Rising and Falling, Falling Threshold
View all Dell PowerConnect 5548 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 630 highlights
- Sample Type - Select the sampling method for the selected variable and comparing the value against the thresholds. The possible options are: • Delta - Subtracts the last sampled value from the current value. The difference in the values is compared to the threshold. • Absolute - Compares the values directly with the thresholds at the end of the sampling interval. - Rising Threshold (0-2147483647) - Enter the rising counter value that triggers the rising event alarm. - Rising Event - Select one of the previously-defined events. - Falling Threshold (0-2147483647) - Enter the falling counter value that triggers the falling event alarm. - Falling Event - Select one of the previously-defined events. - Startup Alarm - Select the trigger that activates the alarm. The possible options are: • Rising Alarm - A rising counter value triggers the alarm • Falling Alarm - A falling counter value triggers the alarm. • Rising and Falling - Both rising and falling counter values trigger the alarm. - Interval (1-2147483647) - Enter the alarm interval time in seconds. This is the interval in seconds over which the data is sampled and compared with the rising and falling thresholds. - Owner - Enter the name of the user or network management system that receives the alarm. 630 Dell PowerConnect 55xx Systems User Guide