10(config)# default interface range ethernet 1/1/1,1/1/2-1/1/4 Dell EMC (OS10) %log-notice:IFM_OSTATE_UP: Interface operational state is up :vlan1 OS10(config)# interface range ethernet 1/1/1-1/1/4 OS10(conf-range-eth1/1/1-1/1/4)# show configuration Supported releases 10.4. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 113
Reconfigures the VLAN ID of the default VLAN. Syntax default vlan-id vlan-id Parameters vlan-id - Enter the default VLAN ID number (1 to 4093). Default VLAN 1 Command Mode CONFIGURATION Usage Information By default, VLAN 1 serves as the default VLAN for switching untagged L2 traffic on OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 114
and autoconfigure breakout interfaces. Syntax feature auto-breakout Parameters None Default Not configured Command mode CONFIGURATION Usage information After you enter the feature auto-breakout command and plug a supported breakout cable in a QSFP+ or QSFP28 port, the port autoconfigures - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 115
| CL108-RS | off} Parameters • CL74-FC - Supports 25G and 50G • CL91-RS - Supports 100G • CL108-RS - Supports 25G and 50G • off - Disables FEC Defaults • For 25G and 50G interfaces: off • For 100G interfaces: CL91-RS Command Mode Usage Information CONFIGURATION The no version of this command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 116
OS10(conf-if-ma-1/1/1)# Supported Releases 10.2.0E or later interface null Configures a null interface on the switch. Syntax interface null number Parameters number - Enter the interface number to set as null (0). Default 0 Command Mode CONFIGURATION Usage Information You cannot delete - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 117
Default Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command deletes the interface. OS10(config)# interface port-channel 10 OS10(conf-if-po-10)# Supported Releases 10.2.0E or later interface range Configures a range of Ethernet, port-channel, or VLAN - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 118
the interface. OS10(config)# interface vlan 10 OS10(conf-if-vl-10)# Supported Releases 10.2.0E or later link-bundle-utilization Configures link-bundle utilization. Syntax Parameters Default Command Mode Usage Information Example link-bundle-utilization trigger-threshold value value - Enter - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 119
-pg-1/1/2)# mode Eth 10g-4x Supported Releases 10.3.1E or later mode l3 After you configure the VLAN scale profile, enables L3 routing on a VLAN. Syntax mode l3 Parameters None Defaults Not configured Command Mode INTERFACE VLAN Usage Information To configure the VLAN scale profile, use - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 120
bytes. Example OS10(conf-if-eth1/1/7)# mtu 3000 Supported Releases 10.2.0E or later port-group Configures a group of front-panel unified ports, or a depends on the switch. Default Command mode Usage information Not configured CONFIGURATION Enter PORT-GROUP mode to: • Configure unified ports - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 121
port-group 1/1/8 OS10(conf-pg-1/1/8)# Supported releases 10.3.1E or later scale-profile vlan Configures the L2 VLAN scale profile on a switch. Syntax Parameters Defaults Command Mode Usage Information Example scale-profile vlan None Not configured CONFIGURATION Use the VLAN scale profile when - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 122
Supported number (1 to 4093). Default Command Mode Usage Information Example Not configured EXEC Use the do show interface command to view interface information from other command modes. OS10# show interface Ethernet 1/1/2 is up, line protocol is up Hardware is Dell - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 123
12 (Inact) 23 L2 up 20:34:32 Eth 1/1/20 (Up) Eth 1/1/21 (Up) Eth 1/1/22 (Up) Supported Releases 10.2.0E or later show inventory media Displays installed media in switch ports. Syntax Parameters Command Mode Usage Information Example show inventory media None EXEC Use the show inventory media - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 124
-bundle utilization. Syntax show link-bundle-utilization Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# show link-bundle-utilization Link-bundle trigger threshold - 60 Supported Releases 10.2.0E or later show port-channel summary Displays - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 125
1/1/11(P) 1/1/14(P) 1/1/16(P) 1/1/19(P) 23 port-channel23 (D) Eth STATIC Supported Releases 10.2.0E or later show port-group Displays the current port-group configuration on a switch. Syntax show port-group Parameters None Default None Command Mode EXEC Usage Information To view the ports - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 126
show switch-port-profile 1/1 | Node/Unit | Current | Next-boot | Default | | 1/1 | profile-2 | profile-2 | profile-1 | Supported Profiles: profile-1 profile-2 profile-3 profile-4 profile-5 profile-6 Supported Releases 10.3.1E or later show unit-provision Displays the unit ID and service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 127
provision None EXEC If the Fabric Switching Engine is in Full Switch mode, you must manually configure the unit ID of an attached Fabric Expander (see Virtual ports). Use the show unit-provision command to display the assigned and unassigned unit IDs, and service tag (provision name) values. Use the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 128
oversubscription. • The no version of this command resets the port speed to the default value auto. Example OS10(conf-if-fc-1/1/2)# speed 16 Supported Releases 10.3.1E or later speed (Management) Configures the transmission speed of the Management interface. Syntax Parameters speed {10 | 100 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 129
. Defaults Command Mode Usage Information Auto INTERFACE The speed command is supported only on the Management and Fibre Channel interfaces. This command is not supported on Ethernet interfaces. • When you manually configure the management port speed, match the speed of the remote device. Dell EMC - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 130
to the startup configuration, and reload the switch. The switch reboots with new port configuration. The no version of the command resets to the default profile. When a switch reloads with a new port profile, the startup configuration resets to system defaults, except for the switch-port profile and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 131
paths You must manually reconfigure other settings on a switch after you apply a new port profile and reload the switch. Example OS10(config)# switch-port-profile 1/1 profile-1 Warning: Switch port profile will be applied only after a save and reload. All management port configurations will be - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 132
mode command. If a Fabric Engine is in Full Switch mode, you must manually provision a Fabric Expander using the unitprovision command. This command assigns a unit ID to a service tag (provision name). To transmit server traffic, you must configure the virtual port on the Fabric Expander by entering - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 133
• The no version of the command removes the Fabric Expander provisioning. Example OS10(config)# unit-provision 1/78 403RPK2 Supported Releases 10.4.0E(R3S) or later Interfaces 133 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 134
port that connects the Fibre Channel (FC) fabric to a node. S4148U-ON switches support F_Port. Enable Fibre channel F_Port mode globally using the feature fc domain-ID domain-ID command in CONFIGURATION mode. Enable Fibre channel F_Port mode OS10(config)# feature fc domain-id 100 N_Port A node - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 135
-100)# fip-snooping fc-map 0xEFC64 OS10(conf-if-vl-100)# exit OS10(config)# fcoe max-sessions-per-enodemac 64 View FIP snooping configuration details OS10# show fcoe statistics interface vlan 100 Number of Vlan Requests :0 Number of Vlan Notifications :0 Number of Multicast Discovery Solicits - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 136
of Session failures due to Hardware Config :0 OS10# show fcoe vlan * = Default VLAN VLAN FC-MAP FCFs Enodes Sessions *1 - - - - 100 0X0EFC00 byte address used by FC to identify the end points A 3-byte prefix configured per VLAN, used to frame FCoE MAC address Fibre Channel Forwarder Fibre - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 137
the vfabric, configure FCoE parameters, configure the default zone, and activate the zoneset. NOTE: Do not associate a VLAN that is already in use, as a vfabric VLAN. Configure vfabric in F_Port mode 1 Configure a vfabric using the vfabric fabric-ID command in CONFIGURATION mode. The switch enters - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 138
Switch Zoning Parameters Default Zone Mode: Allow Active ZoneSet: set Members fibrechannel1/1/1 fibrechannel1/1/30:3 Configure vfabric in NPG mode 1 Configure a vfabric using the vfabric fabric-ID command in CONFIGURATION mode. The switch enters vfabric CONFIGURATION mode. Enter - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 139
allows communication between all the possible pairs of FC nodes. When the default-zone action is not configured, the switch denies any communication between FC nodes. Configure FC zoning OS10(config)# fc zone hba1 OS10(config-fc-zone-hba1)# member wwn 10:00:00:90:fa:b8:22:19 OS10(config-fc- - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 140
-zoneset-set)# exit OS10(config)# vfabric 100 OS10(conf-vfabric-100)# zoneset activate set OS10(conf-vfabric-100)# zone default-zone permit View FC zone configuration OS10(config-fc-zone-hba1)# show configuration ! fc zone hba1 member wwn 21:00:00:24:ff:7b:f5:c8 member wwn 10:00:00:90:fa - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 141
address of FCF. • fcoe-mac-address - Enter the MAC address of FCoE session. Default Command Mode Usage Information Example Not configured EXEC None OS10# clear fcoe database vlan 100 enode aa:bb:cc:00:00:00 Supported Releases 10.4.0E(R1) or later clear fcoe statistics Clears FCoE statistics for - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 142
cb:6f:65:57 Supported Releases 10.3.1E or later fc zone Creates an FC zone and adds members to the zone. An FC zone can have a maximum of 527 unique members. Syntax fc zone zone-name Parameters zone-name - Enter a name for the zone. Defaults Not configured Command Mode CONFIGURATION Usage - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 143
$, _, -, ^ Defaults Not configured Command Mode CONFIGURATION Usage Information The no version of this command removes the FC zoneset. Example OS10(config)# fc zoneset set OS10(conf-fc-zoneset-set)# member hba1 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 144
sessions to be allowed, ranging from 1 to 64. Defaults 32 Command Mode CONFIGURATION Usage Information The no version of this command resets the number of sessions to the default value. Example OS10(config)# fcoe max-sessions-per-enodemac 64 Supported Releases 10.4.0E(R1) or later feature fc - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 145
12 VLANs. Example OS10(config)# interface vlan 3 OS10(conf-if-vl-3)# fip-snooping enable Supported Releases 10.4.0E(R1) or later fip-snooping fc-map Configure the FC map value for specific VLAN. Syntax Parameters Defaults fip-snooping fc-map fc-map fc-map - Enter the FC map ID, ranging from - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 146
1/1/32 OS10(conf-if-eth1/1/32)# fip-snooping port-mode fcf Supported Releases 10.4.0E(R1) or later member (alias) Add members to • fc-id - Enter the FC ID name. Defaults Command Mode Usage Information Not configured Alias CONFIGURATION The no version of this command removes the member from - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 147
21:00:00:24:ff:7b:f5:c8 Supported Releases 10.3.1E or later member (zoneset) Adds zones to an existing zoneset. Syntax member zone-name Parameters zone-name - Enter an existing zone name. Defaults Not configured Command Mode Zoneset CONFIGURATION Usage Information The no version of this - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 148
24:ff:7b:f5:c9 20:25:78:2b:cb:6f:65:57 OS10# Supported Releases 10.3.1E or later show fc ns switch Displays the details of FC NS switch parameters. Syntax show fc ns switch [brief] Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# show fc ns - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 149
Switch Name Domain Id Switch Port FC-Id Port Name Node Name Class of Service :b8:22:19 21:00:00:24:ff:7b:f5:c8 Supported Releases 10.3.1E or later show fc statistics Displays the FC channel interface name. Default Command Mode Usage Information Example (vfabric) Not configured EXEC None OS10# - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 150
1E or later show fc switch Displays the FC switch parameters. Syntax show fc switch Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# show fc switch Switch Mode : FPORT Switch WWN : 10:00:14:18:77:20:8d:cf Supported Releases 10.3.1E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 151
Supported Releases 10.3.1E or later 21:00:00:24:ff:7f:ce: fc zoneset [active | zoneset-name] Parameters zoneset-name - Enter the FC zoneset name. Default Not configured Command Mode EXEC Usage Information None Example OS10# show fc zoneset ZoneSetName ZoneName ZoneMember set hba1 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 152
100 1 5 Supported Releases 10.4.0E(R1) or later show fcoe fcf Displays the details of FCFs connected to the switch. Syntax show fcoe [fcf-mac-address] Parameters fcf-mac-address - (Optional) Enter the MAC address of FCF. This option displays details of specified FCF. Default Not configured - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 153
displays the sessions established on the specified VLAN. Default Not configured Command Mode EXEC Usage Information None Example OS10# :00 Supported Releases 10.4.0E(R1) or later show fcoe statistics Displays the statistical details of FCoE control plane. Syntax Parameters Default Command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 154
Not configured Command Mode EXEC Usage Information None Example OS10# show fcoe vlan * = Default VLAN VLAN FC-MAP FCFs Enodes Sessions *1 - - - - 100 0X0EFC00 1 2 17 Supported Releases 10.4.0E(R1) or later show npg devices Displays the NPG devices connected to the switch. Syntax - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 155
Eth 1/1/31 20:01:d4:ae:52:1a:f8:9c 100 Fc 1/1/20 10 FLOGI LOGGED_IN Supported Releases 10.4.0E(R1) or later show running-config vfabric Displays the running configuration for vfabric. Syntax Parameters Defaults Command Mode Usage Information Example show running-config vfabric None Not - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 156
Default Not configured Command Mode EXEC Usage Information None Example OS10# show vfabric Fabric Name 100 Fabric Type FPORT Fabric Id 100 Vlan Id 1023 FC-MAP 0xEFC64 Config-State ACTIVE Oper-State UP Switch /1/30:1 fibrechannel1/1/30:3 Supported Releases 10.3.1E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 157
OS10(config)# vfabric 100 Supported Releases 10.3.1E or later vfabric (interface) Applies an existing vfabric to an FC interface. Syntax Parameters Defaults Command Mode Usage Information vfabric fabric-ID fabric-ID - Enter the fabric ID, from 1 to 255. Not configured INTERFACE The no version - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 158
OS10(config)# vfabric 100 OS10(conf-vfabric-100)# vlan 1023 Supported Releases 10.3.1E or later zone default-zone permit Enables access between all logged-in FC nodes of vfabric in the absence of an active zoneset configuration. A default zone advertises a maximum of 527 members in the registered - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 159
-tree plus for faster convergence and interoperability (see RPVST+ Commands). Rapid Spanning-Tree Faster convergence and interoperability with devices configured with the spanning-tree and multiple spanning-tree Protocol (RSTP) protocols (see RSTP Commands). Virtual LANs (VLANs) Improved - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 160
NOTE: OS10 supports only RADIUS as the back-end authentication server. The authentication process based on the results of the authentication process. The authenticator is executed on the Dell device. • Authentication-server - The authentication-server selects the authentication method, verifies - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 161
packets as an attribute of type, length, value (TLV) format - the type value for EAP messages is 79. Configure 802.1X You can configure and enable 802.1X on a port in a single process. OS10 supports 802.1X with EAP-MD5, EAP-OTP, EAP-TLS, EAP-TTLS, PEAPv0, PEAPv1, and MS-CHAPv2 with PEAP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 162
mode. interface range 3 Enable 802.1X on the supplicant interface only in INTERFACE mode. dot1x port-control auto Configure and verify 802.1X configuration OS10(config)# dot1x system-auth-control OS10(config)# interface range 1/1/7-1/1/8 OS10(conf-range-eth1/1/7-1/1/8)# dot1x port-control auto - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 163
when the request arrived, there may be a physical layer problem, and so on. 1 Configure the amount of time that the authenticator waits before re-transmitting INTERFACE mode (1 to 65535 - 1 year, default 60). dot1x timeout tx-period seconds 2 Configure a maximum number of times the authenticator re- - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 164
authenticator waits to re-transmit a Request Identity frame after a failed authentication in INTERFACE mode (1 to 65535, default 60 seconds). dot1x timeout quiet-period seconds Configure and verify port authentication OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout quiet-period 120 OS10(conf-range - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 165
communicates on the network. • Place a port in the Auto, Force-authorized (default), or Force-unauthorized state in INTERFACE mode. dot1x port-control {auto | force-authorized | force-unauthorized} Configure and verify force-authorized state OS10(conf-range-eth1/1/7-1/1/8)# dot1x port-control - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 166
If the supplicant or the authentication server is unresponsive, the authenticator terminates the authentication process after 30 seconds by default. Configure the amount of time the authenticator waits for a response before termination. • Terminate the authentication process due to an unresponsive - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 167
Initialize View interface running configuration OS10(conf-range-eth1/1/7-1/1/8)# do show running-configuration interface ... ! interface -auth - Allows 802.1X authentication for each connected host. Default Command Mode Usage Information Example Multi-host INTERFACE The no version of this - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 168
restarting 802.1X reauthentication (1 to 10). 2 INTERFACE The no version of this command resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x max-req 4 Supported Releases 10.2.0E or later dot1x port-control Controls the 802.1X authentication performed on the interface. Syntax - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 169
Command Mode INTERFACE Usage Information The no version of this command resets the value to the default. Example OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout quiet-period 120 Supported Releases 10.2.0E or later dot1x timeout re-authperiod Sets the number of seconds between re-authentication - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 170
version of this command resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout tx-period 120 Supported Releases 10.2.0E or later show dot1x Displays global 802.1X configuration information. Syntax Parameters Default Command Mode Usage Information Example show dot1x None - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 171
the Ethernet interface information. EXEC Use this command to view the dot1x interface configuration for a specific interface. OS10# show dot1x interface 802.1x information on ethernet1 id: 1 Auth PAE State: Initialize Backend State: Idle Supported Releases 10.2.0E or later Layer 2 171 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 172
a dynamically created LAG. The interfaces restore and are ready for configuration. • A maximum of 128 port-channels with up to 16 members per channel are allowed. Configuration LACP is enabled globally by default. You can configure aggregated ports with compatible active and passive LACP modes to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 173
lacp rate fast no shutdown ! ... Interfaces Create a LAG and then add LAG member interfaces. By default, all interfaces are in no shutdown and switchport modes. 1 Create a LAG in CONFIGURATION mode. interface port-channel port-channel number 2 Enter INTERFACE mode. interface ethernet node/slot/port - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 174
K - Distribution enabled, L - Distribution disabled, M - Partner Defaulted, N - Partner Non-defaulted, O - Receiver is in expired state, P - Receiver is Priority 32768 Sample configuration This sample topology is based on two routers - Alpha and Bravo. Alpha LAG configuration summary OS10(config - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 175
51)# channel-group 1 mode active Alpha verify LAG port configuration OS10# show lacp port-channel Port-channel 1 admin up , L - Distribution disabled, M - Partner Defaulted, N - Partner Non-defaulted, O - Receiver is in expired state, part of Port-channel Hardware is Dell EMC Eth, address is 90:b1 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 176
Link, F - Individual Link, G - IN_SYNC, H - OUT_OF_SYNC, I - Collection enabled, J - Collection disabled, K - Distribution enabled, L - Distribution disabled, M - Partner Defaulted, N - Partner Non-defaulted, O - Receiver is in expired state, P - Receiver is not in expired state Port ethernet1/1/29 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 177
State=BCEGIKNP Partner Oper State=BDEGIKNO LACP commands channel-group Assigns and configures a physical interface to a port-channel group. Syntax Parameters channel-group is 128. The maximum physical port/maximum NPU is supported. • mode - Enter the interface port-channel mode. Layer 2 177 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 178
1/1/11 OS10(conf-if-eth1/1/11)# channel-group 10 mode active Supported Releases 10.2.0E or later clear lacp counters Clears the statistics for all the LACP port-channel number (1 to 128). Default Command Mode Usage Information Example Not configured EXEC If you use this command for a static - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 179
compatible ports from aggregating, or when you have more than eight ports configured for the channel group. When setting the priority, a higher number returns the port priority to the default value. OS10(conf-range-eth1/1/7-1/1/8)# lacp port-priority 32768 Supported Releases 10.2.0E or later lacp - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 180
command resets the system priority to the default value. OS10(config)# lacp system-priority 32768 Supported Releases 10.2.0E or later show lacp the LACP channel group number (1 to 128). Default Command Mode Usage Information Example Not configured EXEC All channel groups display if you do not - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 181
Default Command Mode Usage Information Example show lacp interface ethernet node/slot/port node/slot/port - Enter the interface information. Not configured EXEC The LACP_activity field displays if you configure State=BCEGIKNP Partner Oper State=BDEGIKMO Supported Releases 10.2.0E or later show - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 182
number for the LACP neighbor (1 to 128). Default Command Mode Usage Information Example Not configured EXEC All channel groups display if you do not 1 Partner Oper State:aggregation synchronization collecting distributing defaulted expired Supported Releases 10.2.0E or later show lacp port - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 183
system that runs LACP has an LACP system priority value. The default value is 32768 or configure a value between 1 and 65535. LACP uses the system priority is enabled by default on OS10 interfaces. • An LLDP-enabled interface can support up to eight neighbors. An OS10 switch supports a maximum of - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 184
valid. - Optional Includes sub-types of TLVs that advertise specific configuration information. These sub-types are management TLVs, IEEE 802.1, IEEE 802.3, and TIA-1057 organization-specific TLVs. Optional TLVs OS10 supports basic TLVs, IEEE 802.1, and 802.3 organizationally-specific TLVs, and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 185
the current duplex and bit rate settings of the sending device. Also configuration/status indicates whether the current settings are due to auto-negotiation or due to manual configuration. 127 - Power via MDI Not supported. 127 - Maximum frame size Maximum frame size capability of the MAC and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 186
endpoint devices and network connectivity devices to advertise their characteristics and configuration information. LLDP-MED endpoint devices are located at the IEEE 802 LAN network edge and participate in IP communication service using the LLDPMED framework, such as IP phones and conference bridges - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 187
3 Network connectivity Reserved Network policies TLVs A network policy in the context of LLDP-MED is a device's VLAN configuration and associated Layer 2 and Layer 3 configurations. LLDP-MED network policies TLV include: • VLAN ID • VLAN tagged or untagged status • Layer 2 priority • DSCP value - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 188
voice services. 4 - Guest voice signaling Used only if guest voice control packets use a separate network policy than voice data. 5 - SoftPhone voice Used for softphone application on a device like PC or laptop. This class does not support multiple VLANs and if required, is configured to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 189
