Intel S2600GZ S2600GZ/GL - Page 243
Appendix C: Management Engine Generated SEL Event Messages, Intel® Server Board S2600GZ/GL TPS,
View all Intel S2600GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 243 highlights
Appendix C: Management Engine Generated SEL Event Messages Intel® Server Board S2600GZ/GL TPS Byte 7 - Event Data 3 = Table 57. Node Manager Health Event Node Manager Health Event Request Byte 1 - EvMRev =04h (IPMI2.0 format) Byte 2 - Sensor Type =DCh (OEM) Byte 3 - Sensor Number (Node Manager Health sensor) Byte 4 - Event Dir | Event Type [0:6] - Event Type = 73h (OEM) [7] - Event Dir =0 Assertion Event Byte 5 - Event Data 1 [0:3] - Health Event Type =02h - Sensor Node Manager [4:5]=10b - OEM code in byte 3 [6:7]=10b - OEM code in byte 2 Byte 6 - Event Data 2 [0:3] - Domain Id (Currently, supports only one domain, Domain 0) [4:7] - Error type =0-9 - Reserved =10 - Policy Misconfiguration =11 - Power Sensor Reading Failure =12 - Inlet Temperature Reading Failure =13 - Host Communication error =14 - Real-time clock synchronization failure =15 - Reserved Byte 7 - Event Data 3 if error indication = 10 if error indication = 11 if error indication = 12 Otherwise set to 0. 230 Revision 1.1 Intel order number G24881-004