Brother International PR1055X Operation Manual - Page 179
screw with the Allen screwdriver, otherwise
View all Brother International PR1055X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
• Do not apply extreme force when loosening or tightening the needle set screw, otherwise the machine may be damaged. APPENDIX While holding the needle in place with your left hand, d tighten the needle set screw. Use the Allen screwdriver to turn the needle set screw clockwise. With the flat side of the needle toward the back of the c machine, insert the needle all the way up until it touches the needle bar stopper. Pass the needle through the hole in the presser foot, and then use the needle changing tool to lift up the needle. 1 Needle bar stopper 2 Needle 3 Flat side of needle 4 Needle changing tool Hold the needle changing tool and press the end of the needle changing tool 1 in to extend the needlemounting clamp 2. Attach the clamp to the needle, and then release the pressed area to clamp the needle. To unclamp the needle, press 1 again. CAUTION • Be sure to insert the needle in the needle bar chamber until it reaches the needle bar stopper and securely tighten the needle set screw with the Allen screwdriver, otherwise the needle may break or the machine may be damaged. • If the needle is not fully inserted, the hook of the automatic needle-threading mechanism 5 will not pass through the eye of the needle during automatic needle threading, and the hook may bend or the needle cannot be threaded. • If the hook of the automatic needle-threading mechanism is bent or damaged, contact your authorized Brother dealer. 1 End of the needle changing tool 2 Needle mounting clamp 177