120 Reinit-time in seconds: 2 Transmit interval in seconds: 60 Configure LLDPDU intervals OS10(config)# lldp holdtime-multiplier 2 OS10(config)# do : 2 Transmit interval in seconds: 30 Disable and re-enable LLDP By default, LLDP is enabled for each interface and globally. You can disable LLDP on - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 190
LLDP globally OS10(config)# no lldp enable Disable and re-enable LLDP on management ports By default, LLDP is enabled on management ports. You can disable or enable the following LLDP configurations on management ports. 1 Disable the LLDPDU transmit or receive. no lldp transmit no lldp receive - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 191
Configure default. Configure OS10 to advertise LLDP-MED TLVs out of configured network-policy on an interface in CONFIGURATION mode. lldp-med network-policy index number (1 to 32). Configure advertise LLDP-MED network policies OS10 MED fast start period. By default, the device sends three packets per - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 192
during activation in CONFIGURATION mode (1 to 10, default 3). lldp-med fast-start-repeat-count number Configure fast start repeat count OS10(config)# lldp med fast-start-repeat-count 5 View LLDP configuration • View the LLDP configuration in EXEC mode. show running-configuration • View LLDP error - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 193
, Bridge, Router Enabled System Capabilities: Repeater, Bridge, Router Remote Max Frame Size: 0 Remote Aggregation Status: false MAC PHY Configuration: Auto-neg supported: 1 Auto-neg enabled: 1 Auto-neg advertised capabilities: 10BASE-T half duplex mode, 10BASE-T full duplex mode, 100BASE-TX half - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 194
Number : B11G152 Manufacturer : Dell Model : S6010-ON Asset default multiplier is 4, with a default TTL of 120 seconds. 1 Adjust the TTL value in CONFIGURATION mode. lldp holdtime-multiplier 2 Return to the default multiplier value in CONFIGURATION mode. no lldp holdtime-multiplier Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 195
Command Mode Usage Information Example clear lldp counters None Not configured EXEC The counter default value resets to zero for all physical interfaces. OS10# clear lldp counters Supported Releases 10.2.0E or later clear lldp table Clears LLDP neighbor information for all interfaces. Syntax - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 196
X (Hold Time Multiplier). The no version of this command resets the value to the default. OS10(config)# lldp holdtime-multiplier 2 Supported Releases 10.2.0E or later lldp med fast-start-repeat-count Configures the number of packets sent during the activation of the fast start mechanism. Syntax - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 197
Supported Releases 10.2.0E or later lldp med network-policy Manually defines an LLDP-MED network policy. Syntax - Enter the DSCP value set for the application. Default Command Mode Usage Information Example Not configured CONFIGURATION You can create up to 32 network policies and attach - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 198
lldp med tlv-select network-policy Supported Releases 10.2.0E or later lldp receive Enables or disables the LLDP packet reception on a specific interface. Syntax Parameters Default Command Mode Usage Information Example lldp receive None Not configured INTERFACE Enable LLDP globally on the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 199
lldp timer seconds seconds - Enter the LLDP timer rate in seconds (5 to 254). 30 seconds CONFIGURATION The no version of this command sets the LLDP timer back to its default value. OS10(config)# lldp timer 25 Supported Releases 10.2.0E or later lldp tlv-select basic-tlv Enables or disables TLV - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 200
/1/3)# lldp tlv-select dot3tlv macphy-config Supported Releases 10.2.0E or later lldp transmit Enables the transmission of LLDP packets on a specific interface. Syntax Parameters Default Command Mode Usage Information Example lldp transmit None Not configured INTERFACE The no version of this - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 201
Bridge Router System description: Dell networking Operating system Port Supported Releases 10.2.0E or later show lldp errors Displays the LLDP errors related to memory allocation failures, queue overflows, and table overflows. Syntax show lldp errors Parameters None Default Not configured - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 202
Total Input Queue Overflows: 0 Total Table Overflows: 0 Supported Release 10.2.0E or later show lldp med Displays the LLDP MED information for all the interfaces. Syntax Parameters Default Command Mode Usage Information Example show lldp med None Not configured EXEC Use the show lldp interface - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 203
, Bridge, Router Enabled System Capabilities: Repeater, Bridge, Router Remote Max Frame Size: 0 Remote Aggregation Status: false MAC PHY Configuration: Auto-neg supported: 1 Auto-neg enabled: 1 Auto-neg advertised capabilities: 10BASE-T half duplex mode, 10BASE-T full duplex mode, 100BASE-TX half - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 204
Revision : 10.1.9750B Serial Number : B11G152 Manufacturer : Dell Model : S6010-ON Asset ID : E1001 Power-via-MDI Supported Releases 10.2.0E or later show lldp timers Displays the LLDP hold time, delay time, and update frequency interval configuration information. Syntax Parameters Default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 205
port-vlan mac-phy-config link-aggregation max-frame-size Supported Releases 10.2.0E or later show lldp traffic Displays LLDP ) Enter the Ethernet interface information to view the LLDP traffic. Default Not configured Command Mode EXEC Usage Information None Example OS10# show lldp traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 206
(0 to 1000000, default 1800). mac address-table aging-time seconds Configure Aging Time OS10(config)# mac address-table aging-time 900 Disable Aging Time OS10(config)# mac address-table aging-time 0 Static MAC Address A static MAC address entry is one that you manually configure. A static entry - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 207
Set Static MAC Address OS10(config)# mac address-table static 34:17:eb:f2:ab:c6 vlan 10 interface ethernet 1/1/5 MAC Address Table OS10 maintains a list of MAC address table entries. • View the contents of the MAC address table in EXEC mode. show mac address-table {dynamic | static} [address mac- - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 208
Example (VLAN) OS10# clear mac address-table dynamic vlan 20 Supported Releases 10.2.0E or later mac address-table aging-time Configures the aging time for entries in the L2 address table. Syntax Parameters Default Command Mode Usage Information Example mac address-table aging-time seconds - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 209
CONFIGURATION The no version of this command resets the value to the default. OS10(config)# mac address-table static 34:17:eb:f2:ab:c6 vlan 1 interface ethernet 1/1/30 Example (PortChannel) OS10(config)# mac address-table static 34:17:eb:02:8c:33 vlan 10 interface port-channel 1 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 210
Type Interface 1 66:38:3a:62:31:3a dynamic ethernet1/1/3 Supported Releases 10.2.0E or later Multiple spanning-tree protocol MST is an RSTP-based spanning-tree variation that improves on per-VLAN RPVST+. You can configure MST instances and map multiple VLANs to one spanning-tree instance to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 211
)# spanning-tree mode mst OS10(config)# do show spanning-tree show spanning-tree mst configuration Region Name: ravi Revision: 0 MSTI VID 0 1,7-4093 1 2 2 3 3 4 4 5 5 6 Add or remove interfaces By default, all interfaces are enabled in L2 switchport mode, and all L2 interfaces are - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 212
, Address 3417.4455.667f Root Bridge hello time 2, max age 20, forward delay 15, max hops 20 Bridge ID Priority 32768, Address 90b1.1cf4.a523 Configured hello time 2, max age 20, forward delay 15, max hops 20 CIST regional root ID Priority 32768, Address 90b1.1cf4.a523 CIST external path cost - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 213
1cf4.a523 Configured hello time supports only one MST region. For a bridge to be in the same MST region as another, the three unique attributes (name, revision, and VLAN-to-instance-mapping) must match. The default values for name and revision number match on all Dell hardware. If you have non-Dell - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 214
15). spanning-tree mst forward-time seconds 2 Change the hello-time parameter in CONFIGURATION mode (1 to 10, default 2). Dell EMC recommends increasing the hello-time for large configurations (especially configurations with more ports). spanning-tree mst hello-time seconds 3 Change the max-age - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 215
Change the port priority of an interface in INTERFACE mode (0 to 240 in increments of 16, default 128). spanning-tree msti number priority priority View MSTi interface configuration OS10(conf-if-eth1/1/7)# do show spanning-tree msti 0 interface ethernet 1/1/7 ethernet1/1/7 of MSTI 0 is Designated - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 216
enforcing the active network topology. OS10 supports BPDU filtering, BPDU guard, root instructs the hardware to drop BPDUs and prevents flooding from reaching the CPU. BPDU filtering is enabled by default on Edge ports. All BPDUs received on the Edge port are dropped. If you explicitly configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 217
OS10(conf-if-eth1/1/4)# do show spanning-tree interface ethernet 1/1/4 ethernet1/1/4 of vlan1 is designated Blocking Edge port:no (default) port guard :none (default) Link type is point-to-point (auto) Boundary: NO bpdu filter : Enable bpdu guard : bpduguard shutdown-on- violation :disable - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 218
ethernet1/1/4 of vlan1 is root Forwarding Edge port:no (default) port guard :none (default) Link type is point-to-point (auto) Boundary: extra MST instances in the Sending or Received logs, an additional MST instance was configured on one router but not others. • View BPDUs in EXEC mode. debug - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 219
receive (rx) to enable the debug direction. • events - Debugs PVST events. Default Command Mode Usage Information Example Not configured EXEC None OS10# debug spanning-tree bpdu rx Supported Releases 10.2.0E or later instance Configures MST instances and one or multiple VLANs mapped to the MST - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 220
OS10(conf-mst)# name my-mst-region Supported Releases 10.2.0E or later revision Configures a revision number for the MSTP configuration. Syntax revision number Parameters number - Enter a revision number for the MSTP configuration (0 to 65535). Default 0 Command Mode MULTIPLE-SPANNING-TREE - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 221
-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree disable Disables the spanning-tree mode configured with the spanning-tree mode command globally on the switch or on specified interfaces. Syntax spanning-tree disable Parameters None Default Not configured. Usage - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 222
• rapid-pvst - Sets the STP mode to RPVST+. Default Command Mode Usage Information Example (RSTP) RPVST+ CONFIGURATION All STP instances are stopped in the previous STP mode, spanning-tree mode mst Supported Releases 10.2.0E or later spanning-tree mst Configures an MST instance and determines - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 223
spanning-tree msti 1 cost 3 Supported Releases 10.2.0E or later spanning-tree mst configuration Enters MST mode to configure MSTP from Configuration mode. Syntax spanning-tree mst configuration Parameters None Default Disabled Command Mode CONFIGURATION Usage Information Use this command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 224
BPDUs transmitted by MST to STP. • rstp - Forces the version for the BPDUs transmitted by MST to RSTP. Default Command Mode Usage Information Example Not configured CONFIGURATION Forces a bridge that supports MST to operate in a STP-compatible mode. OS10(config)# spanning-tree mst force-version - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 225
(1 to 10). 2 seconds CONFIGURATION Dell EMC recommends increasing the hello-time for large configurations - especially configurations with multiple ports. The no version of this command resets the value to the default. OS10(config)# spanning-tree mst hello-time 5 Supported Releases 10.2.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 226
Example OS10(config)# spanning-tree port type edge Supported Releases 10.2.0E or later show spanning-tree mst Displays MST configuration information. Syntax show spanning-tree mst configuration Parameters None Default Not configured Command Mode EXEC Usage Information Enable MSTl prior - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 227
1 2 2 3 3 4 4 5 5 6 Supported Releases 10.2.0E or later show spanning-tree msti Displays MST - Enter the port-channel interface information (1 to 128). Default Command Mode Usage Information Example (Brief) Not configured EXEC View the MST instance information for a specific MST - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 228
-VLAN spanning-tree plus RPVST+ is an RSTP to create a single topology per VLAN. RPVST+ is enabled by default, provides faster convergence, and runs on the default VLAN (VLAN 1). Configuring Rapid-PVST+ is a four-step process: 1 Ensure the interfaces are in L2 mode. 2 Place the interfaces in VLANs - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 229
all physical and port-channel interfaces to the default VLAN (VLAN1). • Enable the Rapid-PVST+ mode in CONFIGURATION mode. spanning-tree mode rapid-pvst Configure RPVST+ OS10(config)# spanning-tree mode rapid-pvst View RPVST+ configuration OS10# show spanning-tree active Spanning tree enabled - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 230
- priority priority-value - Enter the priority value in increments of 4096, default is 32768. The lower the number assigned, the more likely this bridge 4097, Address 90b1.1cf4.a523 We are the root of VLAN 1 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 231
according to the lowest bridge ID. Assign one bridge as root bridge and the other as a secondary root bridge. • Configure the device as the root or secondary root in CONFIGURATION mode. spanning-tree vlan vlan-id root {primary | secondary} - vlan-id - Enter the VLAN ID number (1 to 4093). - primary - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 232
Port enabled with loop guard conditions • Loop guard is supported on any STP-enabled port or port-channel interface in RPVST configuration information before it refreshes information by recomputing the RPVST+ topology. • Modify the forward-time (in seconds) in CONFIGURATION mode (4 to 30, default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 233
seconds) in CONFIGURATION mode (1 to 10, default 2). With large configurations (involving more number of ports), Dell EMC recommends increasing the hello-time. spanning-tree vlan vlan-id hello-time seconds • Modify the max-age (in seconds) in CONFIGURATION mode (6 to 40, default 20). spanning-tree - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 234
- Enter transmit (tx) or receive (rx) to enable the debug direction. • events - Debugs PVST events. Default Command Mode Usage Information Example Not configured EXEC None OS10# debug spanning-tree bpdu rx Supported Releases 10.2.0E or later show spanning-tree vlan Displays RPVST+ status and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 235
128.296 0000.0000.0000 128.300 0000.0000.0000 128.304 Supported Releases 10.2.0E or later spanning-tree bpdufilter Enables or disables BPDU . • disable - Disables the BPDU guard filter on an interface. Default Command Mode Usage Information Example Disabled INTERFACE BPDU guard prevents a port - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 236
mode to none. Default Usage Information Command Mode Example Not configured Root guard and loop guard configurations are mutually exclusive. Configuring one overwrites the other from the active configuration. INTERFACE OS10(conf-if-eth1/1/4)# spanning-tree guard root Supported Releases 10.2.0E - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 237
config)# spanning-tree mode mst Supported Releases 10.2.0E or later spanning-tree port Sets the port type as the EdgePort. Syntax spanning-tree port type edge Parameters None Default Not configured Command Mode INTERFACE Usage Information When you configure an EdgePort on a device running - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 238
transmitted by RPVST+ to STP. • rstp - Forces the version for the BPDUs transmitted by RPVST+ to RSTP Default Command Mode Usage Information Example Not configured CONFIGURATION Forces a bridge that supports RPVST+ to operate in a STP-compatible mode. OS10(config)# spanning-tree mst force-version - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 239
in seconds (1 to 10). Default Command Mode Usage Information Example 2 seconds CONFIGURATION Dell EMC recommends increasing the hello-time for large configurations - especially configurations with multiple ports. OS10(config)# spanning-tree vlan 10 hello-time 5 Supported Releases 10.2.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 240
bridge. Example OS10(conf-if-eth1/1/4)# spanning-tree vlan 10 priority 16 Supported Releases 10.2.0E or later spanning-tree vlan root Designates a device as primary - Designate the bridge as secondary or secondary root bridge. Default Command Mode Not configured CONFIGURATION 240 Layer 2 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 241
OS10(config)# spanning-tree vlan 1 root primary Supported Releases 10.2.0E or later Rapid spanning-tree protocol RSTP is similar to STP but provides faster convergence and interoperability with devices configured with STP and MSTP. RSTP is disabled by default. All enabled interfaces in L2 mode are - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 242
20, forward delay 15 Bridge ID Priority 32768, Address 90b1.1cf4.a523 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name values set on other bridges participating in the RSTP group. Dell EMC recommends that only experienced network administrators change the RSTP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 243
15). spanning-tree rstp forward-time seconds • Change the hello-time in CONFIGURATION mode (1 to 10, default 2). With large configurations (especially those configurations with more ports) Dell EMC recommends increasing the hello-time. spanning-tree rstp hello-time seconds • Change the max-age - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 244
. • Assign a number as the bridge priority or designate it as the primary or secondary root in CONFIGURATION mode. Configure the priority value range (0 to 65535 in multiples of 4096, default 32768). The lower the number assigned, the more likely this bridge becomes the root bridge. spanning-tree - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 245
enforcing the active network topology. OS10 supports BPDU filtering, BPDU guard, loop instructs the hardware to drop BPDUs and prevents flooding from reaching the CPU. BPDU filtering is enabled by default on Edge ports. All BPDUs received on the Edge port are dropped. If you explicitly configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 246
by STP. Enabling loop guard on a per port basis enables it on all VLANs configured on the port. If you disable loop guard on a port, it is moved to 1/1/4 ethernet1/1/4 of vlan1 is designated Blocking Edge port:no (default) port guard :none (default) Link type is point-to-point (auto) Boundary: NO - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 247
counters for a port-channel interface (1 to 128). Default Command Mode Usage Information Example Not configured EXEC Clear all STP counters on the device per port-channel 10 Supported Releases 10.2.0E or later show spanning-tree active Displays the RSTP configuration and information for - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 248
No ethernet3/1/4 Altr 128.256 128 500 BLK 0 AUTO No Supported Releases 10.2.0E or later show spanning-tree interface Displays spanning- Displays detailed information on the interface. Default Command Mode Usage Information Example Not configured EXEC None OS10# show spanning-tree interface - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 249
-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree disable Disables the spanning-tree mode configured with the spanning-tree mode command globally on the switch or on specified interfaces. Syntax spanning-tree disable Parameters None Default Not configured. Usage - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 250
mode to none. Default Usage Information Command Mode Example Not configured Root guard and loop guard configurations are mutually exclusive. Configuring one overwrites the other from the active configuration. INTERFACE OS10(conf-if-eth1/1/4)# spanning-tree guard root Supported Releases 10.2.0E - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 251
act as EdgePorts. OS10(config)# spanning-tree port type edge Supported Releases 10.2.0E or later spanning-tree rstp force-version Configures a forced version of spanning tree to transmit BPDUs. Syntax Parameters Default Command Mode Usage Information Example spanning-tree rstp force-version stp - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 252
CONFIGURATION Dell EMC recommends increasing the hello-time for large configurations (especially configurations with multiple ports). OS10(config)# spanning-tree rstp hello-time 5 Supported to 65535. The default value is 0. Default Not configured Command Mode CONFIGURATION Usage Information The - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 253
CONFIGURATION RSTP determines the root bridge but you can assign one bridge a lower priority to increase the probability it being the root bridge. A lower priority value increases the probability of the bridge becoming a root bridge. OS10(config)# spanning-tree rstp priority 200 Supported switches - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 254
(no interface vlan vlan-id command), any interfaces assigned to that VLAN are assigned to the default VLAN as untagged interfaces. Configure a port-based VLAN, enter INTERFACE-VLAN mode for VLAN related configuration tasks and create a VLAN. Assign interfaces in L2 mode to the VLAN to enable it - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 255
VLAN before you can assign the port in Access mode to that VLAN. Use the no switchport access vlan command to reset to default VLAN. 1 Configure a port in INTERFACE mode. interface ethernet node/slot/port[:subport] 2 Set the interface to Switchport mode as access in INTERFACE mode. switchport mode - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 256
The traffic between the ports in different VLANs route using the IP address. Configure the L3 VLAN interface to remain administratively UP or DOWN using the shutdown L2 traffic. You cannot assign an IP address to the default VLAN (VLAN 1). You can place VLANs and other logical interfaces in L3 mode to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 257
eight secondary IP addresses). Assign IP address to VLAN OS10(config)# interface vlan 200 OS10(conf-if-vl-200)# ip address 10.1.15.1/8 View VLAN configuration OS10(conf-if-vl-200)# do show interface vlan Vlan 1 is up, line protocol is up Address is , Current address is Interface index is 69208865 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 258
View VLAN configuration OS10# show vlan Codes: * - Default VLAN, G-GVRP VLANs, R-Remote Port Mirroring VLANs, P-Primary, C-Community, Queueing strategy: fifo Time since last interface status change: View interface configuration for specific VLAN OS10# show interface vlan 320 Vlan 320 is up - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 259
vlan vlan-id Parameters vlan-id - Enter the VLAN ID number (1 to 4093). Default VLAN 1 Command Mode CONFIGURATION Usage Information FTP, TFTP, MAC ACLs, and SNMP operations are not supported - IP ACLs are supported on VLANs only. The no version of this command deletes the interface. Example - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 260
up T Eth1/1/25:4 1/1/32 T Po40 A Eth1/1/3:1 Supported Releases 10.2.0E or later Port monitoring Port monitoring enables monitoring switch to one or more ports on the same switch. For local port monitoring, the monitored source and monitoring destination ports are on the same device. Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 261
port monitoring helps network administrators monitor and analyze traffic to troubleshoot network problems in a time-saving and efficient way. In a configure each intermediate switch that participates in the transport of monitored traffic with the reserved L2 VLAN. Remote port monitoring supports - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 262
monitoring VLAN. Valid VLAN IDs are from 2 to 4093. The default VLAN ID is not supported. • In monitored traffic, packets that have the same destination MAC traffic must be a L2 VLAN - L3 VLANs are not supported. Configure remote port monitoring Remote port monitoring requires a source interface ( - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 263
. • If the destination IP address is not reachable, the session goes down. • OS10 does not support ERPM destination session and decapsulation of ERPM packets at the destination switch. • You can configure a maximum of 4 ERPM sessions with a maximum of 128 source ports in each session. You can - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 264
mode. exit 3 Create an access list in CONFIGURATION mode. ip access-list access-list-name 4 Define access-list rules using seq, permit, and deny statements in CONFIG-ACL mode. The ACL rules describe the traffic you want to monitor. Flow monitoring is supported for IPv4 ACLs, IPv6 ACLs, and MAC ACLs - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 265
