Intel S2600GZ S2600GZ/GL - Page 114
BMC Boot/Reset Status LED Indicators - motherboard
View all Intel S2600GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
Intel® Server Board S2600GZ/GL TPS Light Guided Diagnostics Color Amber State Solid on Criticality Critical, nonrecoverable - System is halted Description DDR3 DIMM when the system is operating in a non-redundant mode Fatal alarm - system has failed or shutdown: CPU CATERR signal asserted MSID mismatch detected (CATERR also asserts for this case). CPU 1 is missing CPU Thermal Trip No power good - power fault DIMM failure when there is only 1 DIMM present and hence no good memory present. Runtime memory uncorrectable error in non-redundant mode. DIMM Thermal Trip or equivalent SSB Thermal Trip or equivalent CPU ERR2 signal asserted BMC\Video memory test failed. (Chassis ID shows blue/solid-on for this condition) Both uBoot BMC FW images are bad. (Chassis ID shows blue/solidon for this condition) 240VA fault Fatal Error in processor initialization: Processor family not identical Processor model not identical Processor core/thread counts not identical Processor cache size not identical Unable to synchronize processor frequency Unable to synchronize QPI link frequency 10.3 BMC Boot/Reset Status LED Indicators During the BMC boot or BMC reset process, the System Status LED and System ID LED are used to indicate BMC boot process transitions and states. A BMC boot will occur when AC power is first applied to the system. A BMC reset will occur after: a BMC FW update, upon receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following table defines the LED states during the BMC Boot/Reset process. Table 46. BMC Boot/Reset Status LED Indicators BMC Boot/Reset State BMC/Video memory test failed Both Universal Bootloader (uBoot) images bad Chassis ID LED Solid Blue Solid Blue BMC in u-Boot Blink Blue 3Hz BMC Booting Linux Solid Blue End of BMC boot/reset process. Normal system operation Off Status LED Solid Amber Solid Amber Blink Green 1Hz Solid Green Solid Green Comment Nonrecoverable condition. Contact your Intel® representative for information on replacing this motherboard. Nonrecoverable condition. Contact your Intel® representative for information on replacing this motherboard. Blinking green indicates degraded state (no manageability), blinking blue indicates u-Boot is running but has not transferred control to BMC Linux. Server will be in this state 6-8 seconds after BMC reset while it pulls the Linux image into flash. Solid green with solid blue after an AC cycle/BMC reset, indicates that the control has been passed from u-Boot to BMC Linux itself. It will be in this state for ~10-~20 seconds. Indicates BMC Linux has booted and manageability functionality is up and running. Fault/Status LEDs operate as per usual. Revision 1.1 101 Intel order number G24881-004