Panasonic HPX500 Operating Instructions - Page 65

Outputting the time code externally, External synchronisation of

Page 65 highlights

Chapter 4 Adjustments and Settings for Recording To unlock the externally locked time code Discontinue external time code supply, then position the TCG switch at [R-RUN]. Cautions in switching the power source from battery to external power supply Connect the DC IN socket with the external power supply before removing the battery pack, in order to keep the time code generator energized. If the battery pack is removed first, there is no guarantee that the time code will stay externally locked. External synchronisation of the camera when the time code is externally locked When the time code is externally locked, the reference video signals input through the GENLOCK IN connector gen-lock the camera. • To externally lock the AG-HPX500P/E, as the master device, with more than one unit, the mode must be the same as that of the camera. Note that in a system using both interlaced and progressive scanning, there may be breaks in the video and time code. • Note that switching to MCR mode will disrupt GENLOCK synchronization resulting in loss of image stability. • When the 24P or 24PA is selected and the time code is externally locked, be sure to input a non-drop frame time code. The time code cannot be externally locked when drop frame mode is selected. When the time code is externally locked, the video may be distorted, but this is because of the 5-frame adjustment and not a malfunction. Outputting the time code externally To output time code from the camera's TC OUT connector to a VTR or other recording device in sync with camera picture or playback picture, set the setting menu TC VIDEO SYNCRO (OUTPUT SEL) to VIDEO OUT. Set also the setting menu GL SELECT (OTHER FUNCTIONS) to SDI or COMPOSITE to suit video output. AG-HPX500P/E SDI OUT or VIDEO OUT TC OUT TC IN TC VIDEO SYNCRO setting: VIDEO OUT VIDEO IN SDI IN HD SDI IN VTR, etc. When the setting menu TC VIDEO SYNCRO is set to VIDEO OUT, the time code is output via TC OUT in tune with VIDEO OUT delay. 65 Setting Time Data

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

65
Setting Time Data
Chapter 4 Adjustments and Settings for Recording
To unlock the externally locked time
code
Discontinue external time code supply, then position
the TCG switch at [R-RUN].
Cautions in switching the power
source from battery to external power
supply
Connect the DC IN socket with the external power
supply before removing the battery pack, in order to
keep the time code generator energized. If the battery
pack is removed first, there is no guarantee that the
time code will stay externally locked.
External synchronisation of the
camera when the time code is
externally locked
When the time code is externally locked, the reference
video signals input through the GENLOCK IN
connector gen-lock the camera.
<Notes>
To externally lock the AG-HPX500P/E, as the master
device, with more than one unit, the mode must be the
same as that of the camera. Note that in a system using
both interlaced and progressive scanning, there may
be breaks in the video and time code.
Note that switching to MCR mode will disrupt
GENLOCK synchronization resulting in loss of image
stability.
When the 24P or 24PA is selected and the time code
is externally locked, be sure to input a non-drop frame
time code. The time code cannot be externally locked
when drop frame mode is selected. When the time code
is externally locked, the video may be distorted, but
this is because of the 5-frame adjustment and not a
malfunction.
Outputting the time code
externally
To output time code from the camera’s TC OUT
connector to a VTR or other recording device in sync
with camera picture or playback picture, set the setting
menu TC VIDEO SYNCRO (OUTPUT SEL) to VIDEO
OUT.
Set also the setting menu GL SELECT (OTHER
FUNCTIONS) to SDI or COMPOSITE to suit video
output.
VTR, etc.
TC OUT
AG-HPX500P/E
TC VIDEO SYNCRO
setting: VIDEO OUT
VIDEO IN
SDI IN
HD SDI IN
SDI OUT
or
VIDEO OUT
TC IN
<Note>
When the setting menu TC VIDEO SYNCRO is set to
VIDEO OUT, the time code is output via TC OUT in tune
with VIDEO OUT delay.