an orphan port or VLT LAG or VLTi member port to VLT LAG. The packet analyzer is connected to the TOR switch. Recommendation The following is an example of recommended configuration on the peer VLT device: 1 Create RSPAN VLAN ! interface vlan 100 no shutdown remote-span ! 2 Create an L2 ACL for the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 266
VLT LAG of TOR, or any port in the TOR to any orphan port - in the VLT device. Configure VLT nodes as intermediate device. The packet analyzer is connected to the TOR switch. Mirror VLT LAG to any orphan port on the same VLT device. The packet analyzer is connected to the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 267
session (1 to 4093). Not configured MONITOR-SESSION The no version of this command resets the value to the default. OS10(conf-mon-local-10)# destination interface port-channel 10 OS10(conf-mon-rspan-source-3)# destination remote-vlan 20 Supported Releases - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 268
-3)# flow-based enable Supported Releases 10.2.0E or later ip Configures the IP time to live (TTL) value and the differentiated services code point (DSCP) an encapsulated remote monitoring session. Default Command Mode Usage Information Example local CONFIGURATION The no version of this command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 269
ID number (1 to 18). • all - View all monitoring sessions. Default Command Mode Usage Information Example (specific session) All EXEC In the State field both port 11.11.11.1 2.2.2.1 0 2 session does not exist Supported Releases 10.2.0E or later shut Disables the monitoring session. The - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 270
VLAN. • rx - Monitor only received packets. • tx - Monitor only transmitted packets. This option is not supported in VLAN. Default Command Mode Usage Information Example Not configured MONITOR-SESSION None OS10(config)# monitor session 1 OS10(conf-mon-local-1)# source interface ethernet 1/1/7 rx - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 271
Default Command Mode Usage Information Example Not configured MONITOR-SESSION None OS10(config)# monitor session 10 OS10(conf-mon-erpm-source-10)# source-ip 10.16.132.181 destination-ip 172.16.10.11 gre-protocol 35006 Supported Releases 10.4.0E(R1) or later Layer 2 271 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 272
the IPv6 address space, stateless auto-configuration, header format simplifications, and improved support for options and extensions (see IPv6 connections from one network to another. An ISP uses a transit AS to sell transit service to a customer network. When BGP operates inside an AS - AS1 or AS2, - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 273
Classless interdomain routing BGPv4 supports classless interdomain routing (CIDR) with aggregate routes and AS paths. CIDR defines a network using a prefix consisting of an IP address and mask, resulting in efficient - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 274
the same outbound policies. Instead of manually configuring each neighbor with the same policy, template provides efficient update calculation with simplified configuration. Peer templates also aid in convergence ) is an extension to BGP that supports multiple address families-IPv4 and IPv6. MBGP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 275
information is exchanged over the IPv4 peers and vice versa. BGP routers that support IPv6 can set up BGP sessions using IPv6 peers. If the existing BGP if the first AS in the AS_SEQUENCE is the same for both paths. • Configure the bgp always-compare-med command to compare MEDs for all paths. • Paths - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 276
metric to the BGP next-hop. 7 The system deems the paths as equal and only performs the following steps if the criteria are not met: • Configure the IBGP multipath or EBGP multipath using the maximum-path command. • The paths being compared were received from the same AS with the same number - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 277
into BGP. The question mark (?) indicates an origin code of INCOMPLETE, and the lower case letter (i) indicates an origin code of IGP. Origin configuration OS10# show ip bgp BGP local RIB : Routes to be Added , Replaced , Withdrawn BGP local router ID is 30.1.1.1 Status codes: s suppressed - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 278
and continues until it reaches the end of the list. When you configure the non-deterministic-med command, paths are compared in the order they arrive -MED may or may not get compared between the adjacent paths. By default, the bestpath as-path multipath-relax command is disabled. This prevents BGP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 279
process. BGP add-path also helps switch over to the next new best path default. BGPv4 and BGPv6 support • Deterministic MED, default • A path with a missing MED is treated as worst path and assigned an 0xffffffff MED value • Delayed configuration at system boot - OS10 reads the entire configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 280
4-Byte AS numbers OS10 supports 4-byte AS number configurations by default. The 4-byte support is advertised as a new BGP Router A, it must maintain the connection with Router C without immediately updating Router C's configuration. Local-AS allows Router B to appear as if it still belongs to Router - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 281
seconds • holdtime = 180 seconds Add-path Disabled Enable BGP BGP is disabled by default. The system supports one AS number - you must assign an AS number to your device. To establish BGP sessions and route traffic, configure at least one BGP neighbor or peer. In BGP, routers with an established - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 282
reachable. 1 Assign an AS number, and enter ROUTER-BGP mode from CONFIGURATION mode (1 to 65535 for 2-byte, 1 to 4294967295 for 4byte). Only one AS number is supported per system. If you enter a 4-byte AS number, 4-byte AS support is enabled automatically. router bgp as-number 2 Enter a neighbor in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 283
! Configure Dual Stack OS10 supports dual stack for BGPv4 and BGPv6. Dual stack BGP allows simultaneous exchange of same IPv4 or IPv6 prefixes through different IPv4 and IPv6 peers. You can enable dual stack using the activate command in the corresponding address-family mode. By default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 284
for the template. NOTE: An outbound filter policy, distribute list or route map, is not supported on a peer group member. 1 Enable BGP, and assign the AS number to the local BGP speaker in CONFIGURATION mode, from 1 to 65535 for 2 byte, 1 to 4294967295 | 0.1 to 65535.65535 for 4 byte, or 0.1 to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 285
support enabled Number of peers in this group 1 Peer-group members: View running configuration OS10(config-router-neighbor)# do show running-configuration /local address, BGP brings the session down. By default, the hold time governs a BGP session. Configure BGP fast fall-over on a per-neighbor or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 286
Local host: 3.1.1.3, Local port: 58633 Foreign host: 3.1.1.1, Foreign port: 179 Verify neighbor fall-over on peer-group OS10# show running-configuration ! router bgp 102 ! address-family ipv4 unicast aggregate-address 6.1.0.0/16 ! neighbor 40.1.1.2 inherit template bgppg no shutdown ! neighbor 60 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 287
Fast external fallover is enabled by default. To disable or re-enable it, use the [no] -if-eth1/1/1)# View fast external fallover unconfiguration OS10(config-router-bgp-300)# do show running-configuration bgp ! router bgp 300 no fast-external-fallover ! neighbor 3.1.1.1 remote-as 100 no - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 288
[os10:event], %Dell EMC (OS10) %BGP_NBR_BKWD_STATE_CHG: Backward state change occurred Hold Time expired for Nbr:3.1.1.3 VRF:default Apr 27 01:39 configure a BGP device in Peer-Listening mode, a session with a dynamic peer comes up. Passwords are not supported on BGPv4/v6 dynamic peers. Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 289
allow-as parameter permits a BGP speaker to allow the AS number for a configured number of times in the updates received from the peer. The AS-PATH times in ROUTER-BGP-NEIGHBOR-AF mode (1 to 10). allowas-in number Configure AS number appearance OS10(config)# router bgp 10 OS10(conf-router-bgp-10)# - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 290
router-bgp-neighbor-af)# allowas-in 1 OS10(config-router-bgp-neighbor-af)# end OS10# show running-configuration bgp ! router bgp 100 ! neighbor 172:16:1::2 remote-as 100 no shutdown ! address-family ipv6 ospf Additional paths The add-path command is disabled by default. 290 Layer 3 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 291
. To change the LOCAL_PREF value in ROUTER-BGP mode from 0 to 4294967295 with default 100, use the default local preference value command. To view the BGP configuration, use the show running-configuration command. A more flexible method for manipulating the LOCAL_PREF attribute value is to use - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 292
{in | out) 6 Enter the peer group to apply the route map configuration in ROUTER-BGP mode. template template-name 7 Apply the route map to the Set a weight value for the route in ROUTER-NEIGHBOR mode (1 to 4294967295, default 0). weight weight 3 Return to ROUTER-BGP mode. exit 4 Assign a weight - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 293
)# weight 200 Enable multipath You can have one path to a destination by default, and enable multipath to allow up to 64 parallel paths to a destination. the amount of BGP control traffic. With route reflection configured properly, IBGP routers are not fully meshed within a cluster but all receive routing - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 294
the no bgp client-to-client reflection command in ROUTER-BGP mode. You must fully mesh all the clients before you disable route reflection. Configure BGP route reflector OS10(config)# router bgp 102 OS10(conf-router-bgp-102)# cluster-id 4294967295 OS10(conf-router-bgp-102)# neighbor 32.1.1.2 OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 295
the mesh for IBGP peers is to configure BGP confederations. As with route reflectors, Dell EMC recommends BGP confederations only for IBGP . You cannot have a mix of router ASN support. confederation peers as-number [... as-number] Configure BGP confederations OS10(config)# router bgp 65501 OS10( - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 296
the flapping route again advertises or is no longer suppressed (1 to 20000, default 750). Withdrawn routes are removed from the history state. • suppress - Number reset it by using the clear ip bgp command in EXEC mode. Configure values to reuse or restart route OS10(config)# router bgp 102 OS10( - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 297
the router dead (3 to 65535, default 180). View nondefault values OS10# show running-configuration ... neighbor 32.1.1.2 remote-as 103 soft reconfiguration, or soft reset without preconfiguration, both BGP peers must support the soft route refresh capability. The soft route refresh advertises in the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 298
commands activate Enables the neighbor or peer group to be the current address-family identifier (AFI). Syntax activate Parameters None Default Not configured Command Mode ROUTER-BGP-NEIGHBOR-AF Usage Information This command is used for exchanging IPv4 or IPv6 address family information - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 299
to the peer, from 2 to 64. Default Command Mode Usage Information Example (IPv4) Not configured ROUTER-BGP-NEIGHBOR-AF Advertising multiple paths to bgpv6-af)# add-path receive Supported Releases 10.2.0E or later address-family Enters global address family configuration mode for the IP address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 300
to send the BGP OPEN message, from 0 to 240. Default Not configured Command Mode ROUTER-NEIGHBOR Usage Information The time interval applies to time interval. Example OS10(conf-router-neighbor)# advertisement-start 30 Supported Releases 10.3.0E or later aggregate-address Summarizes a range - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 301
the best path. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# always-compare-med Supported Releases 10.2.0E or later bestpath as-path Configures the AS path selection criteria for best path computation. Syntax Parameters bestpath as-path {ignore - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 302
version of this command disables configuration. OS10(conf-router-bgp-10)# bestpath as-path multipath-relax Supported Releases 10.3.0E or later missing-as-worst - Treat missing MED as the least preferred path. Default Command Mode Usage Information Example Disabled ROUTER-BGP Before you apply this - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 303
an IPv6 address to clear a BGP neighbor configuration. • * - Clears all BGP sessions. Default Command Mode Usage Information Example Not configured EXEC To reset BGP IPv4 or IPv6 neighbor sessions, use this command. OS10# clear ip bgp 1.1.15.4 Supported Releases 10.3.0E or later clear ip bgp - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 304
in a cluster. Example OS10(conf-router-bgp-2)# client-to-client reflection Supported Releases 10.2.0E or later bgp connection-retry-timer Configures a peer connection retry timer. Syntax Parameters Default Command Mode Usage Information Example bgp connection-retry-timer seconds seconds - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 305
. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# cluster-id 3.3.3.3 Supported Releases 10.3.0E or later bgp dampening Enables BGP route-flap dampening and configures the dampening parameters. Syntax bgp dampening [half-life | reuse-limit | suppress - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 306
command setting within the AS. The no version of this command removes local preference value. Example OS10(conf-router-bgp-1)# default local-preference 200 Supported Releases 10.3.0E or later ebgp-multihop Allows EBGP neighbors on indirectly connected networks. Syntax ebgp-multihop hop count - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 307
OS10(conf-router-bgp-1)# enforce-first-as Supported Releases 10.3.0E or later fall-over Enables or disables BGP session fast fall-over for BGP neighbors. Syntax Parameters Default Command Mode Usage Information Example fall-over None Disabled ROUTER-NEIGHBOR Configure the BGP fast fall-over on - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 308
. This only applies after you manually reset all existing BGP sessions. For the configuration to take effect, use the Supported Releases 10.3.0E or later inherit template Configures a peer group template name that the neighbors use to inherit peer-group configuration. Syntax Parameters Default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 309
AS numbers. The no version of this command resets the value to the default. Example (Neighbor) OS10(conf-router-bgp-10)# neighbor lunar OS10(conf OS10(conf-router-bgp-10)# log-neighbor-changes Supported Releases 10.3.0E or later maximum-paths Configures the maximum number of equal-cost paths for - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 310
64. Default Command Mode Usage Information Example (EBGP) 64 paths ROUTER-BGP Dell EMC recommends default. OS10(conf-router-bgp-2)# maximum-paths ebgp 2 maxpaths Example (IBGP) OS10(conf-router-bgp-2)# maximum-paths ibgp 4 maxpaths Supported Releases 10.3.0E or later maximum-prefix Configures - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 311
non-deterministic. OS10(conf-router-bgp-10)# non-deterministic-med Supported Releases 10.2.0E or later outbound-optimization Enables outbound optimization for IBGP peer-group members. Syntax outbound-optimization Parameters None Default Not configured Command Mode ROUTER-BGP Layer 3 311 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 312
-optimization Supported Releases 10.3.0E or later password Configures a password for message digest 5 (MD5) authentication on the TCP connection between two neighbors. Syntax Parameters Default Command Mode Usage Information Example password password password-Enter a password for authentication - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 313
(conf-router-bgpv6-af)# redistribute ospf 1 Supported Releases 10.2.0E or later route-reflector-client Configures a neighbor as a member of a route-reflector cluster. Syntax route-reflector-client Parameters None Default Not configured Command Mode ROUTER-TEMPLATE Usage Information The - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 314
in dotted decimal format. First configured IP address or random number ROUTER-BGP Change the router ID of a BGP router to reset peer-sessions. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# router-id 10.10.10.40 Supported Releases 10.3.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 315
0, confed-external Route-reflector origin : 0.0.0.0 Supported Releases 10.3.0E or later show ip bgp dampened-paths Displays BGP routes that are dampened (non-active). Syntax show ip bgp dampened-paths Parameters None Default Not configured Command Mode EXEC Usage Information • Network - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 316
00:12 800 9 8 i Total number of prefixes: 5 Supported Releases 10.3.0E or later show ip bgp flap-statistics Displays BGP flap statistics on BGP routes. Syntax show ip bgp flap-statistics Parameters None Default Not configured Command Mode EXEC Usage Information • Network - Displays the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 317
Default Command Mode Usage Information Example Not configured EXEC This command displays IPv6 BGP routing information. OS10# show ip bgp ipv6 unicast summary BGP router identifier 80.1.1.1 local AS number 102 Neighbor AS MsgRcvd MsgSent Up/Down State/Pfx 80.1.1.2 800 8 4 00:01:10 5 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 318
last read: - Last read is the time (hours:minutes: seconds) the router read a message from its neighbor. - Hold time is the number of seconds configured between messages from its neighbor. - Keepalive interval is the number of seconds between keepalive messages to help ensure that the TCP session is - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 319
Example advertisedroutes OS10# show ip bgp ipv6 unicast neighbors 192:168:1::2 advertised-routes BGP local router ID is 100.1.1.1 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Metric LocPrf Weight - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 320
Up/Down State/Pfx 17.1.1.2 7 7 6 00:01:54 5 Supported Releases 10.2.0E or later show ip bgp summary Displays the status of all BGP connections. Syntax Parameters Default Command Mode Usage Information show ip bgp summary None Not configured EXEC • Neighbor-Displays the BGP neighbor address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 321
inbound Enables soft-reconfiguration for a neighbor. Syntax soft-reconfiguration inbound Parameters None Default Not configured Command Modes ROUTER-BGP-NEIGHBOR-AF Usage Information This command is not supported on a peer-group level. To enable soft-reconfiguration for peers in a peer - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 322
; holdtime 180 seconds ROUTER-BGP The configured timer value becomes effective after a BGP hard reset. The timer values negotiate from peers. The no version of this command resets the value to the default. OS10(conf-router-bgp)# timers 30 90 Supported Releases 10.3.0E or later weight Assigns - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 323
is primarily generated from packet headers to identify micro-flows in traffic. By default, all listed parameters are enabled for load balancing except the ingress port. OS10# show load-balance Load-Balancing Configuration For LAG and ECMP: IPV4 Load Balancing : Enabled IPV6 Load Balancing - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 324
the members. The no version of this command returns the value to the default. Example OS10(config)# hash-algorithm lag crc Supported Releases 10.3.0E or later link-bundle-utilization trigger-threshold Configures a threshold value to trigger monitoring of traffic distribution on an ECMP link - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 325
udp-selection - Enables the TCP UDP port for load-balancing configuration. • ip-selection - Enables IPv4 key parameters to use of this command resets the value to the default. Example (Ingress) OS10(config)# load-balancing ip-selection destination-ip source-ip Supported Releases 10.2.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 326
Default Command Mode Usage Information Example Not configured EXEC None OS10# show hash-algorithm EcmpAlgo - crc LabAlgo - crc Supported Releases 10.3.0E or later IPv4 routing OS10 supports configuration OS10# show interface ethernet 1/1/1 Ethernet 1/1/1 is up, line protocol is up Hardware is Dell - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 327
, 0% of line rate Time since last interface status change: 3 weeks 1 day 20:54:37 Configure static routing You can configure a manual or static route for OSPF. • Configure a static route in CONFIGURATION mode. ip route ip-prefix/mask {next-hop | interface interface [route-preference]} - ip-prefix - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 328
The ARP cache enables dynamically learned addresses to be removed after a configured period. Configure static ARP entries You can manually configure static entries in the ARP mapping table. Dynamic ARP is vulnerable and the traffic flow is affected for all the routes in the switch. 328 Layer 3 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 329
only for the specified route in the switch. Default Command Mode Usage Information Example Not configured EXEC This command does not remove the route 10.1.1.0/24 Supported Releases 10.3.0E or later ip address Configures IP address to an interface. Syntax Parameters Defaults Command Mode - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 330
type and interface information. The interface types supported are: Ethernet, port-channel, VLAN, and Null. • route-preference - (Optional) Enter the range (1 to 255). Default Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command deletes a static - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 331
summary of all ARP entries. Default Command Mode Usage Information Example (IP Address) Not configured EXEC This command shows both static Internet 192.168.1.2 99 00:01:e8:8b:3c:01 Te 1/0 Vl 100 CP Supported Releases 10.2.0E or later show ip route Displays IP route information. Syntax show - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 332
summary - (Optional) Displays an IP route summary. Defaults Command Mode Usage Information Example Not configured EXEC None OS10# show ip route Codes: C setting. If necessary, you can manually disable IPv6 processing on an interface so that the configured IPv6 addresses do not take effect. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 333
:ffff:ffff:ffff. As soon as an IPv6 address is assigned, IPv6 packet processing is enabled on an interface. You can manually disable and re-enable IPv6 processing on an interface configured with an IPv6 address using the no ipv6 enable and ipv6 enable commands. To remove all IPv6 addresses from an - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 334
an OS10 switch boots up, an IPv6 unicast link-local address is automatically assigned to an interface using stateless configuration. A link including the network prefix and a 64-bit interface ID. You can also manually configure an IPv6 address by assigning: • A network prefix with the EUI-64 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 335
(RS). By default, RA response messages are sent when an RS message is received. The system manipulation of IPv6 stateless autoconfiguration supports the router side only. Neighbor Discovery (ND) messages advertise so the neighbor can use the information to auto-configure its address. Received - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 336
it to an interface, an OS10 switch sends a neighbor solicitation message. If the process of duplicate address discovery (DAD) detects a duplicate address in the network, the address is not configured on the interface. DAD is enabled by default. By default, IPv6 is not disabled when a duplicate - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 337
IPv6 routing To define an explicit route between two IPv6 networking devices, configure a static route on an interface. Static routing is useful for 2001:db86:fff::2 ethernet1/1/1 1/1 00:01:24 IPv6 destination unreachable By default, when no matching entry for an IPv6 route is found in the IPv6 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 338
contains options that are processed by all IPv6 routers in the packet's path. By default, hop-by-hop header options in an IPv6 packet are not processed locally. eth1/1/8)# ipv6 hop-by-hop View IPv6 information To view IPv6 configuration information, use the show ipv6 route command. To view IPv6 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 339
table. Traffic flow in the switch is affected only for the specified route. Default Command Mode Usage Information Example Not configured EXEC This command does not conf-if-eth1/1/1)# ipv6 address 2111:dddd:0eee::22/64 Supported Releases 10.3.0E or later ipv6 address autoconfig Acquires global - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 340
)# interface mgmt 1/1/1 OS10(conf-if-ma-1/1/1)# ipv6 address dhcp Supported Releases 10.3.0E or later ipv6 enable Enables and disables IPv6 forwarding on an interface configured with an IPv6 address. Syntax Parameters Defaults Command Mode Usage Information ipv6 enable None None INTERFACE • The - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 341
default, an IPv6 link-local address is automatically generated with a MAC-based EUI-64 interface ID when a router boots up and IPv6 is enabled. Use this command to manually configure -ma-1/1/1)# ipv6 address 2111:dddd:0eee::22/64 link-local Supported Releases 10.4.0E(R1) or later ipv6 hop-by-hop - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 342
