HP Integrity Superdome 2 HP Integrity Superdome 2 Onboard Administrator User G - Page 130

Fans and cooling management, Thermal Subsystem screen

Page 130 highlights

Fans and cooling management Thermal Subsystem screen Fan subsystem status Row Description Thermal Subsystem Status Indicates the overall status of the fan subsystem. Possible values are Unknown, OK, Degraded, or Critical Error. Redundancy Indicates the redundancy status of the fans. Possible values are Redundant or Not Redundant Fan Location Rule The fan location rule indicates the proper location of the fans and the device bays that are supported. Fan status Column Fan Model Status Fan Speed Description The bay in the enclosure of the corresponding fan. The fan model name. The overall status of the fan. Possible values are Unknown, OK, Degraded, Failed, and Absent. Fan speed as a percentage of maximum RPM. When a fan module fails, the remaining fans automatically compensate by adjusting fan speeds. You can view the status of each fan by selecting the fan bay either through the tree navigation or the graphical navigation view. The Fan Information screen provides information about the overall status, the name, the amount of power consumed in watts, the spare part number, and the serial number. The Fan Information screen also includes diagnostic information such as internal data 130 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Fans and cooling management
Thermal Subsystem screen
Fan subsystem status
Description
Row
Indicates the overall status of the fan subsystem. Possible values are Unknown, OK,
Degraded, or Critical Error.
Thermal Subsystem Status
Indicates the redundancy status of the fans. Possible values are Redundant or Not Redundant
Redundancy
The fan location rule indicates the proper location of the fans and the device bays that are
supported.
Fan Location Rule
Fan status
Description
Column
The bay in the enclosure of the corresponding fan.
Fan
The fan model name.
Model
The overall status of the fan. Possible values are Unknown, OK, Degraded, Failed, and
Absent.
Status
Fan speed as a percentage of maximum RPM.
Fan Speed
When a fan module fails, the remaining fans automatically compensate by adjusting fan speeds.
You can view the status of each fan by selecting the fan bay either through the tree navigation or
the graphical navigation view. The Fan Information screen provides information about the overall
status, the name, the amount of power consumed in watts, the spare part number, and the serial
number. The Fan Information screen also includes diagnostic information such as internal data
130
Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices