HP Dc5700 HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition - Page 60

Personal Grounding Methods and Equipment, 2.4 Grounding the Work Area

Page 60 highlights

Identifying the Chassis, Routine Care, and Disassembly Preparation 5.2.3 Personal Grounding Methods and Equipment Use the following equipment to prevent static electricity damage to equipment: ■ Wrist straps are flexible straps with a maximum of one-megohm ± 10% resistance in the ground cords. To provide proper ground, a strap must be worn snug against bare skin. The ground cord must be connected and fit snugly into the banana plug connector on the grounding mat or workstation. ■ Heel straps/Toe straps/Boot straps can be used at standing workstations and are compatible with most types of shoes or boots. On conductive floors or dissipative floor mats, use them on both feet with a maximum of one-megohm ± 10% resistance between the operator and ground. Static Shielding Protection Levels Method Voltage Antistatic plastic Carbon-loaded plastic Metallized laminate 1,500 7,500 15,000 5.2.4 Grounding the Work Area To prevent static damage at the work area, use the following precautions: ■ Cover the work surface with approved static-dissipative material. Provide a wrist strap connected to the work surface and properly grounded tools and equipment. ■ Use static-dissipative mats, foot straps, or air ionizers to give added protection. ■ Handle electrostatic sensitive components, parts, and assemblies by the case or PCB laminate. Handle them only at static-free work areas. ■ Turn off power and input signals before inserting and removing connectors or test equipment. ■ Use fixtures made of static-safe materials when fixtures must directly contact dissipative surfaces. ■ Keep work area free of nonconductive materials such as ordinary plastic assembly aids and Styrofoam. ■ Use field service tools, such as cutters, screwdrivers, and vacuums, that are conductive. 5.2.5 Recommended Materials and Equipment Materials and equipment that are recommended for use in preventing static electricity include: ■ Antistatic tape ■ Antistatic smocks, aprons, or sleeve protectors ■ Conductive bins and other assembly or soldering aids ■ Conductive foam ■ Conductive tabletop workstations with ground cord of one-megohm +/- 10% resistance ■ Static-dissipative table or floor mats with hard tie to ground ■ Field service kits 5-4 437804-001 Service Reference Guide, dc5700

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

5–4
437804-001
Service Reference Guide, dc5700
Identifying the Chassis, Routine Care, and Disassembly Preparation
5.2.3 Personal Grounding Methods and Equipment
Use the following equipment to prevent static electricity damage to equipment:
Wrist straps
are flexible straps with a maximum of one-megohm ± 10% resistance in the
ground cords. To provide proper ground, a strap must be worn snug against bare skin. The
ground cord must be connected and fit snugly into the banana plug connector on the
grounding mat or workstation.
Heel straps/Toe straps/Boot straps
can be used at standing workstations and are
compatible with most types of shoes or boots. On conductive floors or dissipative floor mats,
use them on both feet with a maximum of one-megohm ± 10% resistance between the
operator and ground.
5.2.4 Grounding the Work Area
To prevent static damage at the work area, use the following precautions:
Cover the work surface with approved static-dissipative material. Provide a wrist strap
connected to the work surface and properly grounded tools and equipment.
Use static-dissipative mats, foot straps, or air ionizers to give added protection.
Handle electrostatic sensitive components, parts, and assemblies by the case or PCB
laminate. Handle them only at static-free work areas.
Turn off power and input signals before inserting and removing connectors or test
equipment.
Use fixtures made of static-safe materials when fixtures must directly contact dissipative
surfaces.
Keep work area free of nonconductive materials such as ordinary plastic assembly aids and
Styrofoam.
Use field service tools, such as cutters, screwdrivers, and vacuums, that are conductive.
5.2.5 Recommended Materials and Equipment
Materials and equipment that are recommended for use in preventing static electricity include:
Antistatic tape
Antistatic smocks, aprons, or sleeve protectors
Conductive bins and other assembly or soldering aids
Conductive foam
Conductive tabletop workstations with ground cord of one-megohm +/- 10% resistance
Static-dissipative table or floor mats with hard tie to ground
Field service kits
Static Shielding Protection Levels
Method
Voltage
Antistatic plastic
Carbon-loaded plastic
Metallized laminate
1,500
7,500
15,000