Defaults Command Mode Usage Information Duplicate address discovery is enabled on an interface. INTERFACE • An OS10 switch not configured. Other IPv6 addresses are still active on the interface. • By default, DAD ipv6 nd dad disable-ipv6-on-dad-failure Supported Releases 10.4.0E(R1) or later ipv6 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 343
addresses. Syntax Parameters Defaults Command Mode Usage Information Example ipv6 nd managed-config-flag None Not configured INTERFACE The no version default time interval used to send RA messages. OS10(config)# interface ethernet 1/2/3 OS10(conf-if-eth1/2/3)# ipv6 nd max-ra-interval 300 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 344
Parameters Defaults Command Mode Usage Information Example ipv6 nd other-config-flag None Not configured INTERFACE The no version of this command disables the other-config-flag option in RA messages. OS10(config)# interface ethernet 1/2/3 OS10(conf-if-eth1/2/3)# ipv6 nd other-config-flag Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 345
Defaults Command Mode Usage Information All prefixes in IPv6 subnets configured on an interface are advertised. INTERFACE • By default, all prefixes configured 3000::/64 no-autoconfig Supported Releases 10.4.0E(R1) or later ipv6 nd ra-lifetime Sets the lifetime of the default router in RA - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 346
Defaults Command Mode Usage Information Example Not configured INTERFACE The no version of this command disables the configured retransmission timer. OS10(config)# interface ethernet 1/2/3 OS10(conf-if-eth1/2/3)# ipv6 nd retrans-timer 1000 Supported sending RA messages, the switch must be in Router - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 347
/port or number information. The interface types supported are: Ethernet, port-channel, VLAN, and Null. • route-preference - (Optional) Enter a route-preference range (1 to 255). Default Command Mode Usage Information Not configured CONFIGURATION • When the interface fails, the system withdraws - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 348
summary-(Optional) Displays the IPv6 route summary. Default Command Mode Usage Information Example (All) Not configured EXEC None OS10# show ipv6 route all External 0 Ospf Intra-area 0 Total 0 Non-Active Routes 0 0 0 0 0 0 0 0 0 0 0 0 0 Supported Releases 10.2.0E or later 348 Layer 3 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 349
vlan vlan-id - VLAN interface (1 to 4094) Defaults Command Mode Usage Information Example (Brief) None EXEC switches receive multicast frames, they forward them to their intended receivers. OS10 supports IGMP snooping on VLAN interfaces and sends out query packets to VLAN member ports. Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 350
multicast router to a physical port that is a member of the VLAN interface. The multicast router is used for both IGMP and MLD snooping. Configure the member port as multicast router interface, using the ip igmp snooping mrouter interface interface-type command in VLAN INTERFACE mode. IGMP snooping - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 351
IGMP snooping last member query response interval is 1000 ms IGMP snooping fast-leave is disabled on this interface IGMP snooping querier is enabled on this interface --more-- show ip igmp snooping mrouter Interface Router Ports vlan3031 port-channel31 vlan3032 port-channel31 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 352
IGMP and MLD snooping globally. Syntax Parameters Default Command Mode Usage Information Example ip igmp snooping enable None Disabled CONFIGURATION The no version of this command disables the IGMP and MLD snooping. OS10(config)# ip igmp snooping enable Supported Releases 10.4.0E(R1) or later ip - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 353
interface ethernet 1/1/1 Supported Releases 10.4.0E(R1) or later ip igmp snooping querier Enables IGMP and MLD querier processing for the specified VLAN interface. Syntax Parameters Default Command Mode Usage Information Example ip igmp snooping querier None Not configured VLAN INTERFACE The - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 354
10 Interface vlan3031 Member Ports: ethernet1/1/6:1 Mode IGMPv2-Compat Supported Releases 10.4.0E(R1) or later show ip igmp Default Command Mode Usage Information Example show ip igmp snooping interface [vlan vlan-id] vlan-id-(Optional) Enter the VLAN ID, ranging from 1 to 4093. Not configured - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 355
this interface Supported Releases 10.4.0E(R1) or later show ip igmp snooping mrouter Displays the details of multicast router ports. Syntax show ip igmp snooping mrouter [vlan vlan-id] Parameters vlan-id-(Optional) Enter the VLAN ID, ranging from 1 to 4093. Default Not configured Command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 356
snooping mrouter vlan 3031 Interface Router Ports vlan3031 port-channel31 Supported Releases 10.4.0E(R1) or later show ipv6 mld snooping Enter the IPv6 address of the multicast group. Default Command Mode Usage Information Example Not configured EXEC None OS10# show ipv6 mld snooping groups - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 357
ff00:0 and multicast IP MLD Connected Group Membership address) Group Address ff02::1:ff00:0 Interface vlan3031 Member Ports: port-channel31 Mode MLDv1-Compat Supported Releases 10.4.0E(R1) or later Open shortest path first OSPF routing is a link-state routing protocol that allows sending of - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 358
not wholly contained in any area and their attached routers. The backbone is the only area with a default area number. You configure all other areas Area ID. If you configure two nonbackbone areas, you must enable the B bit in OSPF. Routers, A, B, C, G, H, and I are the backbone, see Autonomous - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 359
. Each router has a unique ID, written in decimal format-A.B.C.D. You do not have to associate the router ID with a valid IP address. To make troubleshooting easier, ensure the router ID is identical to the router's IP address. Backbone router A backbone router (BR) is part of the OSPF Backbone - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 360
OSPF routers on the network segment are listening on. The DRs and BDRs are configurable. If you do not define DR or BDR, OS10 assigns them per the BDR, the OSPF looks at the priority of the routers on the segment -default router priority is 1. The router with the highest priority is elected the DR. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 361
Router priority determines the designated router for the network. The default router priority is 1. When two routers are attached to a with 255 as the highest number with the highest priority. OSPF route limit OS10 supports up to 16,000 OSPF routes. Within this range, the only restriction is - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 362
are used. OSPFv2 and OSPFv3 instances support SPF throttling. By default, SPF timers are disabled in an OSPF instance. Enter the no version of this command to remove the configured SPF timers and disable SPF throttling. 1 Configure an OSPF instance from CONFIGURATION mode (1 to 65535). router {ospf - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 363
in this area is 1 SPF algorithm executed 2 times OSPFv2 OSPFv2 supports IPv4 address families. OSPFv2 routers initially exchange hello messages to set by router-identifiers (RID). Enable OSPFv2 OSPFv2 is disabled by default. Configure at least one interface as either physical or LOOPBACK and assign - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 364
managing and troubleshooting purposes, default route to reach external destinations. 1 Enable OSPF routing and enter ROUTER-OSPF mode, from 1 to 65535. router ospf instance number 2 Configure stub area configuration OS10# show ip ospf Routing Process ospf 10 with ID 130.6.196.14 Supports only single - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 365
if-eth1/1/6)# ip ospf passive View passive interfaces OS10# show running-configuration !!! !! interface ethernet1/1/6 ip address 10.10.10.1/24 no Select the higher convergence levels only after checking with Dell Technical Support. When you disable fast-convergence, origination and arrival LSA - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 366
Configure fast convergence OS10(config)# router ospf 65535 OS10(conf-router-ospf-65535)# fast-converge 1 View fast convergence OS10(conf-router-ospf-65535)# do show ip ospf Routing Process ospf 65535 with ID 99.99.99.99 Supports dead in INTERFACE mode. The default time interval is 40. The dead - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 367
route You can generate an external default route and distribute the default information to the OSPFv2 routing domain. • To generate the default route, use the default-information originate [always] command in ROUTER-OSPF mode. Configure default route OS10(config)# router ospf 10 OS10(config-router - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 368
ospf-10)# show configuration ! router ospf 10 default-information originate always Summary address You can configure a summary address helper mode and sends an acknowledgement back to the restarting device. OS10 supports graceful restart helper mode. Use the graceful-restart role helper-only command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 369
the OSPF database? • Are you able to ping the IPv4 address of adjacent router interface? Troubleshooting OSPF with show commands • View a summary of all OSPF process IDs enabled in EXEC mode. show running-configuration ospf • View summary information of IP routes in EXEC mode. show ip route summary - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 370
command resets the value to the default. OS10(conf-router-ospf-10)# area 10.10.1.5 default-cost 10 Supported Releases 10.2.0E or later area that no summary LSAs are sent into the NSSA. Default Command Mode Usage Information Example Not configured ROUTER-OSPF The no version of this command deletes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 371
)# router ospf 10 OS10(conf-router-ospf-10)# area 10.10.1.5 stub Supported Releases 10.2.0E or later auto-cost reference-bandwidth Calculates default metrics for the interface based on the configured auto-cost reference bandwidth value. Syntax auto-cost reference-bandwidth value Parameters - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 372
in a specified instance or in all the configured OSPF instances, and resets them to zero. Example OS10# clear ip ospf 10 statistics Supported Releases 10.4.0E(R1) or later default-information originate Generates and distributes a default external route information to the OSPF routing domain - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 373
Command Mode Usage Information Example number - Enter a default-metric value (1 to 16777214). Not configured ROUTER-OSPF The no version of this command disables the default-metric configuration. OS10(conf-router-ospf-10)# default-metric 2000 Supported Releases 10.2.0E or later fast-converge Sets - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 374
an OSPF area. OS10(conf-if-vl-10)# ip ospf 10 area 5 Supported Releases 10.2.0E or later ip ospf authentication-key Configures a text authentication key to enable OSPF traffic on an interface. Syntax Parameters Defaults Command Mode Usage Information Example ip ospf authentication-key key key - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 375
Enter a character string as the password (up to 16 characters). Defaults Command Mode Usage Information Example Not configured INTERFACE All neighboring routers in the same if-eth1/1/1)# ip ospf message-digest-key 2 md5 sample12345 Supported Releases 10.3.0E or later ip ospf mtu-ignore Enables - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 376
Broadcast INTERFACE The no version of this command resets the value to the default. OS10(conf-if-eth1/1/1)# ip ospf network broadcast Supported Releases 10.2.0E or later ip ospf passive Configures an interface as a passive interface and suppresses routing updates (both receiving and sending - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 377
one with the higher router priority takes precedence. The no version of this command resets the value to the default. OS10(conf-if-eth1/1/6)# ip ospf priority 4 Supported Releases 10.2.0E or later ip ospf retransmit-interval Sets the retransmission time between lost LSAs for adjacencies belonging - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 378
from other routers. Syntax max-metric router-lsa Parameters None Default Not configured Command Mode ROUTER-OSPF Usage Information Routers in the network do the value to the default. OS10(config)# router ospf 10 OS10(conf-router-ospf-10)# maximum-paths 1 Supported Releases 10.2.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 379
config)# router ospf 10 OS10(conf-router-ospf-10)# redistribute connected route-map dell2 Supported Releases 10.2.0E or later router-id Configures a fixed router ID for the OSPF process. Syntax Parameters Default Command Mode Usage Information Example router-id ip-address ip-address - Enter the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 380
based on the process ID. Default Not configured Command Mode EXEC Usage Information You can isolate problems with external routes. External OSPF 1 0 Nexthop 110.1.1.2 0.0.0.0 Interface vlan3050 - Area 0.0.0.0 - Supported Releases 10.2.0E or later show ip ospf database Displays all LSA - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 381
0x80000008 0x80000008 0x80000008 0x80000008 Summary Network (Area 0.0.0.0) Supported Releases 10.2.0E or later Checksum 0x9bf2 0x515a enter a process ID, this applies only to the first OSPF process. Default Not configured Command Mode EXEC Usage Information • LS Age-Displays the LS age. • - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 382
Network Mask: /0 TOS: 0 Metric: 0 Supported Releases 10.2.0E or later show ip ospf database (Type 5) LSAs. Syntax Parameters Default Command Mode Usage Information show ip ID, this command applies only to the first OSPF process. Not configured EXEC • LS Age - Displays the LS age. • Options - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 383
Process ID, this command applies only to the first OSPF process. Default Not configured Command Mode EXEC Usage Information • LS Age-Displays the LS age. Mask: /24 Attached Router: 111.2.1.1 Attached Router: 112.2.1.1 Supported Releases 10.2.0E or later show ip ospf database nssa external - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 384
Parameters Default Command Mode Usage Information process-id - (Optional) Displays NSSA-External (Type7) LSA information for a specified OSPF Process ID. If you do not enter a Process ID, this command applies only to the first OSPF process. Not configured EXEC • LS Age - Displays the LS age. • - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 385
: 0 Metric: 20 Forward Address: 0.0.0.0 External Route Tag: 0 Supported Releases 10.2.0E or later show ip ospf database opaque-area Displays information ID, this command applies only to the first OSPF process. Default Not configured Command Mode EXEC Usage Information • LS Age - Displays the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 386
0x83B8 Length: 28 Opaque Type: 8 Opaque ID: 65794 !! ! Supported Releases 10.2.0E or later show ip ospf database opaque-as Displays Process ID, this command applies only to the first OSPF process. Default Not configured Command Mode EXEC Usage Information • LS Age - Displays the LS - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 387
Process ID, this command applies only to the first OSPF process. Default Not configured Command Mode EXEC Usage Information • LS Age - Displays the LS Checksum: 0x9DA1 Length: 28 Opaque Type: 8 Opaque ID: 65793 Supported Releases 10.2.0E or later show ip ospf database router Displays - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 388
Transit Network (Link ID) Designated Router address: 111.2.1.1 (Link Data) Router Interface address: 111.2.1.1 Number of TOS metric: 0 TOS 0 Metric: 1 Supported Releases 10.2.0E or later show ip ospf database summary Displays the network summary (Type 3) LSA routing information. Syntax show ip - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 389
/24 TOS: 0 Metric: 0 Supported Releases 10.2.0E or later show ip ospf interface Displays the configured OSPF interfaces. You must enable OSPF - vlan - Enter the VLAN interface number (1 to ). Default Command Mode Example Not configured EXEC OS10# show ip ospf interface ethernet1/1/1 is up, line - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 390
configured, Hello 10, Dead 40, Wait 40, Retransmit 5 Simple password authentication enabled Neighbor Count is 0, Adjacent neighbor count is 0 Supported an IP address to view information specific to the IP address. Default Command Mode Usage Information Example None EXEC Displays the cost metric for - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 391
Displays routers which are directly connected to OSPF areas. Syntax Parameters Default Command Mode Usage Information Example show ip ospf [process-id] 3050 Vl 3050 Area 0 0 0 0 0 Supported Releases 10.2.0E or later summary-address Configures a summary address for an ASBR to advertise one - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 392
ospf 100 OS10(config-router-ospf-100)# summary-address 10.0.0.0/8 not-advertise Supported Releases 10.3.0E or later timers lsa arrival Configures the LSA acceptance intervals. Syntax Parameters Default Command Mode Usage Information Example timers lsa arrival arrival-time arrival-time - Set - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 393
is 1 SPF algorithm executed 1 times Supported Releases 10.4.0E(R1) or later timers throttle lsa all Configures the LSA transmit intervals. Syntax timers waits before sending the LSA in milliseconds (1 to 600,000). . Default • start-interval - 0 milliseconds • hold-interval - 5000 milliseconds - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 394
OSPFv3 OSPFv3 is an IPv6 link-state routing protocol that supports IPv6 unicast address families (AFs). OSPFv3 is disabled by default. You must configure at least one interface, either physical or loopback. The OSPF process automatically starts when OSPFv3 is enabled for one or more interfaces. Any - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 395
SPF algorithm executed 42 times Area (0.0.0.1) Number of interface in this area is 1 SPF algorithm executed 42 times Configure Stub Areas The Type 5 LSAs are not flooded into stub areas. The ABR advertises a default route into the stub area to which it is attached. Stub area routers use the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 396
of OSPF neighbors. 1 Enter the interface to change the OSPFv3 parameters in CONFIGURATION mode. interface interface-name 2 Change the cost associated with OSPFv3 traffic on the interface in INTERFACE mode, from 1 to 65535, default depends on the interface speed. ipv6 ospf cost 3 Change the time - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 397
default-information originate always View default route configuration OS10(config-router-ospf-100)# show configuration ! router ospfv3 100 default of 51. MD5 and SHA1 authentication types are supported; encrypted and unencrypted keys are supported. • ESP encryption encapsulates data, enabling the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 398
key must be 40 hex digits. An encrypted key is not supported. To delete an IPsec authentication policy, use the no ipv6 ospf authentication ipsec spi number or no ipv6 ospf authentication null command. Configure IPsec authentication on interface OS10(conf-if-eth1/1/1)# ipv6 ospf authentication - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 399
non-encrypted key must be 40 hex digits. An encrypted key is not supported. To delete an IPsec encryption policy, use the no ipv6 ospf encryption ipsec spi number or no ipv6 ospf encryption null command. Configure IPsec encryption on interface OS10(conf-if-eth1/1/1)# ipv6 ospf encryption ipsec spi - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 400
must share the key to decrypt information. Only a non-encrypted key is supported. Required lengths of the non-encrypted key are: 3DES - 48 hex digits interface? Troubleshooting OSPFv3 with show Commands • View a summary of all OSPF process IDs enabled in EXEC mode. show running-configuration ospfv3 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 401
or NULL). For AES-CBC, only the AES-128 and AES-192 ciphers are supported. • key - Enter the text string used in the encryption algorithm. • used in the authentication algorithm. Default Command Mode Usage Information OSPFv3 area encryption is not configured. ROUTER-OSPFv3 • Before you enable - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 402
)# router ospfv3 10 OS10(conf-router-ospfv3-10)# area 10.10.1.5 stub Supported Releases 10.3.0E or later auto-cost reference-bandwidth Calculates default metrics for the interface based on the configured auto-cost reference bandwidth value. Syntax auto-cost reference-bandwidth value Parameters - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 403
{instance-number} process Parameters instance-number - Enter an OSPFv3 instance number (1 to 65535). Default Not configured Command Mode EXEC Usage Information None Example OS10# clear ipv6 ospf 3 process Supported Releases 10.3.0E or later clear ipv6 ospf statistics Clears OSPFv3 traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 404
or enter an area ID number (1 to 65535). Default Command Mode Usage Information Example Not configured INTERFACE The no version of this command removes an share the key to exchange information. Only a non-encrypted key is supported. For MD5 authentication, the non-encrypted key must be 32 plain - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 405
The dead interval is four times the default hello-interval by default. The no version of this command removes the IPv6 OSPF dead-interval configuration. Example OS10(config)# interface vlan 10 OS10(conf-if-vl-10)# ipv6 ospf dead-interval 10 Supported Releases 10.3.0E or later ipv6 ospf - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 406
configure encryption if you have already configured an interface for IPsec authentication (ipv6 ospf authentication ipsec). To configure command resets the value to the default. OS10(config)# interface vlan 10 OS10(conf-if-vl-10)# ipv6 ospf hello-interval 30 Supported Releases 10.3.0E or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 407
ospf passive Parameters None Default Not configured Command Mode INTERFACE Usage Information You must configure the interface before setting Passive interface configuration. Example OS10(config)# interface ethernet 1/1/6 OS10(conf-if-eth1/1/6)# ipv6 ospf passive Supported Releases 10.3.0E - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 408
100)# redistribute connected route-map dell2 Supported Releases 10.3.0E or later router-id Configures a fixed router ID for the OSPFv3 of the router as the router ID. Default Not configured Command Mode ROUTER-OSPFv3 Usage Information Configure an arbitrary value in the IP address format - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 409
command deletes an OSPFv3 instance. Example OS10(config)# router ospfv3 10 Supported Releases 10.3.0E or later show ipv6 ospf Displays OSPFv3 instance configuration information. Syntax Parameters Default Command Mode Usage Information Example show ipv6 ospf [instance-number] instance-number - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 410
not enter a process ID, the command applies to all the configured OSPFv3 processes. Default Not configured Command Mode EXEC Usage Information • Link ID-Identifies the router ID 3116 0x80000126 400::/64 3.3.3.3 3116 0x80000124 34::/64 Supported Releases 10.3.0E or later 410 Layer 3 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 411
is 1 Adjacent with neighbor 2.2.2.2(Designated Router) Supported Releases 10.3.0E or later show ipv6 ospf neighbor Displays a list of OSPFv3 neighbors connected to the local router. Syntax show ipv6 ospf neighbor Parameters None Default Not configured Command Mode EXEC Usage Information - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 412
the VLAN ID number (1 to 4094). Default Command Mode Usage Information Example Not configured EXEC This command displays OSPFv3 traffic statistics 0 self-orig 0 wrong-length 0 version-mismatch 0 area-mismatch 0 Supported Releases 10.4.0E(R1) or later timers spf (OSPFv3) Enables shortest path - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 413
or max-wait value, the default values are used. The no version of this command removes the configured SPF timers and disables SPF throttling Number of interface in this area is 1 SPF algorithm executed 2 times Supported Releases 10.4.0E(R1) or later Object tracking manager Object tracking manager - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 414
You can create an object that tracks the line-protocol state of a Layer 2 interface, and monitors its operational status (Up or Down). You can configure up to 500 objects. Each object is assigned a unique ID. The no version of this command deletes the tracked object from an interface. When the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 415
status of a tracked interface in OBJECT TRACKING mode from 0 to 80 seconds; default 0. delay [up seconds] [down seconds] 4 (Optional) View the tracked is UP 1 changes, Last change 2017-04-26T06:41:36Z Host tracking If you configure an IP host as a tracked object, the entry or the next-hop address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 416
is canceled. The client is not notified of the event. If you do not configure a delay, a notification is sent when a change in the state of a tracked , VRRP can track up to 20 interface objects plus 12 tracked interfaces supported for each VRRP group. You can assign a unique priority-cost value - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 417
