Intel S2600GZ S2600GZ/GL - Page 232
Intel® Server Board S2600GZ/GL TPS, Appendix B: Integrated BMC Sensor Tables, Revision 1.1, Intel
View all Intel S2600GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 232 highlights
Intel® Server Board S2600GZ/GL TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor # Button Sensor (Button) 09h BMC Watchdog 0Ah Voltage Regulator Watchdog (VR Watchdog) 0Bh Fan RedundancyNote1 0Ch (Fan Redundancy) SSB Thermal Trip (SSB Therm Trip) 0Dh Platform Applicability All All All Chassisspecific All Sensor Type Event/Readi Event Offset Triggers ng Type Button/Switch 14h Mgmt System Health 28h Voltage 02h Fan 04h Temperature 01h Sensor Specific 6Fh Digital Discrete 03h Digital Discrete 03h Generic 0Bh Digital Discrete 03h 00 - Power Button 02 - Reset Button 01 - State Asserted 01 - State Asserted 00 - Fully redundant 01 - Redundancy lost 02 - Redundancy degraded 03 - Non-redundant: Sufficient resources. Transition from redundant 04 - Non-redundant: Sufficient resources. Transition from insufficient. 05 - Non-redundant: insufficient resources. 06 - Non-Redundant: degraded from fully redundant. 07 - Redundant degraded from nonredundant 01 - State Asserted Contrib. To System Status OK Degraded Fatal OK Degraded Degraded Degraded Degraded Non-Fatal Degraded Degraded Fatal Assert/ De- assert Readable Value/Of fsets AS _ As - As and - De As and - De As and - De Event Data Trig Offset Trig Offset Trig Offset Trig Offset Trig Offset Rearm A A M A M Standby X X - X Revision 1.1 219 Intel order number G24881-004