Power Management screen, If redundancy mode is set to Redundant, AC Redundant
View all HP Integrity Superdome 2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Power Management screen NOTE: If redundancy mode is set to Redundant, AC Redundant, or Power Supply Redundant, and power redundancy is lost, then you must either add additional power supplies or change the redundancy mode setting in the Onboard Administrator to restore Power Subsystem status. One upper and one lower power supply must always be installed and operational. See the Insight Display for corrective steps. The Superdome 2 enclosure power management system enables you to customize the configuration of the enclosure. You can select from the various modes on the Onboard Administrator Power Management screen. The power modes are explained in the following table: Mode Redundant Insight Display name Redundant Description For dc power supplies only. In this configuration, N upper and N lower power supplies are used to provide power and N upper and N lower power supplies are used to provide redundancy (where N can equal 1, 2, or 3). Up to three upper and three lower power supplies can fail without causing the enclosure to fail. When correctly 52 First Time Setup Wizard