the delay time in seconds (up to 180). Defaults Not configured Command Mode CONFIGURATION Usage Information None Example OS10(conf-track-100)# delay up 200 down 100 Supported Releases 10.3.0E or later interface line-protocol Configures an object to track a specific interface's line-protocol - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 418
ip-address reachability Parameters host-ip-address - Enter the IPv6 host address. Defaults Not configured Command Mode CONFIGURATION Usage Information None Example OS10(config)# track 200 OS10(conf-track-200)# ipv6 10::1 reachability Supported Releases 10.3.0E or later reachability-refresh - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 419
reachablity 10::10 DOWN 2017-02-03T08:41:55Z1 Supported Releases 10.3.0E or later track Configures and manages tracked objects. Syntax track object-id object ID to track (up to 500). Defaults Not configured Command Mode CONFIGURATION Usage Information The no version of this command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 420
, as where deny in the route-map statement indicates a switch-based forwarding decision-PBR exception. Access-list is used only for the packet match criteria in policy-based routing. 1 Assign an access-list to match the route-map in CONFIGURATION mode. ip access-list access-list-name 2 Set the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 421
to an IPv6 interface OS10(conf-if-eth1/1/5)# ipv6 policy route-map map2 View PBR information Display PBR information to verify IPv4 or IPv6 configuration and view statistics. 1 View IPv4 or IPv6 PBR policy information in EXEC mode. show {ip | ipv6} policy name 2 View the current PBR statistics in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 422
map-name-Enter the name of a configured route-map (up to 140 characters). Defaults Not configured Command Mode INTERFACE Usage Information None Example OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# ip policy route-map map1 Supported Releases 10.3.0E or later 422 Layer - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 423
} next-hop address Parameters address - Enter the next-hop IPv4 or IPv6 address. Defaults Not configured Command Mode ROUTE-MAP Usage Information None Example OS10(conf-route-map)# set ip next-hop 10.10.10.10 Supported Releases 10.3.0E or later set next-hop track Sets the next-hop IPv4 or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 424
same router at the same time. OS 10 supports a management VRF instance and a default VRF instance. You can add management ports to the management VRF instance. All the front panel ports and logical interfaces are part of the default VRF instance. Configure management VRF You can add only management - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 425
Configure management VRF OS10(config)# ip vrf management OS10(conf-vrf)# interface management You can enable various services in the either of the management or default VRF instances. Refer to the following table for the services supported in the management VRF instance and the default VRF instance. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 426
domain-name-Enter the domain name. Default Not configured Command Mode CONFIGURATION Usage Information The no version of this command removes the host name from the management VRF instance. Example OS10(config)# ip domain-name vrf management dell.com Supported Releases 10.4.0E(R1) or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 427
address-Enter the host IP/IPv6 address. Default Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes the host name from the management VRF instance. OS10(config)# ip host vrf management dell 10.1.1.1 Supported Releases 10.4.0E(R1) or later ip - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 428
(config)# ip name-server vrf management Supported Releases 10.4.0E(R1) or later ip scp vrf Configures a SCP connection for the management VRF instance. Syntax ip scp vrf management Parameters None Default Not configured Command Mode CONFIGURATION Usage Information The no version of this - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 429
client. OS10(config)# ip tftp vrf management Supported Releases 10.4.0E(R1) or later ip vrf management Configures the management VRF instance. Syntax ip vrf management Parameters None Default Not configured Command Mode CONFIGURATION Usage Information Enter the ip vrf management command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 430
google.com 172.217.160.142 yahoo.com 98.139.180.180 Supported Releases 10.4.0E(R1) or later show ip vrf Displays the VRF instance information. Syntax show ip vrf [management] Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# show ip vrf VRF- - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 431
network configuration using VRRP. Instead of configuring the hosts on network 10.10.10.0 with the IP address of either Router A or Router B as the default router, the default router VRRP allows Router B to provide uninterrupted service to the users on the LAN segment accessing the Internet. Layer - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 432
config)# vrrp version 3 Use the vrrp version both command in Configuration mode to migrate from VRRPv2 to VRRPv3. When you set the VRRP version to vrrp version both, the switch sends and receives both VRRPv2 or VRRPv3 packets. 1 Set the switch with the lowest priority to vrrp version both. 2 Set the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 433
switches to VRRPv3 OS10_backup_switch1(config)# vrrp version 3 OS10_backup_switch2(config)# vrrp version 3 Virtual IP addresses Virtual routers contain virtual IP addresses configured configured on the interface, Dell EMC recommends configuring is set to 255 by default. The interface then becomes the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 434
for the interface with the VRRP identifier in INTERFACE mode (1 to 255). vrrp-group vrrp-id 2 Configure the priority number for the VRRP group in INTERFACE-VRRP mode (1 to 255, default 100). priority number Set VRRP group priority OS10(config)# interface ethernet 1/1/5 OS10(conf-if-eth1/1/5)# vrrp - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 435
or authentication is disabled. Authentication for VRRPv3 is not supported. 1 Create a virtual router for the interface with the VRRP identifier in INTERFACE mode (1 to 255). vrrp-group vrrp-id 2 Configure a simple text password in INTERFACE-VRRP mode. authentication-type simple-text text [auth - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 436
configuration change at Sep 24 07:17:45 2016 ! debug radius false snmp-server contact http://www.dell.com/support/softwarecontacts snmp-server location "United States" username admin password 1.1.1.3 no preempt ! Advertisement interval By default, the Master router transmits a VRRP advertisement - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 437
interface according to the virtual group. OS10 supports a maximum of 10 track groups and each goes down, the VRRP group's priority decreases by a default value of 10 - also known as cost. If object is defined and determined to be down. Configure tracking To track the objects in a VRRP group or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 438
interface vlan1 no shutdown ! interface mgmt1/1/1 no shutdown ! support-assist ! track 10 track-interface ethernet1/1/1 VRRP commands 25 (25 to 4075). Default Command Mode Usage Information 1 second or 100 centisecs INTERFACE-VRRP Dell EMC recommends keeping the default setting for this command. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 439
Supported Releases 10.2.0E or later authentication-type Enables authentication of VRRP data exchanges. Syntax authentication-type simple-text password [auth-text] Parameters • simple-text password - Enter a simple text password With preempt enabled by default, VRRP switches to a backup if that - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 440
status information (1 to 255). Default Command Mode Usage Information Example (Brief) All IPv4 VRRP group configuration EXEC Displays all active VRRP pkts-rcvd : 0 address-list-errors : 0 pkt-length-errors : 0 Supported Releases 10.2.0E or later track Assigns a unique identifier to track an - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 441
operational status information. The no version of this command resets the value to the default. OS10(config)# track 10 OS10(conf-track-10)# interface ethernet 1/1/5 Supported Releases 10.2.0E or later virtual-address Configures up to 10 virtual router IP addresses in the VRRP group. Set at least - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 442
reload time of zero seconds indicates no delays. This command configuration applies to all the VRRP configured interfaces. The no version of this command resets the value to the default. Example OS10(config)# vrrp delay reload 5 Supported Releases 10.4.0E(R1) or later vrrp-group Assigns a VRRP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 443
removes the vrrp-ipv6-group configuration. OS10(conf-if-eth1/1/7)# vrrp-ipv6-group 250 Supported Releases 10.2.0E or later vrrp in-service migration from VRRP version 2 to VRRP version 3. • 3 - Set to VRRP version 3. Default Command Mode Usage Information Example Not configured CONFIGURATION - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 444
Size for S41XX UFT Mode L2 MAC Table Size Scaled-l2-switch 278528 Scaled-l3-hosts 16384 Scaled-l3-routes 16384 Default 81920 L3 Host Table Size 4096 266240 4096 69632 L3 Routes Table Size 16384 16384 262144 131072 Configure UFT modes Available UFT modes include L2 MAC table, L3 host - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 445
-hosts - Maximize the L3 hosts table size Defaults Command Mode Usage Information Example The default parameters vary according to the platform. See UFT modes. CONFIGURATION Configure the sizes of internal L2 and L3 forwarding tables of the switch as per the requirements of the network environment - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 446
: 16384 Next-boot Settings scaled-l3-hosts 98304 212992 98304 Supported Releases 10.3.0E or later show hardware forwarding-table mode all forwarding-table modes. OS10# show hardware forwarding-table mode all Mode default scaled-l2 scaled-l3-routes L2 MAC Entries 163840 294912 32768 L3 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 447
The DHCP server listens on port 67 and transmits to port 68. The DHCP client listens on port 68 and transmits to port 67. The configuration parameters are options in the DHCP packet in type, length, value (TLV) format. To limit the number of parameters that servers must provide, hosts enter - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 448
Protocol (DHCP) server provides network configuration parameters to DHCP clients on request. A DHCP server dynamically allocates four required IP parameters to each computer on the virtual local area network (VLAN) - the IP address, network mask, default gateway, and name server address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 449
(config)# ip dhcp server OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# network 20.1.1.0/24 Show running configuration OS10(conf-dhcp-Dell)# do show running-configuration ... ! ip dhcp server ! pool Dell lease 24 network 20.1.1.0/24 default-router 20.1.1.1 Address lease time Use the lease {days - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 450
ip dhcp server OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# default-router 20.1.1.1 Enable DHCP server Use the ip dhcp server command to enable DHCP server-assigned dynamic addresses on an interface in CONFIGURATION mode. The DHCP server is disabled by default. OS10(config)# ip dhcp server OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 451
Configure NetBIOS WINS address resolution OS10(config)# ip dhcp server OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# netbios-name-server 192.168.10.5 OS10(conf-dhcp-Dell)# netbios-node-type Hybrid Manual binding entries Address binding is mapping between the IP address and the media access - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 452
is supported, but not configurable. configuration ! Version 10.2.9999E ! Last configuration change at Feb 20 04:50:33 2017 ! username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/VKx8SloIhp4NoGZs0I/ UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication system:local ip domain-name dell - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 453
. Use the no version of this command to remove the configuration. OS10(conf-dhcp-20.1.1.1)# default-router 20.1.1.100 Supported Releases 10.2.0E or later disable Disables the DHCP server. Syntax Parameters Default Command Mode Usage Information Example disable None Disabled DHCP The no - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 454
dhcp-Dell)# domain-name dell.com Supported Releases 10.2.0E or later hardware-address Configures the client hardware address for manual configurations. Syntax hardware-address nn:nn:nn:nn:nn:nn Parameters nn:nn:nn:nn:nn:nn - Enter the 48-bit hardware address. Default Not configured Command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 455
used by the client machine for DHCP. OS10(conf-dhcp-Dell)# host 20.1.1.100 Supported Releases 10.2.0E or later ip dhcp server Enters DHCP mode. Syntax ip dhcp server Parameters None Default Not configured Command Mode CONFIGURATION Usage Information This command is used to enter DHCP mode - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 456
order of preference. The no version of this command returns the value to the default. OS10(conf-dhcp-Dell)# netbios-name-server 192.168.10.5 Supported Releases 10.2.0E or later netbios-node-type Configures the NetBIOS node type for the DHCP client. Syntax Parameters netbios-node-type type type - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 457
Parameters pool-name - Enter the DHCP server pool name. Default Not configured Command Mode CONFIGURATION Usage Information Use this command to create an IP address pool name. Example OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# Supported Releases 10.2.0E or later show ip dhcp binding - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 458
of this command removes a domain name from the DNS list. OS10(config)# ip domain-list jay dell.com Supported Releases 10.2.0E or later ip domain-name Configures the default domain and appends to incomplete DNS requests. Syntax ip domain-name server-name Parameters server-name - (Optional - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 459
or A::B format. Default Command Mode Usage Information Example Not configured CONFIGURATION The name-to-IP address table uses this mapping information to resolve host names. The no version of this command disables the mapping. OS10(config)# ip host dell 1.1.1.1 Supported Releases 10.2.0E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 460
Host IP-Address dell-pc1 20.1.1.1 Supported Releases 10.2.0E or later Network time protocol NTP : OS10 supports both NTP server and client roles. Enable NTP NTP is disabled by default. To enable NTP, configure an NTP server to which the system synchronizes. To configure multiple servers - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 461
The source address of NTP packets is the interface IP address the system uses to reach the network by default. • Configure a source IP address for NTP packets in CONFIGURATION mode. ntp source interface - ethernet - Enter the keyword and node/slot/port information. - port-channel - Enter the keyword - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 462
IPv6 address in nnnn:nnnn:nnnn:nnnn:nnnn:nnnn:nnnn:nnnn format (elision of zeros is supported). • key keyid - Enter a text string as the key exchanged between the NTP the NTP server hierarchy in CONFIGURATION mode (2 to 10, default 8). ntp master Configure NTP OS10(config)# ntp authenticate - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 463
Default Command Mode Usage Information Example 0 CONFIGURATION The authentication number must be the same as the number parameter configured in the ntp trusted-key command. Use the ntp authenticate command to enable NTP authentication. OS10(config)# ntp authentication-key 1200 md5 0 dell Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 464
. OS10(conf-if-eth1/1/7)# ntp disable Supported Releases 10.2.0E or later ntp enable vrf management Enables NTP for the management VRF instance. Syntax Parameters Defaults Command Mode Usage Information Example ntp enable vrf management None Disabled CONFIGURATION The no version of this command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 465
Usage Information Example The no version of this command resets the value to the default. OS10(config)# ntp master 6 Supported Releases 10.2.0E or later ntp server Configures an NTP time-serving host. Syntax Parameters ntp server {hostname | ipv4-address | ipv6-address} [key keyid] [prefer] • - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 466
the key. OS10(config)# ntp trusted-key 234567 Supported Releases 10.2.0E or later show ntp associations Displays the NTP master and peers. Syntax Parameters Default Command Mode Usage Information show ntp associations [vrf management] None Not configured EXEC • (none) - One or more of the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 467
local st poll reach delay offset disp *1.1.1.2 1.1.1.1 3 64 1 0.00027 0.000056 0.43309 Supported Releases 10.2.0E or later show ntp status Displays NTP configuration information. Syntax Parameters Default Command Mode Usage Information Example (Status) show ntp status [vrf management - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 468
, where YYYY is a four-digit year, such as 2016; MM is a month from 1 to 12; DD is a day from 1 to 31. • Enter the timezone in CONFIGURATION mode. clock timezone timezone-string Hours Minutes Enter timezone-string which is the name of the time zone. Enter Hours offset from UTC, ranging from - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 469
your time zone. OS10(config)# clock timezone IST 5 30 Supported Releases 10.3.0E or later show clock Displays the current system clock settings. Syntax Parameters Default Command Mode Usage Information Example show clock None Not configured EXEC The universal time coordinated (UTC) value is the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 470
value in seconds (0 to 3600). Default Not configured Command Mode CONFIGURATION Usage Information The no version of this command disables the timeout. Example OS10(config)# exec-timeout 300 OS10(config)# Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 471
Usage Information Example session-ID - Enter the user session ID. Not configured EXEC None OS10# kill-session 3 Supported Releases 10.3.1E or later show sessions Displays the active management sessions. Syntax Parameters Default Command Mode Usage Information Example show sessions None Not - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 472
an OS10 switch. Syntax Parameters Default Command Mode Usage Information Example ip telnet server enable None Disabled CONFIGURATION By default, the Telnet services secure networks against unauthorized access. In addition to local authentication, OS10 supports remote authentication dial-in service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 473
of the switch and all OS10 sessions are terminated. By default, user re-authentication is disabled. Enable user re-authentication • Enable user re-authentication in CONFIGURATION mode. aaa re-authenticate enable Enter the no form of the command to disable user re-authentication. Password strength By - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 474
default 0). Create password rules OS10(config)# password-attributes min-length 7 character-restriction upper 4 numeric 2 Display password rules OS10(config)# do show running-configuration password-attributes password enable password because you are automatically placed in EXEC mode. OS10 supports the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 475
the OS10 switch on the server. • Configure a RADIUS authentication server in CONFIGURATION mode. By default, a RADIUS server uses UDP port 1812; the switch uses radius_server . By default, OS10 supports three RADIUS authentication attempts and times out after five seconds. • Configure the number - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 476
security by encrypting the entire protocol portion in a packet sent from the switch to an authentication server. RADIUS encrypts only passwords. • Configure a TACACS+ authentication server in CONFIGURATION mode. By default, a TACACS+ server uses TCP port 49 for authentication. tacacs-server host - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 477
-auth-tries is reduced by one. In this case, if you configured ip ssh server max-auth-tries 1, the password prompt does not display. Virtual terminal line Virtual terminal line (VTY) is used to control Telnet or SSH connections to the switch. You can enter the VTY mode by using the line vty - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 478
host command. Default Command Mode Usage Information Example Local authentication CONFIGURATION There is no no version of this command. To reset the authentication method to local, enter the aaa authentication local command. OS10(config)# aaa authentication radius Supported Releases 10.2.0E - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 479
challenge-response-authentication Parameters None Default Disabled Command Mode CONFIGURATION Usage Information The no version of this command disables the challenge response authentication. Example OS10(config)# ip ssh server challenge-response-authentication Supported Releases 10.3.0E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 480
OS10(config)# ip ssh server cipher 3des-cbc aes128-cbc Supported Releases 10.3.0E or later ip ssh server enable Enable the SSH server. Syntax Parameters Default Command Mode Usage Information Example ip ssh server enable None Enabled CONFIGURATION The no version of this command disables the SSH - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 481
SSH server. Syntax Parameters Default Command Mode Usage Information Example ip ssh server hostbased-authentication None Disabled CONFIGURATION The no version of this command disables the host-based authentication. OS10(config)# ip ssh server hostbased-authentication Supported Releases 10.3.0E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 482
[email protected] • [email protected] • [email protected] Default • hmac-sha1 • hmac-sha2-256 • hmac-sha2-512 • [email protected] CONFIGURATION The no version of this command removes the configuration. OS10(config)# ip ssh server mac hmac-md5 hmac-md5-96 hmac-ripemd160 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 483
an SSH server. Syntax Parameters Default Command Mode Usage Information Example ip ssh server password-authentication None Enabled CONFIGURATION The no version of this command disables the password authentication. OS10(config)# ip ssh server password-authentication Supported Releases 10.3.0E or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 484
terminal line mode to access the virtual terminal (VTY). Syntax Parameters Default Command Mode Usage Information Example line vty None Not configured CONFIGURATION None OS10(config)# line vty OS10(config-line-vty)# Supported Releases 10.4.0E(R1) or later login-statistics enable Enables the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 485
: 0 • Special characters: 0 Command Mode Usage Information EXEC • By default, the password you configure with the username password command must be at least nine alphanumeric characters. • Use the password-attributes command to increase password strength. When you enter the command, at least one - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 486
retransmit 50 Supported Releases 10.2.0E or later radius-server timeout Configures the timeout used to resend RADIUS authentication requests. Syntax radius-server timeout seconds Parameters seconds - Enter the time in seconds for retransmission (0 to 1000). Default An OS10 switch stops - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 487
from the management VRF instance. OS10(config)# radius-server vrf management Supported Releases 10.4.0E(R1) or later show ip ssh Displays the SSH server information. Syntax show ip ssh Parameters None Default Not configured Command Mode EXEC Usage Information Use this command to view - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 488
:42:07Z Last Login Location : 1001:10:16:210::4001 Supported Releases 10.4.0E(R1) or later show users Displays information for all users logged into OS10. Syntax Parameters Default Command Mode Usage Information show users None Not configured EXEC Use this command to view current OS10 users - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 489
response from a TACACS+ server (1 to 1000 seconds). Default 5 seconds Command Mode CONFIGURATION Usage Information The no version of this command resets the TACACS+ server timeout to the default. Example OS10(config)# tacacs-server timeout 360 Supported Releases 10.4.0E(R2) or later System - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 490
configuration. A network operator cannot modify any configuration setting on a switch. Default • User name and password entries are in clear text. • There is no default user role. Command Mode Usage Information CONFIGURATION • By default, the password bases (MIBs) are supported, including all get - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 491
ro Supported Releases 10.2.0E or later snmp-server contact Configures contact information for troubleshooting this SNMP node. Syntax snmp-server contact text Parameters text - Enter an alphanumeric text string (up to 55 characters). Default Not configured Command Mode CONFIGURATION Usage - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 492
Default Command Mode Usage Information Example snmp-server location text text - Enter an alphanumeric string (up to 55 characters). United States CONFIGURATION The no version of this command removes the SNMP location. OS10(config)# snmp-server location datacenter10 Supported to the switch is still - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 493
