Table 1-6. System Messages (continued) Message Causes Corrective Actions Keyboard fuse has failed. Keyboard fuse has failed. Faulty system board. Replace the keyboard. If the problem persists, the system board is faulty. See "Getting Help" on page 139. Manufacturing mode System is incorrectly detected configured. Memory address line Faulty or improperly Ensure that all memory failure at address, installed memory modules, modules are properly read value or faulty system board. installed. See expecting value "Troubleshooting System Memory double word logic failure at address, read value expecting value Memory" on page 115. If the problem persists, see "Getting Help" on page 139. Memory odd/even logic failure at start address to end address Memory write/read failure at address, read value expecting value Memory tests terminated by keystroke The spacebar was pressed Information only. during POST to terminate the memory test. About Your System 21