Dell PowerEdge T100 Hardware Owner's Manual - Page 23
Actual Link Width, PCIe Degraded Link - expansion slots
View all Dell PowerEdge T100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions Not a boot diskette The operating system is Insert a diskette that has a trying to boot from a bootable operating system. diskette that does not have a bootable operating system installed on it. Option ROM Checksum Error PCI device BIOS (Option Ensure that all appropriate ROM) checksum failure is cables are securely detected during shadowing. connected to the expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 124. PCIe Degraded Link Faulty or improperly Width Error: installed PCIe card. Embedded Bus#nn/Dev#nn/Funcn Expected Link Width is n Reseat the PCIe cards. See "Expansion Cards" on page 70. If the problem persists, see "Getting Help" on page 139. Actual Link Width is n PCIe Degraded Link Faulty or improperly Width Error: Slot n installed PCIe card in the Expected Link Width specified slot number. is n Actual Link Width is n Reseat the PCIe card in the specified slot number. See "Expansion Cards" on page 70. If the problem persists, see "Getting Help" on page 139. PCIe Training Faulty or improperly Error: Embedded installed PCIe card. Bus#nn/Dev#nn/Funcn Reseat the PCIe cards. See "Expansion Cards" on page 70. If the problem persists, see "Getting Help" on page 139. About Your System 23