uplink failure detection Consider the following before configuring an uplink-state group: • You can assign a physical port -state group, the downstream interfaces are not disabled. Configuration: 1 Create an uplink-state group in CONFIGURATION mode. uplink-state-group group-id System management 493 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 494
the UFD error disabled state of downstream interfaces in EXEC mode. clear ufd-disable Configure uplink state group OS10(config)# uplink-state-group 1 OS10(conf-uplink-state-group-1)# group-id - Enter the uplink state group ID, from 1 to 32. Default Command Mode None EXEC 494 System management - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 495
manually Default Disabled Command Mode UPLINK-STATE-GROUP Usage Information The no version of this command disables tracking of an uplink-state group. Example OS10(config)# uplink-state-group 1 OS10(conf-uplink-state-group-1)# enable Supported Releases 10.4.0E(R3) or later name Configures - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 496
upstream fibrechannel1/1/1 Supported Releases 10.4.0E(R3) or later show uplink-state-group Displays configured uplink-state status information on the status of the uplink-state groups. Default Command Mode Usage Information Example Not configured EXEC None OS10# show uplink-state-group Uplink - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 497
a unique ID for the uplink-state group, from 1 to 32. Default None Command Mode CONFIGURATION Usage Information The no version of this command removes the uplink-state group. Example OS10(config)# uplink-state-group 1 Supported Releases 10.4.0E(R3) or later upstream Adds an interface or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 498
the current running configuration to the startup configuration in EXEC mode. copy running-configuration startup-configuration 2 Backup the startup configuration in EXEC mode. copy config://startup.xml config:// 3 Download the new software image from dell.com/support, extract the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 499
as the next boot partition. Default Command Mode Usage Information Example Active EXEC Use this command to configure the location of the OS10 image configured next boot image. This command is applied immediately and does not require the commit command. OS10# boot system standby Supported Releases - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 500
image cancel Cancels an active image download. Syntax Parameters Default Command Mode Usage Information Example image cancel None Not configured EXEC This command attempts to cancel an active file download in progress. OS10# image cancel Supported Releases 10.2.0E or later image copy Copies - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 501
-Enterprise-10.4.0E.55installer-x86_64.bin Supported Releases 10.2.0E or later show boot Displays boot partition-related information. Syntax show boot [detail] Parameters detail - (Optional) Enter to display detailed information. Default Not configured Command Mode EXEC Usage Information - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 502
-10-03T23:11:14Z Next-Boot: active[B] Supported Releases 10.2.0E or later show image status Displays image transfer and installation information. Syntax Parameters Default Command Mode Usage Information Example show image status None Not configured EXEC None OS10# show image status Image - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 503
configured EXEC None OS10# show version Dell EMC Networking OS10 Enterprise Copyright (c) 1999-2018 by Dell Inc. All Rights Reserved. OS Version: 10.4.0E(R3) Build Version: 10.4.0E(R3.221) Build Time: 2018-03-25T22:20:52-0700 System Type: Z9100-ON Architecture: x86_64 Up Time: 02:22:09 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 504
assign numbers in the order you create the filters. The sequence numbers display in the show running-configuration and show ip access-lists [in | out] command output. Ingress and egress hot-lock entries. Hot-lock ACLs are enabled by default and support ACLs on all platforms. 504 Access Control Lists - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 505
service Present in the packet header IPv4/IPv6 and MAC ACLs apply separately for inbound and outbound packets. You can assign an interface to multiple ACLs, with a limit of one ACL per packet direction per ACL type. IP fragment handling OS10 supports a configurable a particular problem for ACL - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 506
any fragment To log all packets denied and to override the implicit deny rule and the implicit permit rule for TCP/ UDP fragments, use a similar configuration. When an ACL filters packets, it looks at the FO to determine whether it is a fragment: • FO = 0 means it is either the first fragment or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 507
} tcp {source mask] | any | host ip-address}} [count [byte]] [fragments] • Configure a deny or permit filter to examine UDP packets in IPV4-ACL mode. {deny | permit} udp seq 5 permit ip any any count (10000 packets) L2 and L3 ACLs Configure both L2 and L3 ACLs on an interface in L2 mode. Rules apply - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 508
ip-address 3 Apply an IP ACL filter to traffic entering or exiting an interface in INTERFACE mode. ip access-group access-list-name {in | out} Configure IP ACL OS10(config)# interface ethernet 1/1/28 OS10(conf-if-eth1/1/28)# ip address 10.1.2.0/24 OS10(conf-if-eth1/1/28)# ip access-group abcd - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 509
ingress ACL filter, use the ip access-group command in EXEC mode. To configure ingress, use the in keyword. Apply rules to the ACL with the ip access ACL filter to restrict egress traffic. For example, when a denial of service (DOS) attack traffic is isolated to a specific interface, apply an egress - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 510
applies and no additional filters apply to the route Use prefix-lists in processing routes for routing protocols such as OSPF, RTM, and BGP. To configure a prefix-list, use commands in PREFIX-LIST and ROUTER-BGP modes. Create the prefix-list in PREFIX-LIST mode and assign that list to commands - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 511
number, only the last match and set values are taken into account. Configure match metric OS10(config)# route-map hello OS10(conf-route-map)# to permit, the route is denied View both IP prefix-list and route-map configuration OS10(conf-router-bgp-neighbor-af)# do show ip prefix-list ip prefix-list - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 512
clauses: ip address prefix-list p2 Set clauses: route-map test4, permit, sequence 10 Match clauses: ip address prefix-list p2 Set clauses: Match routes Configure match criterion for a route-map. There is no limit to the number of match commands per route map, but keep the number of match filters - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 513
ingress interfaces are examined. Appropriate ACL rules apply in the ingress direction. By default, flow-based mirroring is not enabled. To enable the evaluation and replication of traffic traversing to the destination port, configure the monitor option with the permit, deny, or seq commands for ACLs - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 514
If you configure the flow-based enable command and do not apply an ACL on the source port or the monitored port, both flow-based monitoring and port mirroring do not function. Flow-based monitoring is supported only for ingress traffic. The show monitor session session-id command displays output - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 515
show access-lists command. OS10# clear ip access-list counters Supported Releases 10.2.0E or later clear ipv6 access-list counters Clears IPv6 access-list to clear counters. A maximum of 140 characters. Default Not configured Command Mode EXEC Usage Information If you do not enter an access - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 516
access list to clear counters. A maximum of 140 characters. Default Not configured Command Mode EXEC Usage Information If you do not enter an command. Example OS10# clear mac access-list counters Supported Releases 10.2.0E or later deny Configures a filter to drop packets with a specific IP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 517
address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets -ipv6-acl)# deny ipv6 any any capture session 1 Supported Releases 10.2.0E or later deny (MAC) Configures a filter to drop packets with a specific MAC address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 518
(conf-mac-acl)# deny any any vlan 2 Supported Releases 10.2.0E or later deny icmp Configures a filter to drop all or specific internet control IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 519
IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes acl)# deny icmp any any capture session 1 Supported Releases 10.2.0E or later deny ip Configures a filter to drop all or specific packets from - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 520
deny ip any any capture session 1 count Supported Releases 10.2.0E or later deny ipv6 Configures a filter to drop all or specific packets from IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 521
IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes deny tcp any any capture session 1 Supported Releases 10.2.0E or later deny tcp (IPv6) Configures a filter that drops TCP IPv6 packets meeting - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 522
the IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes; acl)# deny tcp any any capture session 1 Supported Releases 10.2.0E or later deny udp Configures a filter to drop user datagram protocol ( - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 523
acl)# deny udp any any capture session 1 Supported Releases 10.2.0E or later deny udp (IPv6) Configures a filter to drop UDP IPv6 packets that IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 524
traffic. • out - Apply the ACL to outgoing traffic. Default Command Mode Usage Information Example Not configured INTERFACE The no version of this command deletes an IP ACL configuration. OS10(conf-if-eth1/1/8)# ip access-group testgroup in Supported Releases 10.2.0E or later ip access-list - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 525
to match an AS-path route attribute. Defaults Command Mode Usage Information Not configured CONFIGURATION You can specify an access-list filter on brackets, start and end of a string. Workaround None; not supported in OS10. None; not supported in OS10. Use [[:punct:]] or "," (comma). The space - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 526
keyword for an Internet community. Defaults Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes the community list. OS10(config)# ip community-list standard STD_LIST deny local-AS Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 527
Enter the route origin or site-of-origin. Defaults Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes the 4byteas-generic transitive 1.65412:60 Supported Release 10.3.0E or later ip prefix-list description Configures a description of an IP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 528
- Enter the prefix length. Defaults Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes the specified prefix-list. OS10(config)# ip prefix-list denyprefix deny 10.10.10.2/16 le 30 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 529
prefix-len - Enter the prefix length. Defaults Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes deny 10.10.10.1/16 ge 10 Supported Release 10.3.0E or later ip prefix-list seq permit Configures a filter to permit route filtering from - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 530
traffic. • out - Apply the ACL to outgoing traffic. Default Command Mode Usage Information Example Not configured INTERFACE The no version of this command deletes an IPv6 ACL configuration. OS10(conf-if-eth1/1/8)# ipv6 access-group test6 in Supported Releases 10.2.0E or later ipv6 access-list - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 531
deny AB10::1/128 ge 10 le 30 Supported Release 10.3.0E or later ipv6 prefix-list description Configures a description of an IPv6 prefix-list. prefix-len - Enter the prefix length. Defaults Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 532
prefix-len - Enter the prefix length. Defaults Command Mode Usage Information Example Not configured CONFIGURATION The no version of this command removes 65535 deny AB20::1/128 ge 10 Supported Release 10.3.0E or later ipv6 prefix-list seq permit Configures a filter to permit route filtering - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 533
name of a MAC access list. A maximum of 140 characters. Default Not configured Command Mode CONFIGURATION Usage Information None Example OS10(config)# mac access-list maclist Supported Releases 10.2.0E or later permit Configures a filter to allow packets with a specific IP address. Syntax - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 534
IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes )# permit udp any any capture session 1 Supported Releases 10.2.0E or later permit (IPv6) Configures a filter to allow packets with a specific - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 535
acl)# permit udp any any capture session 1 Supported Releases 10.2.0E or later permit (MAC) Configures a filter to allow packets with a specific Enter the VLAN number, from 1 to 4093. Default Command Mode Usage Information Example Not configured MAC-ACL OS10 cannot count both packets and bytes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 536
IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and acl)# permit icmp any any capture session 1 Supported Releases 10.2.0E or later permit icmp (IPv6) Configures a filter to permit all or specific ICMP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 537
IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes acl)# permit ip any any capture session 1 Supported Releases 10.2.0E or later permit ipv6 Configures a filter to permit all or specific packets - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 538
permit ipv6 any any count capture session 1 Supported Releases 10.2.0E or later permit tcp Configures a filter to permit TCP packets meeting the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 539
IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes )# permit tcp any any capture session 1 Supported Releases 10.2.0E or later permit udp Configures a filter that allows UDP packets meeting the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 540
the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; permit udp any any capture session 1 Supported Releases 10.2.0E or later permit udp (IPv6) Configures a filter to permit UDP packets meeting - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 541
a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot Configure up to 16777214 remarks for a given IPv4, IPv6, or MAC. OS10(conf-ipv4-acl)# remark 10 Deny rest of the traffic OS10(conf-ipv4-acl)# remark 5 Permit traffic from XYZ Inc. Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 542
the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; (conf-ipv4-acl)# seq 10 deny tcp any any capture session 1 Supported Releases 10.2.0E or later seq deny (IPv6) Assigns a sequence number - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 543
conf-ipv6-acl)# seq 5 deny ipv6 any any capture session 1 count Supported Releases 10.2.0E or later seq deny (MAC) Assigns a sequence number to (Optional) VLAN number, from 1 to 4093. Default Command Mode Usage Information Example Not configured CONFIG-MAC-ACL OS10 cannot count both packets and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 544
IP address to use a host IP address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; OS10(conf-ipv4-acl)# seq 5 deny icmp any any capture session 1 Supported Releases 10.2.0E or later seq deny icmp (IPv6) Assigns a sequence - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 545
conf-ipv6-acl)# seq 10 deny icmp any any capture session 1 Supported Releases 10.2.0E or later seq deny ip Assigns a sequence number to the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 546
the IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes; (conf-ipv6-acl)# seq 10 deny ipv6 any any capture session 1 Supported Releases 10.2.0E or later seq deny tcp Assigns a filter to deny - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 547
the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; OS10(conf-ipv4-acl)# seq 10 deny tcp any any capture session 1 Supported Releases 10.2.0E or later seq deny tcp (IPv6) Assigns a filter to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 548
the IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes OS10(conf-ipv6-acl)# seq 10 deny tcp any any capture session 1 Supported Releases 10.2.0E or later seq deny udp Assigns a filter to deny - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 549
the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; OS10(conf-ipv4-acl)# seq 10 deny udp any any capture session 1 Supported Releases 10.2.0E or later seq deny udp (IPv6) Assigns a filter to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 550
-ipv6-acl)# seq 10 deny udp any any capture session 1 Supported Releases 10.2.0E or later seq permit Assigns a sequence number to Enter the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL The no version of this command removes the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 551
IPv6 address to be used as the host address. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes; conf-ipv6-acl)# seq 10 permit ipv6 any any capture session 1 Supported Releases 10.2.0E or later seq permit (MAC) Assigns a sequence - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 552
00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later seq permit icmp Assigns a sequence number to allow Enter the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 553
the IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes; conf-ipv6-acl)# seq 5 permit icmp any any capture session 1 Supported Releases 10.2.0E or later seq permit ip Assigns a sequence number - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 554
the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; conf-ipv4-acl)# seq 5 permit ip any any capture session 1 Supported Releases 10.2.0E or later seq permit ipv6 Assigns a sequence number to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 555
(Optional) Enter the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; when you enter )# seq 5 permit tcp any any capture session 1 Supported Releases 10.2.0E or later Access Control Lists 555 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 556
(Optional) Enter the IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes; when you enter )# seq 5 permit tcp any any capture session 1 Supported Releases 10.2.0E or later 556 Access Control Lists - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 557
(Optional) Enter the IP address to use a host address only. Default Command Mode Usage Information Example Not configured IPV4-ACL OS10 cannot count both packets and bytes; when you enter )# seq 5 permit udp any any capture session 1 Supported Releases 10.2.0E or later Access Control Lists 557 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 558
(Optional) Enter the IPv6 address to use a host address only. Default Command Mode Usage Information Example Not configured IPV6-ACL OS10 cannot count both packets and bytes; when you enter )# seq 5 permit udp any any capture session 1 Supported Releases 10.2.0E or later 558 Access Control Lists - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 559
name - Enter the name of the access group. Default Command Mode Usage Information Example (IP) Not configured EXEC None OS10# show ip access-group aaa list aaa on ethernet 4/0 Egress IPV6 access list aaa on ethernet 4/0 Supported Releases 10.2.0E or later show access-lists Displays IP, MAC, or - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 560
interfaces : ethernet 3/0 ethernet 3/1 seq 10 permit any any Egress IPV6 access list ggg Active on interfaces : ethernet 3/0 seq 5 permit ipv6 11::/32 any count (0 packets) Supported Releases 10.2.0E or later 560 Access Control Lists - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 561
access-list ip as-path access-list hello permit 123 deny 35 Supported Releases 10.3.0E or later show ip community-list Displays the configured IP community lists in alphabetic order. Syntax Parameters Defaults Command Mode Usage Information Example show ip community-list [name] name - (Optional - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 562
-list ipv6 prefix-list hello: seq 10 permit 1::1/64 seq 20 deny 2::2/64 Supported Releases 10.3.0E or later Route-map commands continue Configures the next sequence of the route map. Syntax Parameters Default Command Mode Usage Information Example continue seq-number seq-number - Enter the next - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 563
of an established AS-PATH ACL. A maximum of 140 characters. Default Not configured Command Mode ROUTE-MAP Usage Information The no version of this command -route-map)# match as-path pathtest1 Supported Releases 10.3.0E or later match community Configures a filter to match routes that have - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 564
- Enter the name of the configured access list. Default Command Mode Usage Information Example Not configured ROUTE-MAP The no version of this command deletes a match. OS10(config)# route-map bgp OS10(conf-route-map)# match ip address prefix-list test10 Supported Releases 10.3.0E or later 564 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 565
the name of the access group or list. Default Command Mode Usage Information Example Not configured ROUTE-MAP The no version of this command deletes the match. OS10(config)# route-map bgp OS10(conf-route-map)# match ipv6 address test100 Supported Releases 10.3.0E or later match ipv6 next-hop - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 566
-value - Enter a value to match the route metric against, from 0 to 4294967295. Default Not configured Command Mode ROUTE-MAP Usage Information The no version of this command deletes the match. Example OS10(conf-route-map)# match metric 429132 Supported Releases 10.2.0E or later match origin - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 567
- Match only on routes generated locally. Default Command Mode Usage Information Example Not configured ROUTE-MAP The no version of this command deletes the match. OS10(config)# route-map bgp OS10(conf-route-map)# match route-type external type-1 Supported Releases 10.3.0E or later match tag - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 568
-map bgp OS10(conf-route-map)# set comm-list comlist1 add Supported Releases 10.4.0E(R1) or later set comm-list delete Remove communities characters. Defaults None' Command Mode ROUTE-MAP Usage Information The community list you use in the set comm-list delete command must be configured so - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 569
bytes) and nn is a value specific to that AS. Default Command Mode Usage Information Example Not configured ROUTE-MAP The no version of this command deletes a BGP -map bgp OS10(conf-route-map)# set extcomm-list TestList add Supported Releases 10.4.0E(R1) or later set extcomm-list delete Remove - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 570
rt 10.10.10.2:325 Supported Releases 10.3.0E or later set local-preference Sets the preference value for the AS path. Syntax set local-preference value Parameters value - Enter a number as the LOCAL_PREF attribute value, from 0 to 4294967295. Default Not configured Command Mode ROUTE-MAP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 571
10 Example (Relative) OS10(conf-route-map)# set metric -25 Supported Releases 10.2.0E or later set metric-type Set the metric type local AS. • external - Disables advertisement to peers. Default Command Mode Usage Information Not configured ROUTE-MAP • BGP Affects BGP behavior only in outbound - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 572
ip-address - Enter the IPv4 or IPv6 address for the next-hop. Default Not configured Command Mode ROUTE-MAP Usage Information If you apply a route-map with configured ROUTE-MAP The no version of this command deletes the set clause from a route map. OS10(conf-route-map)# set origin egp Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 573
-map)# set weight 200 Supported Releases 10.2.0E or later show route-map Displays the current route map configurations. Syntax show route-map [map-name] Parameters map-name - (Optional) Specify the name of a configured route map. A maximum of 140 characters. Defaults None Command Mode EXEC - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 574
. The different QoS features control the above parameters, as traffic traverses a network device from ingress interfaces to egress interfaces. Configure quality of service Network traffic is processed based on classification and policies that are created and applied to the traffic. 574 Quality of - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 575
default)-Classifies the ingress data traffic. • queuing -Classifies the egress queues. • control-plane-Classifies the control-plane traffic. • network-qos-Classifies the set of traffic-class IDs for ingress buffer configurations on physical interfaces or on system-qos mode. Quality of service 575 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 576
default, OS10 does not classify data traffic and assigns the default supports and color for the CoS flow. Table 9. Default 802.1p CoS trust map CoS Traffic class ID default mapping by creating dot1p trust map. All the unspecified dot1p entries are mapped to the default traffic class ID 0. Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 577
-map NOTE: In the interface level, the no version of the command returns the configuration to system-qos level. If there is no configuration available at the system-qos level, then the configuration returns to default mapping. • System-qos level OS10(config-sys-qos)# trust-map dot1p dot1p-trust-map - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 578
