Data Cassettes
View all HP Visualize J5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Data Cassettes Media Life HP DDS data cassettes are currently specified to 2000 passes over any part of the tape under optimal environmental conditions (50% relative humidity, 22 degrees C). During a tape operation, any one area of the tape may have multiple passes over the heads. This translates into approximately 200 to 300 backups or restores. Under certain conditions, the life of your data cassette is less. Replace your data cassettes after 100 backups or restores if your operating conditions meet any of the following criteria: • The relative humidity in your operating environment is consis- tently less than 50%. • You know that the backup software you are using makes multi- ple passes over sections of the tape during backups or restores. • You notice that when you do backups and restores the tape stops and starts frequently. Cleaning the Tape Heads Clean the heads of your tape drive after every 25 hours of tape drive use or if the Media Wear (Caution) signal is displayed on the LED. NOTICE: Only use HP Cleaning Cassettes (HP92283K) to clean the tape heads. Do not use swabs or other means of cleaning the tape heads. Follow this procedure to clean the tape heads: 1. Insert the cleaning cassette into the drive. The tape automatically loads the cassette and cleans the heads. At the end of the cleaning cycle, the drive ejects the cassette. 2. Write the current date on the label on the cleaning cassette so that you know how many times you have used it. Discard the cleaning cassette after you have used it 25 times. 4-7