HP LH4r HP NetRAID-4M Installation Guide - Page 112

Communications, Use_IP, IP_PORT, IPX_SOCKET, Client_timeout

Page 112 highlights

Hewlett-Packard NetRAID-4M Controller Installation Guide Communications The communications section provides switches that control how communication will be configured. The communication section will contain the following switches: s Use_IP - if this switch is set to TRUE then the HP NetRAID4M Remote Agent will attempt to use IP as a communications protocol. s IP_PORT - this switch will specify, in decimal, the IP port that will be used for communications. This may be helpful to users that are trying to access the controller through a firewall. The IP_PORT is specified as a four-octet address, for example, 128.10.2.30. s Use_IPX - if this switch is set to TRUE then the HP NetRAID4M Remote Agent will attempt to use IPX as a communications protocol. s IPX_SOCKET - this switch will specify, in decimal, the IPX socket that will be used for communications. This may be helpful to users that are trying to access the controller through a firewall. The IPX_SOCKET is specified as a hexadecimal address, for example, 4640E44D.000000000001. s Client_timeout - this switch specifies, in seconds, the amount of time that the software will allow to expire before closing communications with the client. ❒ C-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

C-6
Hewlett-Packard NetRAID-4M Controller Installation Guide
Communications
The communications section provides switches that control how
communication will be configured. The communication section will
contain the following switches:
Use_IP
if this switch is set to TRUE then the HP NetRAID-
4M Remote Agent will attempt to use IP as a communications
protocol.
IP_PORT
this switch will specify, in decimal, the IP port
that will be used for communications. This may be helpful to
users that are trying to access the controller through a firewall.
The IP_PORT is specified as a four-octet address, for example,
128.10.2.30
.
Use_IPX
if this switch is set to TRUE then the HP NetRAID-
4M Remote Agent will attempt to use IPX as a communications
protocol.
IPX_SOCKET
this switch will specify, in decimal, the IPX
socket that will be used for communications. This may be
helpful to users that are trying to access the controller through
a firewall. The IPX_SOCKET is specified as a hexadecimal
address, for example,
4640E44D.000000000001
.
Client_timeout
this switch specifies, in seconds, the amount
of time that the software will allow to expire before closing
communications with the client.