. All the unspecified DSCP entries are mapped to the default traffic class ID 0. Configure user-defined DSCP trust map 1 Create a DSCP trust of precedence is: 1 Interface-level map 2 System-qos-level map 3 Default map Configure trust 1 Create a qos type policy-map. OS10(config)# policy-map trust - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 579
level OS10(conf-if-eth1/1/1)# service-policy input type qos trust • System-qos level OS10(config-sys-qos)# service-policy input type qos trust 1p CoS • VLAN ID (802.1.Q) • DSCP + ECN • IP precedence OS10 supports configuring a range of or comma separated values of match filters. When you apply the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 580
command or set its defaults police Rate police input traffic set Mark input traffic show show configuration trust Specify dynamic classification • Attach the policy-map to interface. OS10(conf-if-eth1/1/1)# service-policy input type qos cos-trust Control-plane policing Control-plane policing - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 581
CPU queues requires configuring control-plane type QoS policies. • Create QoS policies (class maps and policy maps) for the desired CPU-bound queue. • Associate the QoS policy with a particular rate-limit. • Assign the QoS service policy to control plane queues. By default, the peak information - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 582
input: copp1 Class-map (control-plane): copp set qos-group 2 police cir 100 bc 100 pir 100 be 100 Assign service-policy Rate controlling control traffic towards CPU requires configuring control-plane type policy. To enable CoPP, you need to apply the defined policy-map to CONTROL-PLANE mode. 1 Enter - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 583
configuration OS10# show class-map type control-plane cmap1 Class-map (control-plane): cmap1 (match-any) View CoPP service-policy OS10# show policy-map type control-plane Service mark it with a traffic class ID using a policy map. By default, the value of traffic class ID for all the traffic is 0. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 584
ID 2 3 4 5 6 7 User-defined QoS map You can override the default mapping by creating QoS map. Configure user-defined QoS map 1 Create a QoS map OS10(config)# qos-map traffic- When the traffic rate is above the configured peak-rate, the traffic is dropped to guarantee a bandwidth limit for an ingress traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 585
-all-traffic OS10(config-pmap-c-qos)#police cir 4000 pir 6000 Configure flow rate policing 1 Create a QoS type class-map to You can color the traffic flow based on: • Metering. See Policing traffic. • Default trust. See Trust based classification. • DSCP , ECN capable traffic (ECT), or service 585 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 586
traffic You can configure to shape configured threshold. Configure traffic shaping 1 Enter the policy-map type as queuing and configure a policy-map name in CONFIGURATION If you do not configure the match qos-group configure the priority command and configure a name for the class-map in CONFIGURATION mode. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 587
all packets from the assigned queue before servicing any other queues. When more than one queue is assigned strict priority, the highest number queue receives the highest priority. You can configure strict priority to any number of queues. By default, all queues schedule traffic per WDRR. You - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 588
conf-sys-qos)# service-policy output solar View QoS system OS10(conf-sys-qos)# do show qos system Service-policy (output)( configured ports. The following buffer pools are available: • Ingress buffer pools: - Lossy pool (default) - Lossless pool (PFC) • Egress buffer pools: - Lossy pool (default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 589
NA 36KB 142KB 9KB 9KB NOTE: The supported speed varies for different platforms. After the reserved buffers are utilized, each PFC starts consuming shared buffers from the lossless pool with the threshold determined by the alpha value. Configure priority group buffer settings Quality of service 589 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 590
-c-nqos)# pause buffer-size 300 pause-threshold 200 resume-threshold 100 OS10 (config-pmap-c-nqos)# queue-limit thresh-mode dynamic 5 Configure egress buffer Default settings All port queues are allocated with reserved buffers and when the reserved buffers are consumed, each queue starts using the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 591
to the queue (1 to 100). Default Not configured Command Mode POLICY-MAP QUEUE Usage Information If you configure this command, you cannot use the priority command for the class. Example OS10(conf-pmap-que)# bandwidth percent 70 Supported Releases 10.2.0E or later Quality of service 591 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 592
-map (up to 32 characters). Default Not configured Command Mode POLICY-MAP-QUEUEING POLICY- qos. OS10(conf-pmap-qos)# class c1 Supported Releases 10.2.0E or later class-map Creates name - Enter a class-map name (up to 32 characters). Defaults • qos - class-map type • match-any - class-map - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 593
PFC counters. Syntax Parameters Default Command Mode Usage Information Example clear qos statistics None Not configured EXEC None OS10# clear qos statistics Supported Releases 10.2.0E or queueing type statistics. • control-plane - Clears control-plane type statistics. Quality of service 593 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 594
type queuing interface ethernet 1/1/2 Supported Releases 10.2.0E or later control-plane Enters Control-Plane mode. Syntax control-plane Parameters None Default Not configured Command Mode CONTROL-PLANE port from sending flow control traffic to the remote device. 594 Quality of service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 595
value to the default. OS10(conf-if-eth1/1/2)# flowcontrol transmit on Supported Releases 10.3.0E or later match Configures match criteria for the ipv6 access-group name ACLv6 set dscp 40 Supported Releases 10.2.0E or later match cos Matches a cost of service (CoS) value to L2 dot1p packets. Syntax - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 596
or a hyphenated range (0 to 63). Default Command Mode Usage Information Example Not configured CLASS-MAP You cannot enter two match statements cmap-qos)# match ip-any dscp 17-20 Supported Releases 10.2.0E or later match precedence Configures IP precedence values as a match criteria. service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 597
match not ipv6 precedence 3 Supported Releases 10.2.0E or later match queue Configures a match criteria for a queue. Syntax Parameters Default Command Mode Usage Information Example match Example OS10(conf-cmap-qos)# match vlan 100 Supported Releases 10.2.0E or later Quality of service 597 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 598
the value to the default. Example OS10(conf-pmap-nqos-c)# mtu 2500 Supported Releases 10.3.0E or the value to the default. Add the policy-map with pause to system-qos to service an input to enable PG. Platform-specific default values are based on MTU sizes of 9216 and cable length of 100 meters - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 599
service (CoS). Syntax pfc-cos cos-value Parameters cos-value - Enter a single, comma-delimited, or hyphenated range of CoS values for priority flow-control to enable (0 to 7). Default Not configured -limit 140 Supported Releases 10.3.0E or later pfc-max-buffer-size Configures the maximum - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 600
this command returns the value to the default. OS10(conf-sys-qos)# pfc-shared-headroom-buffer-size 2000 Supported Releases 10.4.0E(R1) or later police Configures traffic policing on incoming traffic. Syntax Enter a peak-rate value in kilo bits per second (0 to 40000000). 600 Quality of service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 601
-map filter CONFIGURATION The no version of this command deletes a policy-map. OS10(config)# policy-map p1 Example (Queuing) OS10(config)# policy-map type queuing p1 Supported Releases 10.2.0E or later priority Sets the scheduler as a strict-priority. Syntax Parameters Default priority None - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 602
the value to the default. OS10(conf-if-eth1/1/2)# priority-flow-control mode on Supported Releases 10.3.0E or later qos-group dot1p Configures a dot1p trust map to value to the default. OS10(conf-tmap-dot1p-qos)# qos-group 5 dot1p 5 Supported Releases 10.3.0E or later 602 Quality of service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 603
value to the default. OS10(conf-tmap-dscp-qos)# qos-group 5 dscp 42 Supported Releases 10.3.0E or later queue-limit Configures static or dynamic (0 to 10). Defaults: - 0 = 1/128 - 1 = 1/64 - 2 = 1/32 - 3 = 1/16 - 4 = 1/8 - 5 = 1/4 - 6 = 1/2 - 7=1 - 8=2 - 9=4 - 10 = 8 Quality of service 603 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 604
thresh-mode static 50 Supported Releases 10.3.0E or later queue bandwidth Configures a bandwidth for a - Enter the percentage of bandwidth. Default Not configured Command Mode POLICY-MAP-CLASS-MAP Usage dot1p values (0 to 7). Default Command Mode 0 TRUST-MAP 604 Quality of service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 605
Default Not configured Command Mode INTERFACE Usage Information The no version of this command removes the WRED profile from the interface. Example OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# random-detect test_wred Supported : green, yellow, and red. Quality of service 605 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 606
) for the WRED profile. Syntax Parameters Default Command Mode Usage Information Example random-detect ecn None Not configured WRED CONFIGURATION The no version of this command disables ECN. OS10(config)# wred test_wred OS10(config-wred)# random-detect ecn Supported Releases 10.4.0E(R1) or later - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 607
15). Default Not configured Command Mode WRED CONFIGURATION Usage Information The no version of this command removes the weight factor from the WRED profile. Example OS10(config)# wred test_wred OS10(config-wred)# random-detect weight 10 Supported Releases 10.4.0E(R1) or later service-policy - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 608
drop. • yellow - (Optional) Enter to mark the packets to deliver to the egress queue. Default Command Mode Usage Information Example Not configured POLICY-MAP-CLASS-MAP The QoS ingress QoS policy type only supports this command. Packets marked as color yellow deliver to the egress queue, then the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 609
Supported or 1 to 1073000). Default Command Mode Usage Information Example Maximum burst ingress QoS policy type supports this command. You Supported Releases 10.2.0E or later show class-map Displays configuration map name. Default Command Mode Usage Information Not configured EXEC This command - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 610
10 Supported Releases 10.2.0E or later show control-plane info Displays control-plane queue mapping and rate limits. Syntax show control-plane info Parameters None Default Not configured Command Mode EXEC Usage Information Monitors statistics for the control-plane and to troubleshoot CoPP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 611
: 200 Cos Rx Tx 0 0 0 1 0 0 2 0 0 3 300 200 4 0 0 5 0 0 6 0 0 7 0 0 Supported Releases 10.3.0E or later show qos interface Displays the QoS configuration applied to a specific interface. Syntax Parameters Default Command Mode Usage Information Example show qos - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 612
to the control-plane. Syntax Parameters Default Command Mode Usage Information Example show qos control-plane None Not configured EXEC Monitors statistics for the control-plane and troubleshoots CoPP. OS10# show qos control-plane Service-policy (Input): p1 Supported Releases 10.2.0E or later 612 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 613
dynamic 8 7 lossy 1664 dynamic 8 Supported Releases 10.3.0E or later show egress Enter the port information. Default Command Mode Usage Information Example Not configured EXEC None OS10# show 1 0 0 0 0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Quality of service 613 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 614
the port information. Default Command Mode Usage Information Example Not configured EXEC None OS10(config - - 0 STATIC 0 0 0 5 - - 0 STATIC 0 0 0 6 - - 0 STATIC 0 0 0 7 - 0-2,5-7 8 STATIC 0 0 0 Supported Releases 10.3.0E or later show ingress buffer-stats service - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 615
Enter the QoS queue number (0 to 7). Default Command Mode Usage Information Example Not configured EXEC Use this command to view all queuing Interface ethernet1/1/1 Queue 3 Description Packets Bytes Output 0 0 Dropped 0 0 Supported Releases 10.2.0E or later Quality of service 615 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 616
system Parameters None Default Not configured Command Mode EXEC Usage Information View and verify system-level service-policy configuration information. Example OS10# show qos system Service-policy (Input) (qos) : policy1 Service-policy (Output)(queuing) : policy2 Supported Releases 10.2.0E - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 617
• trust-map - Enter the name of the trust map. Default Command Mode Usage Information Example (dot1p) Not configured EXEC None OS10# show qos maps type tc-queue queue-map1 : dot1p-trustmap1 Traffic-Class DOT1P Priority 0 2 1 3 2 4 3 5 4 6 5 7 6 1 Quality of service 617 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 618
Default Dot1p Priority to Traffic-Class Map Traffic-Class DOT1P Priority 0 1 1 0 2 2 3 3 4 4 5 5 6 6 7 7 Default 48-55 7 56-63 Default Traffic-Class to Queue Map Supported Releases 10.3.0E or later show qos wred-profile Displays the details of WRED profile configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 619
MAX D KB KB %| KB KB %| KB KB Supported Releases system qos Enters SYSTEM-QOS mode to configure system-level service policies. Syntax Parameters Default Command Mode Usage Information Example system qos None Not configured CONFIGURATION None OS10(config)# system qos OS10(config-sys - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 620
Default Not configured Command Mode CONFIGURATION Usage Information default-dscp-trust is a reserved trust-map name. If trust is enabled, traffic obeys this trust map. The no version of this command returns the value to the default. Example OS10(config)# trust dscp-map dscp-trust1 Supported - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 621
-name - Enter a name for the WRED profile. Default Not configured Command Mode CONFIGURATION Usage Information The no version of this command removes the WRED profile. Example OS10(config)# wred test_wred OS10(config-wred)# Supported Releases 10.4.0E(R1) or later Quality of service 621 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 622
aggregation group (LAG) terminations on two separate distribution or core switches and supporting a loop-free topology. • Allows a single device to use configurations must be identical on both sides of a trunk. External switches or servers with LACP see the VLT switches as a single virtual switch. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 623
two peer switches. VLT domain A VLT domain includes the VLT peer devices, VLT interconnect, and all port-channels in the VLT that connect to the attached devices. It is also associated with the configuration mode that you must use to assign VLT global parameters. • A VLT domain supports two node - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 624
VLTi ports are not supported as members of VLANs configured on only one peer. (Optional) After you configure a VLT domain on each peer switch and connect (cable) the two VLT Manually reconfigure the default VLT MAC address. Configure the VLT MAC address in both the VLT peers. 6 (Optional) Configure - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 625
supported on VLT ports. Before you configure VLT on peer switches, configure RSTP in the network. RSTP prevents loops during the VLT startup phase. • Enable RSTP on each peer node in CONFIGURATION mode. spanning-tree mode rstp Configure (default) Link Type: Point-to-Point BPDU Sent: 15, - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 626
supported on VLT ports. Before you configure VLT on peer switches, configure RPVST+ in the network. You can use RPVST+ for initial loop prevention during the VLT startup phase. Configure RPVST+ on both the VLT peers. This creates an RPVST+ instance for every VLAN configured : No (default) Link Type - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 627
)# vlt-domain 1 OS10(conf-vlt-1)# discovery-interface ethernet1/1/1 OS10(conf-vlt-1)# discovery-interface ethernet1/1/2 Configure VLT port-channel A VLT port-channel links an attached device and VLT peer switches, also known as a virtual link trunk. 1 Enter the port-channel ID number on the VLT - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 628
of the VLT peer are locally routed. VLT unicast routing is supported for IPv4 and IPv6. To enable VLT unicast routing, both VLT peers must be in L3 mode. The VLAN configuration must be symmetrical on both peers. You cannot configure the same VLAN as L2 on one node and as L3 on - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 629
OS10(conf-if-vl-10)# vrrp mode active-active View VRRP configuration OS10# show running-configuration interface vlan 10 ! interface vlan10 no shutdown no vrrp mode active-active OS10# Migrate VMs across data centers OS10 does not support proxy gateway. Instead of proxy gateway, use VRRP in VLANs to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 630
-group ID. When a virtual machine running in Server Rack 1 migrates to Server Rack 2, L3 packets for that VM are routed through the default gateway. Sample configuration of C1: • Configure VRRP on L2 links between core routers: C1(config)# interface vlan 100 C1(conf-if-vl-100)# ip address 10.10.100 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 631
-group 20 D1(conf-if-eth1/1/5)# exit D1(config)# interface ethernet 1/1/6 D1(conf-if-eth1/1/6)# channel-group 20 D1(conf-if-eth1/1/6)# exit Sample configuration of C2: • Configure VRRP on L2 links between core routers: C2(config)# interface vlan 100 C2(conf-if-vl-100)# ip address 10.10.100.3/24 C2 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 632
-group 20 C2(conf-if-eth1/1/5)# exit C2(config)# interface ethernet 1/1/6 C2(conf-if-eth1/1/6)# channel-group 20 C2(conf-if-eth1/1/6)# exit Sample configuration of D2: • Configure VRRP on L2 links between core routers: D2(config)# interface vlan 100 D2(conf-if-vl-100)# ip address 10.10.100.4/24 D2 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 633
mismatch Peer-routing mismatch: No mismatch VLAN mismatch: No mismatch VLT VLAN mismatch: No mismatch View VLT mismatch - mismatch in VLT configuration OS10# show vlt 1 mismatch peer-routing Peer-routing mismatch: VLT Unit ID Peer-routing * 1 Enabled 2 Disabled OS10# show vlt 1 mismatch - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 634
port-channel 10 ! interface port-channel10 vlt-port-channel 20 ! interface port-channel20 vlt-port-channel 20 VLT commands backup destination Configures the VLT backup link for heartbeat timers. Syntax backup destination {ip-address | ipv6 ipv6-address} [vrf management] Parameters • ip-address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 635
device is reloaded. The no version of this command resets the delay time to the default value. Example OS10(conf-vlt-1)# delay-restore 100 Supported Releases 10.3.0E or later discovery-interface Configures the interface to discover and connect to a VLT peer in the VLT interconnect (VLTi) link - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 636
. OS10(conf-vlt-1)# peer-routing Supported Releases 10.2.0E or later peer-routing-timeout Configures the delay after which peer routing is disabled when the peer is not available. This command is applicable for both IPv6 and IPv4. Syntax Parameters Default Command Mode Usage Information peer - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 637
state: 1 Edge port: No (default) Link Type: Point-to-Point BPDU Sent: 101, Received: 21 Supported Releases 10.3.0E or later show vlt Displays information on a VLT domain. Syntax Parameter Default show vlt id id - Enter a VLT domain ID, from 1 to 255. Not configured Virtual link trunking 637 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 638
spanned-vlans. Syntax Parameters Default Command Mode Usage Information show vlt mac-inconsistency None Not configured EXEC Use this command to check mismatch of MAC address table entries between VLT peers. To verify VLT configuration mismatch issues on peer switches, use the show vlt domain - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 639
to identify configuration issues Supported Releases 10.2.0E or later show vlt mismatch Displays mismatches in a VLT domain configuration. Syntax show mismatches in VLT port configuration, from 1 to 4095. Default Command Mode Usage Information Example (no mismatch) Not configured EXEC The * in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 640
VLT Unit ID Mismatch VLAN List * 1 1 2 2 Supported Releases 10.2.0E or later show vlt role Displays the VLT role of the local peer. Syntax show vlt id role Parameters id - Enter the VLT domain ID, from 1 to 255. Default Not configured Command Mode EXEC Usage Information The * in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 641
-channel2 down 1 0 VLT ID : 3 VLT Unit ID Port-Channel Status Configured ports Active ports 2 port-channel3 down 1 0 Supported Releases 10.2.0E or later vlt-domain Creates a VLT domain. Syntax Parameter Default Command Mode Usage Information Example vlt-domain domain-id domain-id - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 642
vlt-port-channel 1 Example (peer 2) OS10(conf-if-po-20)# vlt-port-channel 1 Supported Releases 10.2.0E or later vlt-mac Configures a MAC address for all peer switches in a VLT domain. Syntax Parameters Default Command Mode Usage Information vlt-mac mac-address mac-address - Enter a MAC address - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 643
center services OS10 supports converged data center services, including system interface (iSCSI) Use iSCSI auto-configuration and detection of storage devices, monitor ensures that specified priority traffic is not dropped by the switch. PFC enhances the existing 802.3x pause capability to enable - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 644
Decide if you want to use the default 802.1p priority-to-traffic class (qos-group) mapping or configure a new map. By default, the qos class-trust class map is applied to ingress traffic. Class-trust is a reserved class name. The class-trust class instructs OS10 interfaces to honor dot1p or DSCP - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 645
policy to ingress traffic in SYSTEM-QOS or INTERFACE mode. service-policy input type qos trust-policy-map-name Configure a non-default dot1p-priority-to-traffic class mapping 1 Configure a trust map of dot1p traffic classes in CONFIGURATION mode. A trust map does not modify ingress dot1p values in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 646
traffic-class-to-queue mapping. See PFC configuration notes to change the default settings. Configuration steps: 1 Create PFC dot1p traffic classes. 2 Configure ingress buffers for PFC traffic. 3 Apply a service policy and enable PFC. 4 (Optional) Configure the PFC shared buffer for lossless traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 647
default settings. OS10(config)# system qos OS10(config-sys-qos)# trust-map dot1p default OS10(config)# system qos OS10(config-sys-qos)# service service-policy input type network-qos pp1 OS10(conf-if-eth1/1/1)# priority-flow-control mode on OS10(conf-if-eth1/1/1)# no shutdown View PFC configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 648
Configures traffic (0 to 7787). Defaults The default ingress-buffer size reserved for default ingress-buffer size, and pause (XON) and resume (XOFF) thresholds. Default port speeds. The default values are based on the default MTU size of Supported Releases 10.3.0E or later 648 Converged data center - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 649
classes. See PFC configuration notes for the default dot1p-priority-to-traffic-class mapping and how to configure a non-default mapping. A PFC traffic Supported Releases 10.3.0E or later pfc-shared-buffer-size Configures the amount of shared buffers available for PFC-enabled traffic on the switch - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 650
Default -class map, use the default buffer-size values if you flow-control mode on Supported Releases 10.3.0E or to 10). Default Command Mode queues on the switch, use the pfc Supported Releases 10.3.0E or later show interface priority-flow-control Displays PFC operational status, configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 651
Parameters Default Command Mode Usage Information Example (details) None Not configured EXEC 3 0 587236 4 0 0 5 0 0 6 0 0 7 0 0 Supported Releases 10.3.0E or later Enhanced transmission selection Enhanced transmission selection (ETS) provides customized center services 651 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 652
the L2 and L3 priority fields in ingress traffic by default. Create a trust map to honor dot1p and DSCP classes Configure a service policy to trust dot1p values in ingress traffic. - Egress queuing policy - Configure are supported. ETS configurations are received in a TLV from a peer. Configure ETS - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 653
queue mapping globally on the switch in SYSTEM-QOS mode service-policy output type queuing policy-map-name 9 Enable ETS globally in SYSTEM-QOS mode or on an interface/interface range in INTERFACE mode. ets mode on Configure config-sys-qos)# trust-map dot1p default OS10(config)# class-map type queuing - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 654
