Intel S2600GZ S2600GZ/GL - Page 114

BMC Boot/Reset Status LED Indicators - motherboard

Page 114 highlights

Intel® Server Board S2600GZ/GL TPS Light Guided Diagnostics Color Amber State Solid on Criticality Critical, nonrecoverable - System is halted Description DDR3 DIMM when the system is operating in a non-redundant mode Fatal alarm - system has failed or shutdown: CPU CATERR signal asserted MSID mismatch detected (CATERR also asserts for this case). CPU 1 is missing CPU Thermal Trip No power good - power fault DIMM failure when there is only 1 DIMM present and hence no good memory present. Runtime memory uncorrectable error in non-redundant mode. DIMM Thermal Trip or equivalent SSB Thermal Trip or equivalent CPU ERR2 signal asserted BMC\Video memory test failed. (Chassis ID shows blue/solid-on for this condition) Both uBoot BMC FW images are bad. (Chassis ID shows blue/solidon for this condition) 240VA fault Fatal Error in processor initialization: Processor family not identical Processor model not identical Processor core/thread counts not identical Processor cache size not identical Unable to synchronize processor frequency Unable to synchronize QPI link frequency 10.3 BMC Boot/Reset Status LED Indicators During the BMC boot or BMC reset process, the System Status LED and System ID LED are used to indicate BMC boot process transitions and states. A BMC boot will occur when AC power is first applied to the system. A BMC reset will occur after: a BMC FW update, upon receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following table defines the LED states during the BMC Boot/Reset process. Table 46. BMC Boot/Reset Status LED Indicators BMC Boot/Reset State BMC/Video memory test failed Both Universal Bootloader (uBoot) images bad Chassis ID LED Solid Blue Solid Blue BMC in u-Boot Blink Blue 3Hz BMC Booting Linux Solid Blue End of BMC boot/reset process. Normal system operation Off Status LED Solid Amber Solid Amber Blink Green 1Hz Solid Green Solid Green Comment Nonrecoverable condition. Contact your Intel® representative for information on replacing this motherboard. Nonrecoverable condition. Contact your Intel® representative for information on replacing this motherboard. Blinking green indicates degraded state (no manageability), blinking blue indicates u-Boot is running but has not transferred control to BMC Linux. Server will be in this state 6-8 seconds after BMC reset while it pulls the Linux image into flash. Solid green with solid blue after an AC cycle/BMC reset, indicates that the control has been passed from u-Boot to BMC Linux itself. It will be in this state for ~10-~20 seconds. Indicates BMC Linux has booted and manageability functionality is up and running. Fault/Status LEDs operate as per usual. Revision 1.1 101 Intel order number G24881-004

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264

Intel® Server Board S2600GZ/GL TPS
Light Guided Diagnostics
Revision 1.1
Intel order number G24881-004
101
Color
State
Criticality
Description
DDR3 DIMM when the system is operating in a non-redundant mode
Amber
Solid on
Critical, non-
recoverable
System is halted
Fatal alarm
system has failed or shutdown:
CPU CATERR signal asserted
MSID mismatch detected (CATERR also asserts for this case).
CPU 1 is missing
CPU Thermal Trip
No power good
power fault
DIMM failure when there is only 1 DIMM present and hence no good
memory present.
Runtime memory uncorrectable error in non-redundant mode.
DIMM Thermal Trip or equivalent
SSB Thermal Trip or equivalent
CPU ERR2 signal asserted
BMC\Video memory test failed. (Chassis ID shows blue/solid-on for
this condition)
Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid-
on for this condition)
240VA fault
Fatal Error in processor initialization:
Processor family not identical
Processor model not identical
Processor core/thread counts not identical
Processor cache size not identical
Unable to synchronize processor frequency
Unable to synchronize QPI link frequency
10.3
BMC Boot/Reset Status LED Indicators
During the BMC boot or BMC reset process, the System Status LED and System ID LED are
used to indicate BMC boot process transitions and states.
A BMC boot will occur when AC
power is first applied to the system. A BMC reset will occur after: a BMC FW update, upon
receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following
table defines the LED states during the BMC Boot/Reset process.
Table 46. BMC Boot/Reset Status LED Indicators
BMC Boot/Reset State
Chassis
ID LED
Status
LED
Comment
BMC/Video memory test failed
Solid
Blue
Solid
Amber
Nonrecoverable condition. Contact your Intel
®
representative for information on replacing this
motherboard.
Both Universal Bootloader (u-
Boot) images bad
Solid
Blue
Solid
Amber
Nonrecoverable condition. Contact your Intel
®
representative for information on replacing this
motherboard.
BMC in u-Boot
Blink
Blue
3Hz
Blink
Green
1Hz
Blinking green indicates degraded state (no manageability),
blinking blue indicates u-Boot is running but has not
transferred control to BMC Linux. Server will be in this state
6-8 seconds after BMC reset while it pulls the Linux image
into flash.
BMC Booting Linux
Solid
Blue
Solid
Green
Solid green with solid blue after an AC cycle/BMC reset,
indicates that the control has been passed from u-Boot to
BMC Linux itself. It will be in this state for ~10-~20 seconds.
End of BMC boot/reset process.
Normal system operation
Off
Solid
Green
Indicates BMC Linux has booted and manageability
functionality is up and running. Fault/Status LEDs operate
as per usual.