Dell PowerEdge T100 Hardware Owner's Manual - Page 25
SATA Port A/B/C/D - diskette 0 seek failure
View all Dell PowerEdge T100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions SATA port A/B/C/D hard disk drive failure Faulty drive. INT13 call failure from the drive. SATA port A/B/C/D hard disk drive auto-sensing error Ensure that the hard drive cables are properly connected. See "Troubleshooting a Hard Drive" on page 121. SATA Port A/B/C/D SATA Port A/B/C/D set as hard disk not found Auto, no disk installed. Run the System Setup program to correct the settings. See "Using the System Setup Program" on page 29. Sector not found Seek error Seek operation failed Faulty diskette or hard drive. See "Troubleshooting a USB Device" on page 108 or "Troubleshooting a Hard Drive" on page 121 for the appropriate drive installed in your system. Shutdown failure Shutdown test failure. Ensure that all memory modules are properly installed. See "Troubleshooting System Memory" on page 115. If the problem persists, see "Getting Help" on page 139. The amount of system memory has changed. Faulty memory module. Information only, if you have changed the memory configuration. See "Troubleshooting System Memory" on page 115. If the problem persists, see "Getting Help" on page 139. Faulty memory module. See "Troubleshooting System Memory" on page 115. If the problem persists, see "Getting Help" on page 139. About Your System 25