Intel S2600GZ S2600GZ/GL - Page 190
Power off, minutes, Disabled
View all Intel S2600GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 190 highlights
Intel® Server Board S2600GZ/GL TPS BIOS Setup Utility 11. OS Boot Watchdog Timer Policy Option Values: Power off Reset Help Text: If the OS watchdog timer is enabled, this is the system action taken if the watchdog timer expires. [Reset] - System performs a reset. [Power Off] - System powers off. Comments: This option is grayed out and unavailable when the O/S Boot Watchdog Timer is disabled. Back to [Server Management Screen] 12. OS Boot Watchdog Timer Timeout Option Values: 5 minutes 10 minutes 15 minutes 20 minutes Help Text: If the OS watchdog timer is enabled, this is the timeout value BIOS will use to configure the watchdog timer. Comments: This option is grayed out and unavailable when the O/S Boot Watchdog Timer is disabled. Back to [Server Management Screen] 13. Plug & Play BMC Detection Option Values: Enabled Disabled Help Text: If enabled, the BMC will be detectable by OSes which support plug and play loading of an IPMI driver. Do not enable this option if your OS does not support this driver. Comments: This option controls whether the OS Server Management Software will be able to find the BMC and automatically load the correct IPMI support software for it. If your OS does not support Plug & Play for the BMC, you will not have the correct IPMI driver software loaded. Back to [Server Management Screen] EuP LOT6 Off-Mode Option Values: Enabled Disabled Help Text: Enable/disable Ecodesign EuP LOT6 "Deep Sleep" Off-Mode for near-zero energy use when powered off. Revision 1.1 177 Intel order number G24881-004