HP Integrity Superdome 2 HP Integrity Superdome 2 Onboard Administrator User G - Page 156

Thermal Subsystem information, Fan information, When a fan module fails

Page 156 highlights

Thermal Subsystem information Item Description Thermal Subsystem Status Indicates the overall status of the fan subsystem. Possible values are Unknown, OK, Degraded, or Critical Error. Redundancy Indicates the redundancy status of the fans. Possible values are Redundant or Not Redundant Ambient Temperature The temperature of the IOX enclosure in degrees Celsius and Fahrenheit. Fans Good The total number of fans functioning with OK status in the IOX enclosure. Fans Wanted The minimum number of fans required for optimum cooling. Fans Needed The minimum number of fans required to ensure adequate cooling. Fan information Item Fan Status Fan Speed Description The bay in the enclosure of the corresponding fan. The overall status of the fan. Possible values are Unknown, OK, Degraded, Failed, and Absent. Fan speed as a percentage of maximum RPM. When a fan module fails, the remaining fans automatically compensate by adjusting fan speeds. To update information on this page, click the Refresh button. 156 HP Integrity Superdome 2 IOX enclosures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Thermal Subsystem information
Description
Item
Indicates the overall status of the fan subsystem. Possible values are Unknown, OK,
Degraded, or Critical Error.
Thermal Subsystem Status
Indicates the redundancy status of the fans. Possible values are Redundant or Not
Redundant
Redundancy
The temperature of the IOX enclosure in degrees Celsius and Fahrenheit.
Ambient Temperature
The total number of fans functioning with OK status in the IOX enclosure.
Fans Good
The minimum number of fans required for optimum cooling.
Fans Wanted
The minimum number of fans required to ensure adequate cooling.
Fans Needed
Fan information
Description
Item
The bay in the enclosure of the corresponding fan.
Fan
The overall status of the fan. Possible values are Unknown, OK, Degraded, Failed, and
Absent.
Status
Fan speed as a percentage of maximum RPM.
Fan Speed
When a fan module fails, the remaining fans automatically compensate by adjusting fan speeds.
To update information on this page, click the
Refresh
button.
156
HP Integrity Superdome 2 IOX enclosures