Usage Information Enable ETS on all switch interfaces in SYSTEM-QOS mode or on an interface or interface range in INTERFACE mode. The no version of this command disables ETS. Example OS10(config-sys-qos)# ets mode on Supported Releases 10.3.0E or later 654 Converged data center services - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 655
ports, • DCBX is disabled at a global level by default. Enable DCBX globally on a switch to activate the exchange of DCBX TLV messages with PFC, ETS, and iSCSI configurations. • DCBX is enabled by default on OS10 interfaces. You can manually reconfigure DCBX settings on a per-interface basis. For - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 656
switch. Misconfiguration detection is feature-specific because some DCB features support asymmetric (non-identical) configurations. Configure DCBX DCBX allows data center devices to advertise and exchange configuration settings with directly connected peers using LLDP. LLDP is enabled by default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 657
status OS10# show lldp dcbx interface ethernet 1/1/15 ets detail Interface ethernet1/1/15 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on Admin Parameters 0% SP 4 0% SP 5 0% SP 6 0% SP 7 0% SP 15 0% SP Remote Parameters : Converged data center services 657 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 658
Parameters None Default Disabled Command Mode CONFIGURATION Usage Information DCBX ETS, and iSCSI configurations. Use DCBX interfacelevel commands to configure the TLVs advertised configuration using LLDP and self-configure with compatible settings. If you disable DCBX globally on a switch - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 659
configuration TLVs. • ets-reco - Advertise ETS recommendation TLVs. • pfc - Advertise PFC TLVs. Default Configuration TLVs. INTERFACE A DCBX-enabled port advertises all TLVs to DCBX peers by default Supported Releases 10.3.0E or later dcbx version Configures version cee Supported Releases 10.3. - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 660
Supported Releases 10.3.0E or later show lldp dcbx interface Displays DCBX configuration with DCBX peers. Default Not configured Command Mode EXEC Manual DCBX Operational Status is Enabled Is Configuration Source? FALSE Local DCBX Compatibility mode is IEEEv2.5 Local DCBX Configured services - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 661
Example (ETS detail) OS10# show lldp dcbx interface ethernet 1/1/15 ets Interface ethernet1/1/15 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on detail Admin Parameters Admin is list is 4,5,6,7 Remote is enabled, Priority list is 4,5,6,7 Converged data center services 661 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 662
directly attached to switch ports. To support storage arrays where auto-detection is not supported, manually configure iSCSI optimization using the iscsi profilestorage name command. iSCSI optimization enables a switch to auto-detect Dell's iSCSI storage arrays and auto-configure switch ports to - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 663
to an interface. iSCSI automatically configures switch parameters after connection to a storage device is verified. You must manually enable an interface to support a storage device that is directly connected to a port, but not automatically detected by iSCSI. • By default, iSCSI monitoring sessions - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 664
devices that do not support LLDP. The switch auto-detects and auto-configures Dell EqualLogic storage arrays Configure the QoS policy applied to the ingress iSCSI flows. Apply the service policy to ingress interfaces in CONFIGURATION mode. (Optional) Reset the default CoS dot1p priority (default - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 665
priority-bits 0x20 OS10(config)# iscsi enable View iSCSI optimization OS10# show iscsi iSCSI Auto configuration is Enabled iSCSI session monitoring is Enabled iSCSI COS qos-group 4 remark dot1p 4 Session and the connection is associated with the interface. Converged data center services 665 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 666
Supported Releases 10.3.0E or later iscsi enable Enables iSCSI auto-detection of attached storage arrays and switch auto-configuration. Syntax iscsi enable Parameter None Default traffic in iSCSI application TLVs (0x1 to 0xff). Default 0x10 (dot1p 4) 666 Converged data center services - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 667
Enter a user-defined name of a storage array that iSCSI does not automatically detect. Default Not configured Command Mode INTERFACE Usage Information Configure directly attached storage arrays to be supported by iSCSI if they are not automatically detected. This command is required for storage - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 668
iSCSI application TLVs advertise dot1p 4 by default only if you configure dot1p 4 as a PFC priority with the pfc-cos command. The no version of this command disables iSCSI TLV transmission. Example OS10(conf-if-eth1/1/1)# lldp tlv-select dcbxp-appln iscsi Supported Releases 10.3.0E or later show - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 669
iscsi session command to view target and initiator information. OS10# show iscsi iSCSI Auto configuration is Enabled iSCSI session monitoring is Enabled iSCSI COS qos-group 4 remark dot1p .10.210 54835 10.10.10.40 3260 1 Supported Releases 10.3.0E or later Converged data center services 669 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 670
-MEM true Supported Releases 10.3.0E configuration (global) Configure DCBX globally on a switch to enable the exchange of DCBX TLV messages with PFC, ETS, and iSCSI configurations. OS10# configure terminal OS10(config)# dcbx enable 2. PFC configuration (global) 670 Converged data center services - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 671
-c-qos)# end 3. PFC configuration (interface) Apply the service policies with dot1p trust and PFC configurations to an interface. OS10(config dot1p values in output flows. The reserved class-trust class map is configured by default. OS10(config)# trust dot1p-map tmap1 OS10(config-tmap-dot1p-map)# - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 672
dot1p OS10(config-pmap-c-qos)# end 5. ETS configuration (interface and global) Apply the service policies with dot1p trust and ETS configurations to an interface or on all switch interfaces. Only one qos-map traffic-class map is supported on a switch. OS10(config)# interface ethernet 1/1/53 OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 673
Manual DCBX Operational Status is Enabled Is Configuration Source? FALSE Local DCBX Compatibility mode is IEEEv2.5 Local DCBX Configured configuration and operation OS10(conf-if-eth1/1/53)# do show lldp dcbx interface ethernet 1/1/53 ets detail Interface ethernet1/1/53 Max Supported services 673 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 674
TLV Pkts 10. iSCSI optimization configuration (global) This example accepts the default settings for aging time and iSCSI traffic to 6 globally on the switch. By default, iSCSI traffic uses priority 4. The system qos OS10(config-sys-qos)# service-policy type application policy-iscsi OS10(config - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 675
mode is CEE Local DCBX Configured mode is CEE Peer Operating version is CEE Local DCBX TLVs Transmitted: ErPfi Local DCBX Status DCBX Operational Version is 0 DCBX Max Version Supported is 0 Sequence Number: 2 Acknowledgment Number: 1 Protocol State: In-Sync Converged data center services 675 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 676
/1/53)# dcbx version cee OS10(conf-if-eth1/1/53)# show configuration ! interface ethernet1/1/53 switchport access vlan 1 no shutdown dcbx version ieee service-policy input type network-qos test service-policy input type qos pclass service-policy output type queuing pmap1 ets mode on qos-map traffic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 677
switches and routers. • OS10 supports sFlow version 5 • sFlow collector is supported only on data ports • A maximum of two sFlow collectors • OS10 does not support default. • Enable sFlow globally on all interfaces in CONFIGURATION mode. sflow enable all-interfaces • Disable sFlow in CONFIGURATION - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 678
are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval: 20 Global default extended maximum header size: 128 bytes Global extended information enabled: none 1 collector(s) configured Collector IP addr:10.16.151.245 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 679
are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval: 200 Global default extended maximum header size: 128 bytes Global extended information enabled: none 1 collector(s) configured Collector IP addr:10.16.151 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 680
release does not support the statistics for UDP packets dropped. • View sFlow configuration details and statistics in EXEC mode. OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 681
is the IPv4 or IPv6 address used to identify the agent to the collector. The no version of this command removes the configured sFlow collector. Example OS10(conf)# sflow collector 10.1.1.1 agent-addr 2.2.2.2 6343 max-datagram-size 1500 vrf default Supported Releases 10.3.0E or later sFlow 681 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 682
size in bytes, from 64 to 256. The default is 128. Default 128 bytes Command Mode CONFIGURATION Usage Information Example Use the no version of the command to reset the header size to the default value. OS10(conf)# sflow max-header-size 256 Supported Releases 10.3.0E or later sflow polling - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 683
statistics. The no version of the command resets the interval time to the default value. Example OS10(conf)# sflow polling-interval 200 Supported Releases 10.3.0E or later sflow sample-rate Configures the sampling rate. Syntax sflow sample-rate value Parameter value - Enter the packet - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 684
0 UDP packets dropped 34026 sFlow samples collected Example (portchannel) OS10# show sflow interface port-channel 1 port-channel1 sFlow is enabled on port-channel1 Samples rcvd from h/w: 0 Supported Releases 10.3.0E or later 684 sFlow - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 685
OS10 Critical workloads and applications require constant availability. Dell EMC Networking offers tools to help you monitor and troubleshoot problems before they happen. Packet and flow capture Metrics measurement Analysis and reporting Alerting Logging Performance monitoring Mapping and - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 686
.18 snmpd 30452 admin 20 0 22076 2524 2100 R 6.1 0.1 0:00.02 top 1 root 20 0 112100 5840 3032 S 0.0 0.1 0:12.32 systemd 2 root 20 0 0 0 0 S 0.0 0.0 0:00.00 kthreadd 686 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 687
write captured packets to a file, use the -w parameter. To read the captured file output offline, you can use open source software packages such as wireshark. Troubleshoot OS10 687 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 688
, you send packets to a destination and wait for a response. If there is no response, the destination is not active. The ping command is useful during configuration if you have problems connecting to a hostname or IP address. 688 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 689
126) 005.000 ms 001.000 ms 001.000 ms 3 fw-sjc-01.Dell Networking.com (10.11.127.254) 000.000 ms 000.000 ms 000.000 ms 4 www.Dell Networking.com (10.11.84.18) 000.000 ms 000.000 ms 000 :100:201:e8ff:fe00:4c8b, 64 hops max, 60 byte packets Hops Hostname Probe1 Probe2 Probe3 Troubleshoot OS10 689 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 690
is used to view the current hash algorithms configured for LAG and ECMP. View environment OS10# 5 System Inlet Ambient-3 temp sensor 26 1 6 Switch board 2 temp sensor 31 1 7 Switch board 3 temp sensor 41 1 8 NPU temp sensor : up : 1 : : off : S4048 : S4048 : 690 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 691
/slot/port[:subport] - Enter the ethernet interface number. • on | off - Set the interface LED to be on or off. Default Command Mode Usage Information Example Not configured EXEC Use the location-led interface command to change the location LED for the specified interface. OS10# location-led - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 692
Default Command Mode Usage Information Example Not configured EXEC Use the location-led system command to change the location LED for the specified system ID. OS10# location-led system 1 on OS10# location-led system 1 off Supported does not set the Don't Fragment (DF) flag. 692 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 693
diagnose data-related problems in the network service (QoS)-related bits. • -s packetsize - (Optional) Enter the number of data bytes to send (1 to 65468, default 56). • -S sndbuf - (Optional) Set the sndbuf socket. By default Default Command Mode Usage Information Not configured Supported Troubleshoot - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 694
out the packet you send to diagnose data-related problems in the network (for example, -p ff fills the service (QoS)-related bits. • -s packetsize - (Optional) Enter the number of data bytes to send (1 to 65468, default 56). • -S sndbuf - (Optional) Set the sndbuf socket. By default Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 695
Supported Releases 10.2.0E or later show boot Displays boot partition-related information. Syntax show boot [detail] Parameters detail - (Optional) Enter to display detailed information. Default Not configured Next-Boot: active[B] Supported Releases 10.2.0E or later Troubleshoot OS10 695 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 696
environment Displays information about environmental system components, such as temperature, fan, and voltage. Syntax Parameters Default Command Mode Usage Information Example show environment None Not configured EXEC None OS10# show environment Unit State Temperature 696 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 697
Switch board 2 temp sensor 31 1 7 Switch board 3 temp sensor 41 1 8 NPU temp sensor 43 Supported Releases 10.2.0E or later show hash-algorithm Displays hash algorithm information. Syntax show hash-algorithm Parameters None Default Not configured -FAN10-058-901 Troubleshoot OS10 697 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 698
. • process-id - (Optional) Enter the process ID number . Default Command Mode Usage Information Example Not configured EXEC None OS10# show processes node-id 1 top - 09:19:32 up 73508 S 6.6 6.4 1212:36 base_nas OS10# Supported Releases 10.3.0E or later 698 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 699
of system information. • node-id - Node ID number. Default Command Mode Usage Information Example Not configured EXEC None OS10#show system Node Id MAC Number of MACs node-id 1 fanout-configured Interface Breakout capable Breakout state Eth 1/1/1 Yes BREAKOUT_1x1 Troubleshoot OS10 699 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 700
-- FanTray Status AirFlow Fan Speed(rpm) Status 1 up REVERSE 1 13063 up 2 13020 up 2 up REVERSE 1 12956 up 2 12977 up 3 up NORMAL 1 12956 up 2 13063 up Supported Releases 10.2.0E or later 700 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 701
to accelerate traceroute (default 16). - -t tos - (Optional) For IPv4, enter the Type of Service (TOS) and default 60 bytes for IPv4 and 80 for IPv6). Default Command Mode Usage Information Example Not configured EXEC None OS10# traceroute www.dell.com traceroute to www.dell Troubleshoot OS10 701 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 702
, then enter your new password. root@OS10: /# reboot -f Rebooting.[ 822.327073] sd 0:0:0:0: [sda] Synchronizing SCSI cache [ 822.340656] reboot: Restarting system [ 822.344339] reboot: machine restart BIOS (Dell Inc) Boot Selector S6010-ON (SI) 3.20.0.3 (32-port TE/FG) 702 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 703
storage device: /dev/mmcblk0 (7832MB) Percent complete: 100% SupportAssist By default, SupportAssist is enabled. SupportAssist sends troubleshooting data securely to Dell Technical Support. SupportAssist does not support automated email notification at the time of hardware fault alert, automatic - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 704
agreement by configuring this command 'eula-consent support-assist reject.' By installing SupportAssist, you allow Dell to save your contact information (e.g. name, phone number and/or email address) which would be used to provide technical support for your Dell products and services. Dell may use - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 705
mode. You can set the name, email addresses, phone, method, and time zone. SupportAssist contact-person configurations are optional for the SupportAssist service. 1 (Optional) Enter the contact name in SUPPORT-ASSIST mode. contact-person first firstname last lastname 2 Enter the email addresses in - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 706
full-transfer schedule yearly month 6 day 12 hour 6 min 30 Set default activity schedule OS10(conf-support-assist)# no support-assist-activity full-transfer schedule View status Display the SupportAssist configuration status, details, and EULA information using the show commands. 1 Display the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 707
configuring this command 'eula-consent support-assist reject.' By installing SupportAssist, you allow Dell to save your contact information (e.g. name, phone number and/or email address) which would be used to provide technical support for your Dell products and services. Dell Troubleshoot OS10 707 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 708
for the contact person. Default Command Mode Usage Information Example Not configured SUPPORT-ASSIST The no version of this command removes the configuration. OS10(conf-support-assist-Eureka)# contact-person first "John James" last Smith Supported Releases 10.2.0E or later 708 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 709
eula-consent {support-assist} {accept | reject} • support-assist - Enter to accept or reject the EULA for the service. • accept - Enter to accept the EULA-consent. • reject - Enter to reject EULA-consent. Default Command Mode Usage Information Example (Accept) Not configured CONFIGURATION If you - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 710
non-configurable default server. Use the show support-assist status command to view the server configuration. The no version of this command removes the remote server. Example OS10(conf-support-assist)# server url https://eureka.com:444 Supported Releases 10.2.0E or later 710 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 711
otherwise use SupportAssist. (END) Supported Releases 10.2.0E or later show support-assist status Displays SupportAssist status information including activities and events. Syntax show support-assist status Parameters None Default Not configured Command Mode EXEC Troubleshoot OS10 711 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 712
. • port-channel channel-id - Enter a port-channel ID (1 to 28). • vlan vlan-id - Enter a VLAN ID (1 to 4093). Default Command Mode Usage Information A source interface is not configured. SUPPORT-ASSIST The no version of this command removes the configured source interface. 712 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 713
). Default Not configured Command Mode SUPPORT-ASSIST configuration. Example OS10(conf-support-assist-Eureka)# street-address "One Dell Way" "Suite 100" Supported Releases 10.2.0E or later support Default Command Mode Weekly on Sunday at midnight (hour 0 minute 0) EXEC Troubleshoot OS10 713 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 714
support-assist-activity full-transfer schedule daily hour 22 min 50 Supported Releases 10.2.0E or later territory Configures the territory for the company. Syntax Parameters Default Dell Technical Support. To send Dell Technical Support troubleshooting details about the Linux system configuration - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 715
support-bundle Generates an sosreport tar file that collects configuration and diagnostic information on Linux systems. Syntax Parameters Defaults Command Mode Usage Information Example generate support if left unchecked, might cause system service interruption or performance degradation. A minor - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 716
logging and reset the minimum logging severity to the default in CONFIGURATION mode. no logging server severity • Re-enable any logging command in CONFIGURATION mode. no logging enable Enable server logging for log notice OS10(config)# logging server dell.com severity log-notice View system logs The - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 717
and alarm information is sent to the syslog server, if one is configured. The show logging command accepts the following parameters: • log-file Jun 1 05:01:46 %Node.1-Unit.1:PRI:OS10 %log-notice:ETL_SERVICE_UP: ETL service is up Jun 1 05:02:06 %Node.1-Unit.1:PRI:OS10 %log-notice: Troubleshoot - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 718
link-bundle-trigger-threshold 10 View link-bundle monitoring threshold configuration OS10(config)# do show running-configuration link-bundle-trigger-threshold 10 ! ... Show link- alarm-index - Enter the alarm ID to clear the alarm. Default Not configured Command Mode EXEC 718 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 719
Supported Releases 10.2.0E or later show alarms Displays all current active system alarms. Syntax Parameters Default Command Mode Usage Information Example show alarms None Not configured true State: raised Active-alarm details - 1 Index: 1 Sequence Number: 5 Troubleshoot OS10 719 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 720
Description: Raise-time: Clear-time: New: State: Supported Releases 10.2.0E or later warning 1081364 Node.1-Unit.1 Default Not configured Command Mode EXEC Usage Information Use the alarm-id to clear and view alarm details. Example OS10# show alarms index 1 720 Troubleshoot - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 721
52 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms severity warning - Warning alarm severity. Default Command Mode Usage Information Example (Warning) Not configured EXEC None OS10# show alarms : Raise-time: Sep 20 0:1:5 Troubleshoot OS10 721 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 722
in the logging buffer. Syntax clear logging log-file Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# clear logging log-file Proceed to clear the log file [confirm yes/no(default)]: Supported Releases 10.2.0E or later 722 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 723
To disable the logging capability, use the no logging enable command. Parameters Default Command Mode Usage Information Example None Enabled CONFIGURATION The no version of this command disables all logging. OS10(config)# logging enable Supported Releases 10.2.0E or later Troubleshoot OS10 723 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 724
Default Command Mode Usage Information Example Log-notice CONFIGURATION None OS10(config)# logging log-file disable Example (Enable) OS10(config)# logging log-file enable Example (Severity) OS10(config)# logging log-file severity log-notice Supported conditions (default). 724 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 725
log-info - Informational messages. - log-debug - Debug messages. Defaults Command Mode Usage Information Example Log-notice CONFIGURATION Starting from 10.3.0E or later, this command supports IPv6 addresses. The previous versions support only IPv4 addresses. The no version of this command deletes - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 726
Optional) Enter the number of lines to include in the logging messages (1 to 65535). Default Command Mode Usage Information Example (Log-File) None EXEC The output from this command is dn_lacp dn_i3 dn_supportassis --More-- Supported Releases 10.2.0E or later 't be conv 726 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 727
.c:nl_to_nei --More-Supported Releases 10.2.0E or later Log into OS10 device Linux shell access is available for troubleshooting and diagnostic purposes only. Use linuxadmin for both the default user name and password. For security reasons, you must change the default linuxadmin password during the - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 728
with your device or the platform-specific Installation Guide on the Dell Support page (see dell.com/ support). Hardware What are the default console settings for ON-Series devices? • Set the data rate to 115200 baud • Set the data format to 8 bits, stop bits to 1, and no parity 728 Troubleshoot OS10 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 729
a list of current users. How do I view RADIUS transactions to troubleshoot problems? Use the debug radius command. How do I view the current DHCP binding information? Use the show ip dhcp binding command. Layer 2 How do I view the VLAN running configuration? Use the show vlan command to view all - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 730
configuration command. How do I view summary information for the OSPF database? Use the show ip ospf database command. How do I view configuration configuration? Use the show running-configuration command to view all currently configured access-list commands. Quality of service What are the QoS error - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 731
threshold should be greater than equal to Resume threshold. PFC cost of service error messages: • % Error: Not enough buffers are available, if SupportAssist is enabled? Use the show support-assist status command to view current configuration information. How can I view a list Troubleshoot OS10 731 - Dell MX5108n | OS10 Enterprise Edition User Guide for PowerEdge MX IO Modules Re - Page 732
tag or express service code, pull out the luggage tag on the chassis or enter the show chassis command from the CLI. • To receive additional kinds of technical support, click Contact Us, then click Technical Support. To access system documentation, see www.dell.com/manuals/. To search for drivers
OS10 Enterprise Edition User Guide —
PowerEdge MX I/O Modules
Release 10.4.0E(R3S)