Table 64. Integrated BMC Beep Codes
View all Intel S2600GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 255 highlights
Appendix E: POST Code Errors Intel® Server Board S2600GZ/GL TPS not sounded continuously. Codes that are common across all Intel server boards and systems that use same generation chipset are listed in the following table. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit. Table 64. Integrated BMC Beep Codes Code 1-5-2-1 1-5-2-4 1-5-4-2 1-5-4-4 1-5-1-2 1-5-1-4 Reason for Beep No CPUs installed or first CPU socket is empty. MSID Mismatch Power fault Power control fault (power good assertion timeout). VR Watchdog Timer sensor assertion Power Supply Status Associated Sensors CPU1 socket is empty, or sockets are populated incorrectly CPU1 must be populated before CPU2. MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities. DC power unexpectedly lost (power good dropout) - Power unit sensors report power unit failure offset Power good assertion timeout - Power unit sensors report soft power control failure offset VR controller DC power on sequence was not completed in time. The system does not power on or unexpectedly powers off and a Power Supply Unit (PSU) is present that is an incompatible model with one or more other PSUs in the system. 242 Revision 1.1 Intel order number G24881-004